Resetting the PowerCage 401 Enclosure with the Reset Button
NOTE:
The front panel
Reset
button only resets the enclosure and not the boards
installed in the slots.
There are three reset modes (numbered 1, 4, and 5 for the sake of comparison with Extron
IPL products) that you can access by pressing the
Reset
button on the front panel. The
Reset
button is recessed, so use a pointed stylus, ballpoint pen, or Extron Tweeker to
PowerCage 401 Reset Mode Summary
table on the next page).
CAUTION:
Review the reset modes carefully. Using the wrong reset mode may result
in unintended loss of flash memory programming, port reassignment, or processor
reboot.
ATTENTION :
Étudier de près les différents modes de réinitialisation. Appliquer
le mauvais mode de réinitialisation peut causer une perte inattendue de la
programmation de la mémoire flash, une reconfiguration des ports ou une
réinitialisation du contrôleur.
NOTE:
The reset modes listed in the table close all open IP and Telnet connections and
close all sockets. Also, each mode is a separate function, not a continuation from
mode 1 to mode 5.
RESE
T
RESE
T
RESE
T
RESE
T
Release, then
immediately
press and release again. Reset
LED flashes in confirmation.
Modes 4, and 5
Press and
hold
the
Reset
button.
Mode 1
Reset LED blinks
once,
twice, or three times
.
Press and
hold
for
6 or 9 seconds.
Apply Power
1
2
RESE
T
Release
Reset
button.
Figure 9.
Resetting the PowerCage 401
NOTES:
•
After a mode 1 reset is performed, update the firmware for the PowerCage 401 to
the latest version. Do not operate the firmware version that results from the mode
1 reset. If the factory default firmware is to be used, that version must be uploaded
again.
•
If you do not want to update firmware, or you performed a mode 1 reset by
mistake, cycle power to the device to return to the firmware version that was
running before the mode 1 reset. Use the
0Q
SIS command to confirm that the
factory default firmware is no longer running (look for the asterisk [*] following the
version number)
.
9
PowerCage 401 Enclosure • Operation
14
Содержание PowerCage 401
Страница 8: ...PowerCage 401 Enclosure Contents viii...