Matrix Software, cont’d
MTPX Plus Twisted Pair Matrix Switchers • Matrix Software
5-24
Optimizing the Video
Each TP input has a level and peaking adjustment. Most MTP transmitters and half
of the MTPX Plus TP outputs have a pre-peaking feature. TP inputs and outputs
have skew adjustments. Set these adjustable features as follows for the best image
quality:
N
For all of the settings in this section (with the exception of the
transmitter’s
Pre-Peak switch in step
1
), see the MTPX Pictures settings and MTPX
configuration settings menu items in “Tools menu”, on page 5-19.
These settings can also be made using SIS commands or the built-in HTML
pages. See chapter 4, “Programmer’s Guide” and chapter 6, “HTML
Operation”.
N
Unless the TP cables are changed, these adjustments should need to be made
only once, during installation.
Before you start optimizing,
set all input level and peaking, input and output
skew, and output pre-peak settings to either zero or off.
MTP transmitter Pre-Peak selection
For inputs from MTP T 15HD products
only
—
If the cable between the MTP
transmitter and the MTPX Plus is > 300', turn the transmitter’s Pre-Peak switch on.
For shorter cables, turn the switch off.
MTPX level/peaking setting
The simplest and surest way to set the input level/peaking is to use the included
MTP signal generator and the Auto-calibration utility within the Matrix Switchers
Control Program as follows:
N
To manually set the input level/peaking, proceed to step
1
.
Disconnect the power and RJ-45 cables at the MTP transmitter connected to
the input to be adjusted.
2
.
Connect the two cables to the included MTP signal generator.
3
.
If the input cable between the transmitter and the MTPX Plus is longer than
300' (90 m), place the MTP signal generator’s Pre-Peak switch on (figure 5-20).
Pre-Peak on (up) (shown)
Pre-Peak off (down)
Power LED
Figure 5-20 — MTP signal generator
4
.
In the Matrix Switchers Control Program, click
Tools
>
MTPX Picture settings
to open the MTPX Picture Settings window (figure 5-16 on page 5-20).
5
.
Click the
Auto-Calibrate Level/Peaking
button.
After a few moments, the program reports whether or not the
calibration succeeded and the original and new settings for the
input Pre-Peaking adjustment.
Содержание MTPX Plus Series
Страница 1: ...MTPX Plus Series Mini Twisted Pair Matrix Switcher 68 1383 01 Rev B 09 08 ...
Страница 4: ......
Страница 20: ...Introduction cont d MTPX Plus Twisted Pair Matrix Switchers Introduction 1 10 ...
Страница 32: ...Installation cont d MTPX Plus Twisted Pair Matrix Switchers Installation 2 12 ...
Страница 92: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 60 ...
Страница 94: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 62 ...
Страница 171: ...MTPX Plus Twisted Pair Matrix Switchers A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer ...
Страница 178: ...Ethernet Connection cont d MTPX Plus Twisted Pair Matrix Switchers Ethernet Connection A 8 ...
Страница 187: ...B 9 MTPX Plus Twisted Pair Matrix Switchers Reference Information Button label blanks 16 button strips ...
Страница 188: ...Reference Information cont d MTPX Plus Twisted Pair Matrix Switchers Reference Information B 10 ...