background image

User Guide

MPA 601-70V and 
MPA 601-100V

Power Amplifiers

60W Analog Power Amplifiers

68-2512-01 Rev. B

01 17

Содержание MPA 601-100V

Страница 1: ...User Guide MPA 601 70V and MPA 601 100V Power Amplifiers 60W Analog Power Amplifiers 68 2512 01 Rev B 01 17...

Страница 2: ...encia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la pr sence l int rieur...

Страница 3: ...Inline IP Intercom IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NetPA PlenumVault PoleVault PowerCage PURE3 Quantum SoundField SpeedMount SpeedSwitch System INTEGRATOR TeamWork TouchLink...

Страница 4: ...to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help In order to maintain compliance with FCC regulations...

Страница 5: ...mat riels NOTE A note draws attention to important information TIP A tip provides a suggestion to make working with the application easier Specifications Availability Product specifications are avail...

Страница 6: ...tion 10 Front Panel Features 10 Setting Input Level 10 Setting Bass and Treble 11 Remote Control Operation 11 Controlling Multiple Amplifiers with One Remote Controller 12 Control Options 13 Troublesh...

Страница 7: ...ns Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with a dry cloth Do not block any ventilation openings Install in accordance with t...

Страница 8: ...that have restricted space concerns or limited rack space but require enough power for a small to medium distributed audio system As such the MPA 601 can be used in small racks within a credenza with...

Страница 9: ...s to full power status in less than one second upon signal detection Defeatable auto standby timer Automatic timed standby feature can be disabled for sensitive applications that require uninterrupted...

Страница 10: ...ER 12 V 1 3A MAX SUM MED R L V C G 10 V 50 mA ST AN DB Y TIMER OF F G R INPUTS Extron SF 3CT LP Full Range Ceiling Speakers Extron MPA 601 Mini Power Amplifier Laptop Room PC Blu ray Disc Projector Ex...

Страница 11: ...tor G Remote Input Connector D Balanced or Unbalanced Audio Input Connector H Speaker Output Connection Figure 2 MPA 601 70V and MPA 601 100V Rear Panel Connections A Power Connector A 36W desktop pow...

Страница 12: ...que le produit final Suitable for use in environmental air space in accordance with Section 300 22 C of the National Electrical Code and Sections 2 128 12 010 3 and 12 100 of the Canadian Electrical...

Страница 13: ...posed wires may touch causing a short circuit between them Any shorter and the wires can be easily pulled out even if tightly fastened by the captive screws La longueur id ale est de 5 mm 3 16 inches...

Страница 14: ...h s par les vis captives Do not tin the wires Tinned wire does not hold its shape and can become loose over time Ne pas tamer les c bles Les c bles tam s ne sont pas aussi bien fix s dans les terminai...

Страница 15: ...to 60W for a 100V distributed sound system CLASS 2 WIRING 70V OUTPUT CLASS 2 WIRING 100V OUTPUT Figure 9 MPA Speaker Output Connector ATTENTION Do not ground or short the speaker outputs as this will...

Страница 16: ...e amount of attenuation applied to the input signal C Bass Potentiometer Adjusts the amount of attenuation or gain applied to the bass frequencies of the input signal 10 dB 100 Hz D Treble Potentiomet...

Страница 17: ...h as the provided Extron Tweeker adjust the TREBLE potentiometer to increase or decrease the treble shelving 10 dB at 10 kHz and above Remote Control Operation Options for remote control include the E...

Страница 18: ...tput can be achieved with a contact closure button attached between the Vol Mute and Ground pin of the first MPA in the chain To regulate multiple amplifiers with a single remote controller 1 Attach a...

Страница 19: ...J Z X C V B N M K L control shift caps lock tab esc F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 F17 F18 F19 alt option command delete fn home clear enter 8 5 2 7 0 4 1 9 6 3 page up page do...

Страница 20: ...the remote port Green or Amber Slow to exit standby mode when a signal is present The input signal may be too weak Raise the input level Amber DC Fault is detected on either channel The unit does not...

Страница 21: ...supply provided with it is not Cables to and from the amplifier must also be plenum rated The power supply must not be placed in the plenum space The DC power cord provided with the unit is not plenu...

Страница 22: ...ings when addressing this concern Reliable earthing grounding Maintain reliable grounding of rack mounted equipment Pay particular attention to supply connections other than direct connections to the...

Страница 23: ...pe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia Pte Ltd 135 Joo Seng Road 04 01 PM Industrial Bldg...

Отзывы: