Extron electronics MLC Plus 84 EU Скачать руководство пользователя страница 1

1

IMPO

RTAN

T:

Go to ww

w.extr

on.com 

for the complete

 

user guide

, installation instructions,

 and 

specifications bef

ore connecting the 

product to the po

wer sour

ce.

MLC Plus 84 EU and MLC Plus 84 MK •  
Setup Guide

The Extron MLC Plus 84 EU and 
MLC Plus 84 MK  
MediaLink

®

 Controllers with 

IP Link

®

 Pro integrate Ethernet 

connection into AV systems to allow 
users to remotely control, monitor, and 
troubleshoot AV equipment, including 
display devices and switchers. Each 
controller includes an embedded 
web server and support for Power 
over Ethernet (PoE). It also includes 
ports for bidirectional serial control, 
IR output, relays, digital input, and 
volume control.

Figure 1. 

MLC Plus 84 MK Front Panel

The MLC Plus 84 EU fits most standard two-gang European wall boxes. The MLC Plus 84 MK fits most standard two-gang 
MK-type wall boxes. These two models are identical except for the EU- or MK-specific wallplates and mounting hardware. 
Features, connectors, and operation are the same for both models.
This guide provides instructions for an experienced installer to install an MLC Plus 84 Series controller and to create a basic 
configuration. Use Extron Toolbelt software to discover and manage the MLC Plus controller and other Extron control products. 
Configure the controller using Extron Global Configurator

®

 software running in Global Configurator Professional (GC Professional) 

or Global Configurator Plus (GC Plus) mode. The MLC integrates with Extron GlobalViewer

®

 Enterprise (GVE) software and the 

Extron Control apps for remote control applications. Global Configurator and other useful software applications are available at 

www.extron.com

.

Installation

Step 1: Get Ready

Use the following check list to prepare for the installation.

 

…

Download and install the latest version of the following:

• 

Toolbelt software

 — for discovering the controller and other control products on the network, for managing core 

settings, and for upgrading firmware if the need arises.

• 

Global Configurator (GC) software

 — for configuring the controller.

• 

IP Link Pro device drivers

 — for use with GC, to make control of AV possible.

All are avail able from 

www.extron.com

 (see 

Locating Software, Firmware, and Driver Files on the Extron Website

 on page 13).

 

…

Obtain network information for the unit from the network administrator. You need the following details for each IP Link Pro device:

 

…

DHCP setting (on or off)

 

…

Subnet mask

 

…

User name

 

…

Device (MLC Plus 84) IP address

 

…

Gateway IP address

 

…

Passwords

 

…

Write down the MAC address of each IP Link Pro device (such as the MLC Plus 84) to be used.

 

…

Obtain model names and setup information for devices the MLC Plus 84 will control.

 

…

Each controller comes with a factory-installed Secure Sockets Layer (SSL) security certificate. If you intend to install a different 
SSL certificate, contact your IT department to obtain the certificate or for instructions on how to obtain one. See “Secure 
Sockets Layer (SSL) Certificates” in the 

MLC Plus 84 Series User Guide

 for requirements and guidelines regarding SSL 

certificates.

Figure 2. 

MLC Plus 84 EU Front Panel

Rev. C, 09/2018:  

Added mention 
of stand-alone 
Toolbelt.

Rev. C, 09/18: 

replaced 
Global Viewer 
with Extron 
Control apps.

VOLUME

MUTE

DISPLA

Y

OFF

ON

PC

DOC

CAM

LAPTOP

1

LAPTOP

2

HDMI

VGA

DISPLA

Y

OFF

ON

PC

DOC

CAM

LAPTOP

1

LAPTOP

2

HDMI 1

HDMI 2

VOLUME

MUTE

Содержание MLC Plus 84 EU

Страница 1: ...Extron Control apps for remote control applications Global Configurator and other useful software applications are available at www extron com Installation Step 1 Get Ready Use the following check list to prepare for the installation Download and install the latest version of the following Toolbelt software for discovering the controller and other control products on the network for managing core ...

Страница 2: ...lus 84 Read any installation instructions and regulatory guidelines that come with the mounting devices raceway junction box surface mounting box before installing the raceway or box Select and prepare the site before cabling the controller This may include cutting a hole in the installation surface or installing a cabling raceway running the cables to that site installing the wall box and pulling...

Страница 3: ...all the MLC Plus 84 securely so it cannot easily be removed after installation hold and install the bracket so that the side labeled Front faces out toward you and the unlabeled side faces the wall or furniture To install the MLC Plus 84 so it can be removed easily hold and install the bracket so the unlabeled side faces outward toward you and the side labeled Front faces the wall or furniture Wal...

Страница 4: ...ob c Insert the tip of a small flat bladed screwdriver such as an Extron Tweeker through one of the slots at the sides of an EU or MK model faceplate as shown at right There are four slots per faceplate two on each side d Press the tab into the body of the MLC Plus 84 to release the faceplate from the circuit board e Repeat steps 1c and 1d with the remaining slots and tabs around the edges of the ...

Страница 5: ...he tabs are inserted into the slots and the ridge on each tab snaps into place in the faceplate NOTE It is important to make sure that ALL eight tabs are securely snapped into place 5 If reattaching the volume control faceplate place the knob back on its shaft and use the small Allen wrench to tighten the set screw to secure the knob VOLUME MUTE DISPLAY OFF ON PC DOC CAM LAPTOP 1 LAPTOP 2 HDMI VGA...

Страница 6: ...ith Wall Frames Rear Panel Features RESET LAN PoE POWER 12V 0 4A MAX Tx Rx G Tx Rx G 1 2 C G C V G S COM 1 COM 2 VOL IR G IN D IN RELAYS RESET LAN PoE POWER 12V 0 4A MAX Tx Rx G Tx Rx G 1 2 C G C V G S COM 1 COM 2 VOL IR G IN D IN RELAYS Power input connector COM RS 232 ports IR output port Relay ports Reset LED Reset button Digital input port Volume control port LAN PoE Ethernet connector and LED...

Страница 7: ...on the bottom of the rear enclosure Link LED Lights green to indicate a network connection Activity LED Blinks yellow to indicate data is being sent or received Default protocol MLC Plus 84 IP address 192 168 254 250 Gateway IP address 0 0 0 0 Subnet mask 255 255 255 0 DNS address 127 0 0 1 DHCP off Link speed and duplex level autodetected Data rates 10 100Base T Use this port to upload configurat...

Страница 8: ...rce Device Two Single IR Emitters Ground IR Output Ground IR Output Unidirectional IR or 3 16 5 mm max To Projector Panel Display or the Wired IR Remote of a Source Device IR Output Port Output options IR 30 kHz to 300 kHz with or without carrier signals Ground IR Signal Dual IR Emitter Control Unidirectional Digital Input 1 2 C G C V VOL G IN D IN RELAYS Digital Input Configure the port with or w...

Страница 9: ...close as possible to the amplifier to avoid picking up background noise via the cable NOTE When audio mute is active the MLC Plus 84 sets output voltage to 0 VDC even if the voltage range minimum and maximum voltage limits have been set to levels above zero such as 2 V to 8 V Step 5 Set up the MLC Plus 84 for Network Communication 1 Connect the PC that you will use for setup and the MLC Plus 84 to...

Страница 10: ...ch touchpanels to interact with Whom to notify how and under what circumstances a Configure ports on the controller Select device drivers and link them to each assigned serial IR or Ethernet port Select settings serial protocol relay behavior digital input volume control settings as needed b Set up monitors schedules macros and local variables c Set up the front panel buttons assign appropriate co...

Страница 11: ...all frame to the mounting bracket metal which you attached to the mounting surface during site preparation see Site Preparation on page 2 2 Holding the wall frame in place on the bracket press the cabled MLC Plus 84 into the frame until the two tabs on either side of the unit snap into the opening of the bracket holding the MLC Plus 84 in place MLC Plus 84 EU VOLUME MUTE DISPLAY OFF ON PC DOC CAM ...

Страница 12: ...he Reset LED blinks 6 times if the DHCP client is enabled The Reset LED blinks 3 times if the DHCP client is disabled NOTES DHCP toggle mode is supported on firmware version 3 00 0000 or higher By default DHCP is off and the unit uses a static IP address When you disable DHCP the unit uses the factory default IP address 192 168 254 250 Reset All IP Settings Press and hold the rear panel Reset butt...

Страница 13: ...ed for the previous generation IP Link non Pro controllers are not compatible Removing the MLC Plus EU or MK from the Mounting Surface Before you can replace buttons or faceplates on an MLC Plus 84 EU or MK if the unit is installed in a wall or furniture you must remove the unit from the metal mounting bracket and installation surface To help with this task Extron provides a removal tool shown at ...

Страница 14: ...p 4 Cable the MLC Plus 84 then apply power Cable all devices see step 4 Step 2 Prepare the installation site Step 1 Get ready Step 3 Change buttons or faceplates if desired Step 8 Mount the MLC Plus 84 Create monitors schedules timers macros and local variables Build and upload the configuration to the controller Step 6 If desired or required install a new security certificate via Toolbelt Within ...

Отзывы: