Operation and Setup, cont’d
ISM 824 Integration Scaling Multiswitcher • Operation and Setup
3-42
Editing the communication settings
To edit the communication settings, do the following:
N
The hardware address (the MAC address) is hard coded and cannot be changed.
In edit mode the MAC addresss menu is not displayed.
1
.
Press the Enter, Preset, View, and Esc buttons at the same time, and hold
down for 2 seconds. The LCD displays the Edit Comm Settings menu.
2
.
Press the Next button to enter the first sub level, Remote Port.
3
.
Rotate the left front panel encoder (
[
) to adjust the baud rate (9600, 19200,
38400, or 115200), and rotate the right encoder (
{
) to select the connection
type (RS-232/RS-422).
4
.
Press Next to go to the front panel’s Config Port menu.
5
.
Rotate the left front panel encoder (
[
) to adjust the baud rate (9600, 19200,
38400, or 115200), and rotate the right encoder (
{
) to select the connection
type (RS-232).
N
The hardware address (the MAC address) is hard coded and cannot be changed.
In edit mode the MAC addresss menu is not displayed.
6
.
Press Next to go to the DHCP Mode menu. From this menu, DHCP (Dynamic
Host Configuration Protocol) can be turned on or off. Default setting is off.
7
.
Rotate either front panel encoder to turn the DHCP mode on or off.
8
.
Press Next to go to the IP Address menu. In this menu the IP address of the
ISM 824 multiswitcher can be changed as desired. Valid IP addresses consist
of four 1-, 2-, or 3-digit numeric subfields separated by dots (periods). Each
field can be numbered from 000 through 255. Leading zeroes, up to 3 digits
total per field, are optional. Values of 256 and above are invalid. The default
IP address is 198.162.254.254.
9
.
Rotate the left front panel encoder (
[
) to select the field to be changed (the
field value flashes when selected), then rotate the right encoder (
{
) to change
the field values.
10
. Press Next to go to the Subnet Mask menu. In this menu the Subnet mask
of the ISM 824 multiswitcher can be changed as desired. The default is
255.255.000.000
11
. Rotate the left front panel encoder (
[
) to select the field to be changed, then
rotate the right encoder (
{
) to change the field values.
12
. Press Next to go to the Gateway Address menu. In this menu the Gateway
address of the ISM 824 multiswitcher can be changed as desired. The default
is 000.000.000.000
13
. Rotate the left front panel encoder (
[
) to select the field to be changed, then
rotate the right encoder (
{
) to change the field values.
14
. Press Next to return to the upper level Edit Comm Settings menu.
N
Press the Menu button to go directly to the next top level (System Reset) menu.
Содержание ISM 824
Страница 1: ...ISM 824 Integration Scaling Multiswitcher 68 1123 01 Rev A 02 08...
Страница 4: ...ISM 824 Integration Scaling Multiswitcher ii...
Страница 22: ...Introduction cont d ISM 824 Integration Scaling Multiswitcher Introduction 1 8...
Страница 130: ...ISM 824 Multiswitcher Software cont d ISM 824 Integration Scaling Multiswitcher ISM 824 Multiswitcher Software 5 28...
Страница 151: ...ISM 824 Integration Scaling Multiswitcher A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer...
Страница 158: ...Ethernet Connection cont d A 8 ISM 824 Integrated Scaling Multiswitcher Reference Information...
Страница 159: ...ISM 824 Integration Scaling Multiswitcher B Appendix B Reference Information Specifications Part Numbers and Accessories...