IN1806 and IN1808 Series Scaling Presentation Switchers • Operation
34
•
HDCP Authorized
— This feature determines if a digital input reports as an HDCP
authorized sink to a source. Select this item to enable or disable HDCP communication
by selecting whether the IN1806 or IN1808 Series input reports to the source as an
authorized HDCP sink. Press
Enter
to select this item, then press the
or
button
to toggle between
On
(default) and
Off
.
For source devices that require encryption, enable HDCP Authorized. If HDCP
Authorized is disabled for sources that require encryption (for example, a Blu-ray player),
the output is muted or a warning message is displayed. Some source devices may
encrypt their output even if the source material does not require HDCP encryption,
preventing content from being displayed on a non-HDCP compliant display. Disable
HDCP Authorized to allow the output of the scaler to remain unencrypted.
NOTE:
HDCP Authorized is permanently enabled on DisplayPort Input 1.
•
IN
n
: EDID
— Press the navigation buttons to select an EDID for the active input. Select
a discrete EDID from a list of factory-supplied EDID or select
Auto
to use the current
output resolution and refresh rate. The
on the next
page lists the available EDID selections, including their SIS command variable numbers
(see the
on page 63 for information on the SIS commands).
•
Capture EDID
— Select this item to capture the EDID of the sink device attached
to an output and save it to one of the 10 custom EDID slots. The IN1806 or IN1808
assigns the captured EDID to its selected input. To capture an EDID:
1.
Select
Capture
EDID
, then press
Enter
. A list of the 10 custom EDID slots is
displayed at the top of the OSD screen.
NOTES:
•
If no EDID has been captured yet, the names displayed for the slots are the
default:
1080p
@
60
Hz
.
•
If an EDID has been applied to a slot, last three letters of the EDID file
name (in parentheses) represent the name of the display manufacturer (for
example,
EXN
is an abbreviation of Extron).
Select Slot to Capture 1A EDID: 1920x1200 @ 59.95 Hz (DEL)
C1:
C1:3840x2160 @ 59.95 Hz (DEL)
C2:
C2:1920x1080 @ 60 Hz (EXN)
C3:
C3:1920x1080 @ 60 Hz (EXN)
C4:
C4:1920x1080 @ 60 Hz (EXN)
C5:
C5:1920x1080 @ 60 Hz (EXN)
C6:
C5:1920x1080 @ 60 Hz (EXN)
C7:
C5:1920x1080 @ 60 Hz (EXN)
C8:
C5:1920x1080 @ 60 Hz (EXN)
C9:
C5:1920x1080 @ 60 Hz (EXN)
C10:
C5:1920x1080 @ 60 Hz (EXN)
Figure 22.
Custom EDID Slots List Example
2.
Press the
or
button to move the highlighting to the slot to which you want to
save the current display EDID.
3.
Press the
or
button to display the output to which the select EDID will be
captured. In figure 22, output
1A
(HDMI) was selected and appears in the top panel.
22