NetLinx Module Interface Specification
for
Extron IN1508 Switcher/Scaler
Страница 1: ...Professional Control Solutions LLC 3804 Parchment Circle Richmond VA 23233 7034 804 364 3809 PCS_LLC comcast net NetLinx Module Interface Specification for Extron IN1508 Switcher Scaler...
Страница 2: ...on 3 Overview 3 Implementation 3 Port Mapping 4 Channels 5 Levels 5 Command Control 6 Command Feedback 7 Device Notes 7 Programming Notes 7 Adding Functions to Modules 8 Commands to the device 8 Respo...
Страница 3: ...erview The COMM module translates between the standard interface described below and the switcher serial protocol It parses the buffer for responses from the switcher sends strings to control the swit...
Страница 4: ...ation the device ID of the switcher to be controlled and the virtual device ID for communicating to the main program For an example of how to do this see below DEFINE_DEVICE dvSwt 5001 1 0 serial cont...
Страница 5: ...ion 24 PULSE Ramp Volume Up 1db 25 PULSE Ramp Volume Down 1db 26 PULSE Cycle Volume Mute 199 ON Set Volume Mute On used for feedback also OFF Set Volume Mute Off 251 ON Device is Online used for feedb...
Страница 6: ...gramming Notes section value 0 set all messages off 1 set all messages on DEBUG 1 PASSTHRU string Allows user the capability of sending commands directly to whatever unit is attached with minimal proc...
Страница 7: ...ll messages off 1 set all messages on DEBUG 1 SWITCH input Reports the input channel that is currently connected to the output channel This string is sent in response to the CL command being successfu...
Страница 8: ...e module will automatically generate the checksum In this case the following string should be sent from the UI code to implement white balance adjustment send_command vdvDevice PASSTHRU 03 10 05 14 Th...