Extron electronics GSS 100 Скачать руководство пользователя страница 1

Extron Electronics, USA

1230 South Lewis Street
Anaheim, CA 92805
USA
714.491.1500  
Fax 714.491.1517

Extron Electronics, Europe

Beeldschermweg 6C
3821 AH Amersfoort
The Netherlands
+31.33.453.4040  
Fax +31.33.453.4050

Extron Electronics, Asia

135 Joo Seng Road, #04-01
PM Industrial Building
Singapore 368363
+65.6383.4400  
Fax +65.6383.4664

Extron Electronics, Japan

Kyodo Building
16 Ichibancho
Chiyoda-ku, Tokyo 102-0082 Japan 
+81.3.3511.7655  
Fax +81.3.3511.7656

www.extron.com

© 2006  Extron Electronics.  All rights reserved.

User’s Manual

Graphic Still Store

68-974-01  

Rev. C

10 06

GSS 100

Содержание GSS 100

Страница 1: ...4040 Fax 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Kyodo Building 16 Ichibancho Chi...

Страница 2: ...n Wartung Alle Wartungsma nahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks ver...

Страница 3: ......

Страница 4: ...omputer or a computer network Step 5 If desired connect the GSS to a control system or control computer via the GSS s RS 232 port Step 6 Apply power to the GSS and the computer and or computer network...

Страница 5: ...e 3 12 Front panel absolute reset 3 13 Table of Contents Using the Menu System Use the Menu and Next buttons to navigate through the menu system Use the Adjust Select knob to make changes Switch Effec...

Страница 6: ...the GSS using the ARP command 5 3 Configuring the GSS using a direct PC connection 5 4 Accessing the HTML Pages 5 6 System Status Page 5 7 System Settings Page 5 8 IP Settings section 5 9 Unit Name fi...

Страница 7: ...nts Table of Contents cont d iv GSS 100 Graphic Still Store 1 Chapter One Introduction About the GSS 100 Graphic Still Store Features 68 974 01 Rev C 11 06 All trademarks mentioned in this manual are...

Страница 8: ...rage providing room for up to 17 uploaded bitmap images The number of images that the GSS can accommodate depends on the resolution of the images The table on the next page shows the number of bmp ima...

Страница 9: ...GSS 100 Graphic Still Store Introduction Introduction cont d GSS 100 Graphic Still Store 1 4 2 Chapter Two Installation Mounting the GSS Rear Panel Connections...

Страница 10: ...equipment nameplate ratings should be used when addressing this concern 5 Reliable earthing grounding Reliable earthing of rack mounted equipment should be maintained Particular attention should be gi...

Страница 11: ...e GSS and to control the GSS You can also use a PC to control the GSS with SIS commands Ethernet connection indicators The Link and Activity LEDs indicate the status of the Ethernet connection The Lin...

Страница 12: ...SIS Control for details RS 232 PIN RS 232 Function 1 None None None None None None 2 TX Transmit data 3 RX Receive data 4 5 Gnd Ground 6 7 8 9 Figure 2 5 RS 232 connector pinout Reset button f Reset...

Страница 13: ...GSS 100 Graphic Still Store Installation Installation cont d GSS 100 Graphic Still Store 2 8 3 Chapter Three Operation Front Panel Controls and Indicators Front Panel Operations...

Страница 14: ...s a desktop or laptop computers and the output monitor Use the LAN port to upload one or more still images to the GSS Select either the pass through input or one of the stored still images to output s...

Страница 15: ...nd then returns to the default display cycle once the image is loaded Muting the video output To toggle the video output mute on and off press and hold the Take button for approximately 3 seconds figu...

Страница 16: ...fect menu flowchart Effect submenu Rotate the Adjust Select knob while in the Effect submenu to cut immediate switch and dissolve the image dissolves from old to new Cut is the default selection Durat...

Страница 17: ...t Select knob while in the RGB Delay submenu to set the delay between 0 to 5 seconds in 0 1 second increments No delay 0 0 seconds is the default setting Slide Show menu Figure 3 9 is a flowchart that...

Страница 18: ...the automatic sync detection the slide show Off show auto switch off and slide show on Leaves the automatic sync detection off and manually initiates the slide show If the pass through input was bein...

Страница 19: ...using SIS commands or the HTML pages See chapter 4 SIS Control and chapter 5 HTML Control and IPL File Manager Exit menu Press and release the Next button while in the Exit menu to return the LCD to...

Страница 20: ...GSS 100 Graphic Still Store Operation Operation cont d GSS 100 Graphic Still Store 3 14 4 Chapter Four SIS Control Simple Instruction Set Control...

Страница 21: ...pts Indicate the error message displayed if the command is entered incorrectly or with invalid parameters See Error responses later in this chapter X Image file name Image name with file extension bmp...

Страница 22: ...econds If no data is received during the timeout period the Ethernet connection is closed Applicable to Ethernet connection only when connected via the RS 232 port only the global timeout commands app...

Страница 23: ...nd of the response character string A string is one or more characters Error responses When the GSS receives a valid SIS command it executes the command and sends a response to the host device If the...

Страница 24: ...ed image View pass through status X Pass through mode is X Slide show interval Set slide show interval 2 X Sli X Set the display time for each image to X seconds Read slide show interval 2 X The displ...

Страница 25: ...exactly as input Example 7 0 Pol0 Set the stored image s output sync polarity to H and V View output sync polarity 7 X The stored image s output sync polarity is X RGB delay pass through Set RGB dela...

Страница 26: ...part number Query firmwre vesion Q X1 Firmware version x xx Command ASCII Command host to switcher Response switcher to host Additional description Reset Erase all files E Zfff Zpf Reset flash memory...

Страница 27: ...n filesizen File n 1 space_remaining Bytes Left List selected files from current directory EX DF EX X DF Same response Same response X is the the first character of the file extension X X is the first...

Страница 28: ...ope 3 Daylight Savings Time on Brazil X3 IP address X3 Hardware MAC address X3 of open connections 0 255 X3 Password 12 digits alphanumeric N The following characters are invalid in passwords space an...

Страница 29: ...X3 Read IP address E CI X3 Read hardware address E CH X3 Read of open connections E CC X3 Set subnet mask EX3 CS Ips X3 Read subnet mask E CS X3 Set gateway IP address EX3 CG Ipg X3 Read gateway addre...

Страница 30: ...rol and IPL File Manager Configuring the Hardware Accessing the HTML Pages System Status Page System Settings Page Video Settings Page Passwords Page E mail Alerts Page Firmware Upgrade Page File Mana...

Страница 31: ...ult Web pages that are pre loaded in the GSS provide a way to reconfigure the GSS once it has an active network connection with IP access These Web pages are compatible with Netscape Navigator version...

Страница 32: ...end of a CAT 5 Ethernet crossover cable into the rear panel LAN port on the GSS See Cabling and RJ 45 connector wiring in chapter 2 Installation to make a cable 2 Plug the other end of the CAT 5 cabl...

Страница 33: ...d protected proceed to step 7 If the GSS is password protected the Enter Network Password page figure 5 2 appears Figure 5 2 Enter Network Password page N A User Name entry is not required 6 Click in...

Страница 34: ...Unit Name field contains the locally assigned name of the GSS This name field can be changed to any valid name up to 24 alphanumeric characters N The following characters are invalid in the unit name...

Страница 35: ...rom Greenwich Mean Time GMT N The Zone field identifies the standard time zone that was selected and displays the amount of time in hours and minutes that the local time varies from the GMT internatio...

Страница 36: ...Submit button Clicking the Cancel button abandons the changes N To clear an existing password so that no password is required enter a space in the Password and Re enter Password fields and click the S...

Страница 37: ...he firmware chip Access the Firmware Upgrade page figure 5 9 by clicking the Configuration tab and then the Firmware Upgrade link on the left side of the System Settings page System Settings Passwords...

Страница 38: ...File Management HTML page figure 5 11 Figure 5 11 File Management page N The files listed in figure 5 11 are shown for example only and may not be present on your GSS 100 To delete a file click the in...

Страница 39: ...and N If no new image has been selected the Current Image and Selected Image fields contain the same file name Figure 5 13 Image Settings page Uploading adding an image Upload an image to the GSS 100...

Страница 40: ...racters Cannot start with a number or a dash Cannot end with a dash N Other files such as image files are not constrained by these guidelines Installing the IPL File Manager and Uploading Images You c...

Страница 41: ...to step 4 N Select the Never ask again checkbox to skip the Select Startup Mode Window step from now on Figure 5 15 Select Startup Mode window 3 Type the GSS s IP address and if the GSS is password p...

Страница 42: ...RGB a In the Computer System left section of the IP Link File Manager window navigate the folder that contains the file s that you want to upload to the GSS b Select the file s that you want to uploa...

Страница 43: ...e the total number of JPEG images you can store divide 16 MB by the JPEG file size For example 16 MB 500 kB 0 5 MB 32 images Specifications Video input Number signal type 1 VGA UXGA RGBHV RGBS pass th...

Страница 44: ...closure type Metal Enclosure dimensions 1 75 H x 8 75 W x 9 5 D 1U high half rack wide 4 4 cm H x 22 2 cm W x 24 1 cm D Depth excludes connectors and knobs Product weight 4 5 lbs 2 1 kg Shipping weigh...

Страница 45: ...eet 7 5 meters 26 210 04 BNC 4 50 MHR 50 feet 15 0 meters 26 210 05 BNC 4 75 MHR 75 feet 23 0 meters 26 210 06 BNC 4 100 MHR 100 feet 30 0 meters 26 210 07 BNC 4 150 MHR 150 feet 45 0 meters 26 210 08...