DXP HD 4K Series • Operation
51
To perform a hardware reset of the switcher:
1.
Use a stylus or small Philips screwdriver to press and
hold
the rear panel
Reset
button
until the front panel
Video
and
Audio
buttons blink twice (for a system reset) or three
times (for an absolute reset).
RESET
RESET
RESET
RESET
RESET
RESET
Release, then immediately
press and release again.
Release, then immediately
press and release again.
IP Settings
Reset
(Mode 4)
6 seconds
Absolute Reset
(Mode 5)
9 seconds
Reset LED blinks twice.
Reset LED blinks
three times.
Front panel I/O buttons or LEDs blink twice.
Front panel I/O buttons blink three times.
I / O
AUDIO
VIDEO
I/O
VIDEO
AUDIO
DXP 88 Series
DXP 1616 Series
I / O
AUDIO
VIDEO
I/O
VIDEO
AUDIO
DXP 88 Series
DXP 1616 Series
Press and hold
the
Reset
button.
Press and hold
the
Reset
button.
Figure 77.
Soft Resets (Modes 4 and 5)
2.
Release the
Reset
button and then immediately press and release it again. Nothing
happens if the second momentary press does not occur within 1 second.
Selecting the Remote RS-232 Port Baud Rate
NOTES:
•
The serial port settings are protected when front panel lock mode 2 is selected. You
can view the settings in lock mode 2 but you cannot change them from the front
panel.
•
To enable changes to the baud rate settings, set the lock mode to
0
.
To view and configure the serial communications settings for the switcher from the front
panel:
1.
Simultaneously press and
hold
all
Control buttons (
Enter
,
Preset
,
View
[DXP 168
and 1616 only] and
Esc
) until all of the Control buttons or their LEDs light, as well as
input buttons 1 and 2 (approximately 2 seconds).