6.
Connect an RJ‑45 DTP or HDBT receiving device
on the previous
page) for either
DTP
or
HDBT
mode (see image to the right to properly wire the RJ-45 connector).
•
If the receiver is in the
Extron DTP2 series
, set the
DTP/HDBT toggle switch
(
) to
DTP
and
the
SEND POWER switch
(
) to the
UP (SEND POWER)
position.
On the receiver, set the
SEND POWER switch to the DOWN (OFF) position.
•
If the receiver is in the E
xtron Legacy DTP series
, set the
DTP/HDBT toggle switch
(
) to
DTP
and the
SEND POWER switch
) to the
DOWN (OFF)
position.
•
If the receiver is
HDBaseT enabled
, set the
DTP/HDBT toggle switch
(
) to
HDBT
, and the
SEND POWER switch
(
) to the
DOWN (OFF)
position.
ATTENTION:
•
Position these toggle switches (see
and
)
BEFORE
connecting the appropriate device to the TP
connector. Failure to comply can damage the endpoint.
•
Positionnez ces sélecteurs (voir
,
)
AVANT
de connecter l’appareil approprié au connecteur TP. Ne pas
respecter cette procédure pourrait endommager le point de connexion.
•
The DTP2 T 212 is configured to output power to
DTP2 models
only. If connected to a
Legacy DTP or HDBT device
, set
the SEND POWER toggle switch to the “DOWN” position (OFF). Failure to turn the power OFF will damage the connected
Legacy DTP device.
•
Le DTP2 T 212 est configuré pour fournir une alimentation aux modèles DTP2 uniquement. S’il est connecté à un autre
appareil, veuillez positionner l’interrupteur à bascule sur « DOWN » (OFF). Si l’interrupteur n’est pas positionné sur OFF,
vous risquez d’entraîner la défaillance de l’appareil Legacy DTP connecté.
NOTE:
When the output is configured for
DTP
mode
, remote power is available for Extron
DTP2
devices only. When the
output is configured for
HDBT
mode
, remote power is disabled and both the switching transmitter and receiver require their
own 12 VDC power supply.
DTP2 R 211
CONFIG
INPUT
LINK
OUTPUT
SEND
POWER
OFF
STATUS
SEND
POWER
OFF
SEND
POWER
OFF
DTP2 R 211
CONFIG
INPUT
LINK
OUTPUT
SEND
POWER
OFF
STATUS
SEND
POWER
OFF
SEND
POWER
OFF
SEND
POWER
OFF
DTP HDMI 330 Rx
OVER DTP
RS-232
IR
Tx Rx
Tx Rx
G
OFF
OFF
ON
ON
OFF
Rx G
Tx
RS-232
IR
Rx
Tx
OVER TP
POWER
12V
2.0A MAX
RS-232
CONTACT /
TALLY
1
C G T
C G
G
Rx
Tx
+V
T
2
1
AUDIO
2
A
B
REMOTE
INPUTS
OUTPUT
S
SIG LINK
OUT
DTP
HDBT
OFF
SEND
POWER
Rx G
Tx
RS-232
IR
Rx
Tx
OVER TP
POWER
12V
2.0A MAX
RS-232
CONTACT /
TALLY
1
C G T
C G
G
Rx
Tx
+V
T
2
1
AUDIO
2
A
B
REMOTE
INPUTS
OUTPUT
S
SIG LINK
OUT
DTP
HDBT
OFF
SEND
POWER
Rx G
Tx
RS-232
IR
Rx
Tx
OVER TP
POWER
12V
2.0A MAX
RS-232
CONTACT /
TALLY
1
C G T
C G
G
Rx
Tx
+V
T
2
1
AUDIO
2
A
B
REMOTE
INPUTS
OUTPUT
S
SIG LINK
OUT
DTP
HDBT
OFF
SEND
POWER
Local
Power Supply
CATx Cable
up to 330' (100 m)
Local
Power Supply
No Remote Power
Extron
DTP2 T 212
Transmitter
Extron
DTP HDMI 4K 330 Rx
Receiver
DTP Endpoint Connected to a DTP2 Endpoint
CATx Cable
up to 330' (100 m)
Direction of
Remote Power
Local
Power Supply
Extron
DTP2 T 212
Transmitter
Extron
DTP2 R 211
Receiver
CATx Cable
up to 330' (100 m)
Direction of
Remote Power
Extron
DTP2 T 212
Transmitter
Extron
DTP2 R 211
Receiver
DTP2 Endpoint Connected to a DTP2 Endpoint
Local
Power Supply
DTP2 R 211
CONFIG
INPUT
LINK
OUTPUT
SEND
POWER
OFF
STATUS
SEND
POWER
OFF
SEND
POWER
OFF
DTP2 R 211
CONFIG
INPUT
LINK
OUTPUT
SEND
POWER
OFF
STATUS
SEND
POWER
OFF
SEND
POWER
OFF
SEND
POWER
OFF
DTP HDMI 330 Rx
OVER DTP
RS-232
IR
Tx Rx
Tx Rx
G
OFF
OFF
ON
ON
OFF
Rx G
Tx
RS-232
IR
Rx
Tx
OVER TP
POWER
12V
2.0A MAX
RS-232
CONTACT /
TALLY
1
C G T
C G
G
Rx
Tx
+V
T
2
1
AUDIO
2
A
B
REMOTE
INPUTS
OUTPUT
S
SIG LINK
OUT
DTP
HDBT
OFF
SEND
POWER
Rx G
Tx
RS-232
IR
Rx
Tx
OVER TP
POWER
12V
2.0A MAX
RS-232
CONTACT /
TALLY
1
C G T
C G
G
Rx
Tx
+V
T
2
1
AUDIO
2
A
B
REMOTE
INPUTS
OUTPUT
S
SIG LINK
OUT
DTP
HDBT
OFF
SEND
POWER
Rx G
Tx
RS-232
IR
Rx
Tx
OVER TP
POWER
12V
2.0A MAX
RS-232
CONTACT /
TALLY
1
C G T
C G
G
Rx
Tx
+V
T
2
1
AUDIO
2
A
B
REMOTE
INPUTS
OUTPUT
S
SIG LINK
OUT
DTP
HDBT
OFF
SEND
POWER
Local
Power Supply
CATx Cable
up to 330' (100 m)
Local
Power Supply
No Remote Power
Extron
DTP2 T 212
Transmitter
Extron
DTP HDMI 4K 330 Rx
Receiver
DTP Endpoint Connected to a DTP2 Endpoint
CATx Cable
up to 330' (100 m)
Direction of
Remote Power
Local
Power Supply
Extron
DTP2 T 212
Transmitter
Extron
DTP2 R 211
Receiver
CATx Cable
up to 330' (100 m)
Direction of
Remote Power
Extron
DTP2 T 212
Transmitter
Extron
DTP2 R 211
Receiver
DTP2 Endpoint Connected to a DTP2 Endpoint
Local
Power Supply
Figure 3.
Send Power Toggle Switch Configuration
7.
Connect Over TP RS‑232 and IR control.
Connect a serial RS-232 signal, a modulated
IR signal, or both into this 3.5
mm, 5-pole captive screw port (
) for IR and bidirectional
RS-232 communication (see wiring diagram on the right).
3
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568B
TP Wires
12345678
Pins:
Rx Tx
Tx Rx
Gnd
Gnd
IR Device
RS-232 Device
OVER TP RS-232/IR
RS-232
O
VE
R
TP
IR
Tx
Rx
Tx
Rx
G
Tx/Rx
Pins
DTP2 T 212 • Setup Guide (Continued)
2