Extron DTP HD DA 4K Series • SIS Configuration and Control
13
X5*
=
Baud rate
Default
= 9600
Port 1 is fixed at 9600
X5(
=
Parity
Odd, Even, None (default), Mark, Space (only the
first letter is required)
X6)
=
Data bits
7-8
(
8
=
default
)
X6!
=
Stop bits
1, 2
(
1
=
default
)
X6$
=
Port timeout intervals
1-65000
(
1
= 10 seconds; default = 30 - 300 seconds = 5
minutes, in 10-second increments)
X6%
=
Start point for UART ports
1999
=
default
X6^
=
Video mute
0
= Video mute disabled
1
= Video mute
2
= Video and sync mute
X6&
=
View HDCP Notification
0
= Green screen (
default
);
1
= Black screen
Error Responses
•
E01
— Invalid input channel number
•
E10
— Invalid command
•
E13
— Invalid value
•
E24
— Privilege violation
•
E28
— Bad filename/File not found
EDID
User Assigned Mode
In user assigned mode, the user can select from 55 factory loaded EDID files, each
categorized by rate type (PC or HDTV), video format (DVI or HDMI), audio type (2-Ch or
Multi-Ch), and native resolution. The unit retains this setting after a power cycle.
Additionally, two user-loaded slots are available to save the EDID of any connected display.
EDID saved to these slots are retained after a power cycle. Upon a factory reset, these EDID
revert to the factory default (720p @ 60 Hz, 2-Ch audio).
A table showing the factory loaded EDID options is shown on the following page. The EDID
memory location is labelled
X$
for consistency with the value in the SIS commands.