DMP 64 Plus • SIS Configuration and Control
44
Command and Response Table for SIS Commands
Command
ASCII command
(host to device)
Response
(device to host)
Additional description
Information Requests
General information
I
V00X00
•
A06x04
•
E32x16
]
Response varies depending on
model.
Model name
1I
DMP 64 Plus
]
Response varies depending on
model.
Model description
2I
Digital audio matrix
processor
]
Response varies depending on
model.
System memory usage
3I
<number> Bytes Used out of
<number> KBytes
]
User memory usage
4I
<number> Bytes Used out of
<number> KBytes
]
Query firmware version
Q
{version x.xx}
]
Query firmware version with
build
*Q
{version x.xx.xxxx)
]
Query firmware version
(advanced)
X2&
Q
{specific version info}
]
Query part number
N
zz-zzzz-zz
]
KEY:
X2&
= Firmware Query:
0
= Detailed version information (includes all
2Q
,
3Q
, and
4Q
)
1
= Firmware version
2
= Final stage bootloader
3
= Factory base code version
4
= Updated firmware version
Ethernet Data Port
Set current connected port
timeout
E
0*
X2#
TC
}
Pti0*
X2#
]
View current connected
port timeout
E
0TC
}
X2#
]
Set global IP port timeout
E
1*
X2#
TC
}
Pti1*
X2#
]
View global IP port timeout
E
1TC
}
X2#
]
KEY:
X2#
= IP Timeout:
The number of seconds before timeout on IP connections (min =
1
, max =
65000
, and default =
30
[300 seconds]).
If no data is received during the timeout period, the Ethernet connection will be closed. Each step = 10 seconds.
Serial Data Port
Configure parameters
EX!
*
X1!
,
X1@
,
X1#
,
X2*
CP
}
Cpn
X!
•Ccp
X1!
,
X1@
,
X1#
,
X2$
]
View parameters
EX!
CP
}
X1!
,
X1@
,
X1#
,
X2$
]
View mode
EX!
CY
}
X1#
]
Configure flow control
EX!
*
X1%
,
X1^
CF
}
Cpn
X!
•Cfl
X1%
,
X1^
]
View flow control
EX!
CF
}
X1%
,
X1^
]
KEY:
X!
= Port Number:
01
(always
01
for DMP 64 Plus)
X1!
= Baud Rate:
300, 600,1200, 1800, 2400, 3600, 4800, 7200, 9600
,
14400, 19200, 28800,
38400
(default)
, 57600, 115200
X1@
= Parity:
O
dd,
E
ven,
N
one (default),
M
ark,
S
pace. Only use the first letter.
X1#
= Data Bits:
7
,
8
(default)
X1$
= Port Type:
0
= RS-232 (default)
X1%
= Flow Control:
H
ardware,
S
oftware,
N
one (default). Only use the first letter.
X1^
= Data Pacing:
Specified in milliseconds between bytes. 0000-1000ms (default is 0 ms). For host port or ports, this value is ignored
and always returns a 0.
X2$
= Stop Bits:
1
(default) or
2
.
Set global IP port timeout