Revision Date:
10/16/2020
Page 14 of 28
DMP Plus Series C V / C V AT – Patton POTS
3.0
Configuring DMP Plus Series C V (AT) VoIP Lines
VoIP configuration of the DMP Plus Series is handled exclusively through a web interface,
served from the device itself. The VoIP landing page is accessed through an address of the
format -
http://192.168.254.254/www/voip.html
- where 192.168.254.254 in this example is the default IP address on LAN 1 of the DMP Plus
Series device.
Line 1 will be configured as a SIP to POTS connection
3.1
Network Interface Configuration
Need to make sure that the LAN 1 and LAN 2 IP subnets (IP address / Subnet) do not overlap.
The default subnet mask on LAN 1 of 255.255.0.0 needs to be changed to 255.255.255.0
The LAN 1 IP interface will be used for Setup and control. These settings can be changed per
your application.
1.
Click on the
Network
tab followed by
Interface
tab
2.
Under the LAN 1 Network interface:
a.
IP address Mode:
Static
b.
IP address:
192.168.254.254
c.
Subnet Mask:
255.255.255.0
d.
Gateway:
0.0.0.0
3.
Click
Apply
after making any changes
a.
The Network interface will restart the VoIP services on the device.
4.
After the network interface has restarted