4-23
CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide
Command/response table for IP-Specific SIS commands (continued)
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
IP setup commands (continued)
N
You must have first set an e-mail recipient for the e-mail account number (
X4!
), using the Set e-mail recipient (CR)
command, before you can assign events to monitor with the Set e-mail events for recipient (EM) command (see previous
page).
Set e-mail events for
recipient
EX4!
,
X4#
,
X4$
,
X4$
, ... ,
X4$
EM
}
Ipe
X4$
,
X4$
,
X4$
, ... ,
X4$]
Example:
E
73,3,110000 ... 0111EM
}
See below.
Response description:
Notify what?, inputs 1
–
64 (inputs above the matrix size are always 0) power supplies fan
Response example (for
CrossPoint 450 Plus 6464
):
Response:
Notify failed and fixed
3, 1 1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
01
Input:
02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18
52 53
51
54 55 56 57 58 59 60 61 62 63 64
Fans
Power Supplies
E-mail input 8 status
E-mail power supply and fan status
Ignore input 16
0 0 0 0 0 0 0 0 1 1 1
Read e-mail events for
recipients
EX4!
EM
}
X4$
,
X4$
,
X4$
, ... ,
X4$]
Set DHCP on or off
EX4^
DH
}
Idh
X4^]
X4^
: 0 = off, 1 = on
Read DHCP on/off status
E
DH
}
X4^]
Set serial port parameters
EX4&
*
X4*
,
X4(
,
X5)
,
X5!
CP
}
Cpn
X4&
•Ccp
X4*
,
X4(
,
X5)
,
X5!]
Read serial port parameters
EX4&
CP
}
X4*
,
X4(
,
X5)
,
X5!]
Set serial port mode
EX4&
*
X5@
CY
}
Cpn
X4&
•Cty
X5@]
X5@
: 0 = RS-232, 1 = RS-422
N
The front panel Configuration port
(
X4&
= 2) is limited to the RS-232 protocol only.
Read serial port mode
EX4&
CY
}
X5@]
Set verbose mode
EX5#
CV
}
Vrb
X5#]
Read verbose mode
E
CV
}
X5#]
Read connection’s security
level
E
CK
X5$]
Configure current port
timeout
E
0*
X5%
TC
}
Pti0*
X5%]
View current port timeout
E
0TC
}
X5%]
Configure global IP port
timeout
E
1*
X5%
TC
}
Pti1*
X5%]
View global IP port timeout
E
1TC
}
X5%]
Special Characters
The HTML language reserves certain characters for specific functions. The switcher
does not accept these characters as part of preset names, the switcher’s name,
passwords, or locally created file names.
The switcher rejects the following characters:
{space (spaces
are
ok for names)} + ~ , @ = ‘ [ ] { } < > ’ “ semicolon (;)
colon (:) | \ and ?.
Содержание CrossPoint 450 Plus 3248 HV
Страница 1: ...CrossPoint 450 Plus Series MAV Plus series Large Scale Matrix Switchers 68 521 03 Rev B 11 09 ...
Страница 4: ......
Страница 10: ...Table of Contents cont d CrossPoint 450 Plus and MAV Plus Switchers Table of Contents vi ...
Страница 32: ...Installation cont d CrossPoint 450 Plus and MAV Plus Switchers Installation 2 14 ...
Страница 86: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 54 ...
Страница 88: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 56 ...
Страница 112: ...Programmer s Guide cont d CrossPoint 450 Plus and MAV Plus Switchers Programmer s Guide 4 24 ...
Страница 161: ...CrossPoint 450 Plus and MAV Plus Switchers A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer ...
Страница 183: ...B 15 CrossPoint 450 Plus and MAV Plus Switchers Reference Information Button label blanks ...
Страница 184: ...Reference Information cont d CrossPoint 450 Plus and MAV Plus Switchers Reference Information B 16 ...