background image

1

AC 102 and AC+USB 311 No AC Power Modules  
for the Cable Cubby Enclosures • Installation Guide

The AC 102 and AC+USB 311 No AC Power Modules provide slots for installing one or two compatible AC outlets (purchased 
separately) for powering and charging laptops and other portable devices. The No AC Power Modules are compatible with the 
following outlets: 

• 

Legrand Israel 572124

 — White  

 

Legrand India 573471

 — White 

• 

Legrand

 

Israel

 

572624

 — Magnesium  

 

Legrand

 

India

 

573671

 — Magnesium

See the CAUTION and ATTENTION notifications before installing the outlets and mounting the power module. Follow the steps 
below to properly install and secure the module.

Installing the AC Outlets in the Power Modules

CAUTION:
ATTENTION :

 

• 

All electrical installation should be performed by qualified personnel in accordance with local and national building, fire 
and safety, and electrical codes.

• 

Toute installation électrique devrait être effectuée par un personnel qualifié, conformément aux codes du bâtiment, aux 
codes incendie et sécurité, et aux codes électriques locaux et nationaux.

• 

To ensure proper electrical grounding, use the provided #6-32 grounding screws and star washers.

• 

Afin d’assurer une mise à la terre correcte, utilisez les fixations de mise à la terre #6-32 et les rondelles en étoile fournies.

ATTENTION:

 Follow all national and local building and electrical codes that apply to the installation site. Extron is not liable nor 

responsible for damage or injury as a result of installing this product. It is the responsibility of the qualified installer to ensure 
applicable safety, compliance, and technical steps have been performed in accordance to regulatory, building and electrical 
standards.

The AC 102 No AC power module has two slots at the top, through which you can  
access two sets of cables in order to wire them to the outlets. The AC+USB 311 has one slot  
and one set of cables for wiring. Each set consists of the following three colored cables:

  

Brown

 — Live        

  

Blue

 — Neutral         

  

Green

 — Ground

To wire the outlets to the module:

1. 

Each set of cables (one brown, one blue, and one green) is zip-tied together and placed 
inside the module (see 

1

 in the illustration at right). Pull one zip-tied set of cables out 

through each slot, so that the loose ends of the cables are accessible (

2

). 

2. 

Remove the partially-severed insulation from the ends of the cables to expose the bare  
wires (

3

).

3. 

Place the module on a flat surface with the slots facing up and the word 

Top

 (between two 

arrows pointing up) facing toward you, as shown at right.

4. 

Attach the wires to each outlet as follows:

a. 

Loosen the three screws on the back of the outlet (see 

1

 

in the illustration below, right).

b. 

Insert each wire into the appropriate captive screw 
connector (use either of the two holes):

• 

Live (brown) cable

 — 

L

 connector (

2

• 

Ground (green) cable

 — Ground connector (

3

), 

labeled with 

_

_

.

• 

Neutral

 

(blue) cable 

— 

N

 connector (

4

)

c. 

After inserting each wire, tighten the screw above it to 
hold it in place (

1

). Pull gently on each wire to ensure 

it is securely attached.

240V~ 50-60Hz 10A MAX TOT

AL

TOP

1

1

3

3

2

2

L

N

Blue = Neutral

Green = Ground

Brown = Live

1

1

1

3

3

3

2

2

2

4

4

4

Figure 2.      

Connecting Wires to AC Outlet

IMPOR

TANT

:

Go to ww

w.extr

on.com for th

e

complete user guide and installation

instructions befor

e connecting the

product to the power sou

rce.

Figure 1.      

AC 102 Module with Wires