background image

 

Maintenance Safety

Summit X460-G2 Series Switches Installation Note

4

permanently attached to the equipment rack so that it is always available when you need to handle 
ESD-sensitive components.

Install all cables in a manner that avoids strain. Use tie wraps or other strain relief devices. 

General Safety Precautions

Do not try to lift objects that you think are too heavy for you.

When you install equipment in a rack, load heavier devices in the lower half of the rack first to 
avoid making the rack top-heavy.

For Summit desktop equipment installations, do not place a monitor or other heavy objects on top of 
the equipment. The chassis cover is not designed to support weight.

Use only tools and equipment that are in perfect condition. Do not use equipment with 
visible damage.

Route cables in a manner that prevents possible damage to the cables and avoids causing accidents, 
such as tripping. 

Selecting AC Power Supply Cords

Extreme Networks does not include AC power input cords in the product box. To purchase a power 
cord for your product and for your specific country, contact your local Extreme Networks Channel 
Account Manager or Sales Manager, or purchase a cord from your local supplier. 

To locate a Sales Manager or Partner in your region visit: 

http://www.extremenetworks.com/how-to-buy/how-to-buy.aspx

Power cords that are used with AC-powered Summit X460-G2 series switches must meet the 
following requirements: 

The power cord must be agency-certified for the country of use.

The power cord must have an IEC320-C13 connector for connection to the switch or external power 
supply.

The power cord must have an appropriately rated and approved wall plug applicable to the country 
of installation.

For cords up to 6 feet (2 m) long, the wire size must be 18 AWG (.75 mm

2

) minimum; over 6 feet, the 

minimum wire size is 16 AWG (1.0 mm

2

).

Connecting Power

For the specific ratings and input power requirements of each switch model, see the data sheet for the 
Summit X460-G2 series switches at http://www.extremenetworks.com.

WARNING!

Be sure to satisfy the requirements listed in this section when you connect all Extreme Networks 

equipment to power. 

Содержание Summit X460-G2-24p-10GE4

Страница 1: ...e for the current rating of this product See Selecting AC Power Supply Cords on page 4 Required Tools The following items are provided with the Summit X460 G2 series switch Two rack mounting brackets...

Страница 2: ...rack Figure 2 Figure 2 Installing the Switch in the Rack 4 Insert and tighten rack mounting screws to secure the switch to the rack 5 Connect the power cable to the AC input power connector on the bac...

Страница 3: ...ricted access ensuring that only trained and qualified service personnel have access to the equipment Establish at least 3 inches clearance on all sides for effective ventilation Do not obstruct air i...

Страница 4: ...input cords in the product box To purchase a power cord for your product and for your specific country contact your local Extreme Networks Channel Account Manager or Sales Manager or purchase a cord...

Страница 5: ...NING Make sure that the source outlet is properly grounded according to the country s local electrical requirements before plugging the AC supply power cord into a power supply Cable Routing for LAN S...

Страница 6: ...e encapsulated and must be replaced only by qualified Extreme Service personnel Contact your Extreme Networks Service personnel for product replacement Do not attempt to replace the battery If these i...

Страница 7: ...w to avoid exposure to hazardous radiation Never look at the transmit LED laser through a magnifying device while the transmit LED is powered on Never look directly at a fiber port on the switch or at...

Страница 8: ...nt pas de contact pour mettre l appareil sous et hors tension D branchez tous les cordons d alimentation pour couper l alimentation de l appareil Assurez vous que ces connexions sont facilement access...

Страница 9: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a...

Страница 10: ...Conformity Statements for EMC Class A Summit X460 G2 Series Switches Installation Note 10...

Страница 11: ...four of which are shared with SFP ports four combo SFP ports and four dedicated SFP ports 100 10000BASE X and 100FX and four ports of 10G SFP two of these ports are configurable to be stacking ports O...

Страница 12: ...nd four ports of 1G SFP two of these ports are configurable to be stacking ports One front panel USB port One rear panel VIM slot One rear panel TM CLK clock slot Dual PSU power slots with front to ba...

Страница 13: ...be stacking ports One front panel USB port One rear panel VIM slot One rear panel TM CLK clock slot Dual PSU power slots with front to back or back to front airflow One slot for fan module with front...

Страница 14: ...48 and four ports of 10G SFP two of these ports are configurable to be stacking ports One front panel USB port One rear panel VIM slot One rear panel TM CLK clock slot Dual PSU power slots with front...

Страница 15: ...E4 switch Summit X460 G2 24x 10GE4 switch Summit X460 G2 48x 10GE4 switch Height 1 73 inches 4 4 cm Width 18 7 inches 47 5 cm Depth 10 0 inches 25 4 cm Weight with blanks no PS or fan Summit X460 G2 2...

Страница 16: ...t X460 G2 Series Switch Bundles Bundle Part No Configuration Name Qty Part No Power Supply Description Summit X460 G2 24t 16721 16721T X460 G2 24t 10GE4 FB AC X460 G2 24t 10GE4 FB AC TAA 1 3 10930A 10...

Страница 17: ...air flow Delta PSU Model EDPS 300AB CA Summit X460 fan module Front to Back air flow Fan Model AS04012UB565300 16724 16724T X460 G2 48t 10GE4 BF AC X460 G2 48t 10GE4 BF AC TAA 1 3 10943 10946 Summit...

Страница 18: ...n module Back to Front air flow Fan Model JDD0405612UB3A01 16766 16766T X460 G2 24p GE4 FB 1100 X460 G2 24p GE4 FB 1100 TAA 1 3 10941 10945 Summit 1100W AC PSU Front to Back air flow Samsung PSU Model...

Страница 19: ...t air flow Delta PSU Model EDPS 300AB CA Summit X460 fan module Back to Front air flow Fan Model JDD0405612UB3A01 16737 16737T X460 G2 24x 10GE4 FB DC X460 G2 24x 10GE4 FB DC TAA 1 3 10933 10945 Summi...

Страница 20: ...nt to Back Power Supply 300W DC Back to Front Power Supply Part 10933 300W DC PS FB front to back Part 10944 300W DC PS BF back to front Model PSSW301201A Model PSSW301202A 24VDC or 48VDC 5 25 A per P...

Страница 21: ...10GE4 1110W Power Supply Note All installed PS power supplies must have the same wattage and part number 715W Power Supply Note All installed PS power supplies must have the same wattage and part numb...

Страница 22: ...Summit X460 G2 Series Switches Summit X460 G2 Series Switches Installation Note 22...

Отзывы: