X440-G2 Series Switch Quick Reference

For complete installation instructions see the 

Extreme Networks 

Summit Family Hardware Installation Guide 

at: 

www.extremenetworks.com/documentation

Hardware Components

The following figures display the front and rear panel ports, LEDs, 
and hardware components on a typical X440-G2 switch. See the 

Extreme Networks Summit Family Hardware Installation Guide

 for 

component details.

Figure 1

 X440-G2 Sample Front Panel

Figure 2

 X440-G2 Sample Rear Panel (AC power)

Figure 3

 X440-G2 Sample Rear Panel (DC power)

Installation Site Requirements

The installation site must be within reach of the network cabling 
and meet the requirements listed below:
• Appropriate grounded power receptacles must be located 

within six feet of the site.

• A temperature of between 0°C (32°F) to 60°C (140°F) with 

fluctuations of less than 10°C (18°F) per hour must be 
maintained for the following X440-G2 switches: 
– X440-G2-12t8fx-GE4
– X440-G2-24fx-GE4
– X440-G2-24t-GE4
For all other X440-G2 series switches, a temperature of 
between 0°C (32°F) and 50°C (122°F) must be maintained at 
the installation site with fluctuations of less than 10°C (18°F) per 
hour.

Handling the Switch

To prevent electrostatic damage, attach an electrostatic discharge 
(ESD) wrist strap to your wrist before handling the switch.
Unpack the switch as follows:
1

Remove the packing material protecting the switch.

2 Remove the tape seal on the non-conductive bag to remove the 

switch.

Electrical Hazard: 

Only qualified personnel should perform 

installation procedures.

Risques d’électrocution: 

Seul un personnel qualifié doit effectuerles 

procédures d'installation.

Note: 

Switch models X440-G2-12t8fx-GE4, X440-G2-24fx-GE4, and X440-G2-

24t-GE4 do not support stacking. The front panel stack LED on these models 
does not function. 

1

USB port

4

10/100/1000BASE-T copper ports

2

Stack LED

5

1000BASE-X SFP ports

3

Console/Management ports

6

Shared ports

1

10GBASE-X SFP+ ports

4

Redundant power input

2

10GBASE-T copper ports

5

Grounding lug

3

AC power input socket

6

Shared ports

1

10GBASE-X SFP+ ports

4

DC power connector panel

2

10GBASE-T copper ports

5

Grounding lug

3

Redundant power input

6

Shared ports

Caution: 

To ensure proper ventilation and prevent overheating, leave a 

minimum clearance space of 5.1 cm (2.0 in.) on both sides of the device.

Warning: 

A readily accessible disconnect device shall be incorporated in the 

building installation wiring.

Caution: 

The switch can be damaged by electrostatic discharge.

3 Perform a visual inspection of the switch for any signs of 

physical damage. Contact Extreme Networks if there are any 
signs of damage. See 

“Getting Help”

 for more information on 

contacting Extreme Networks. 

Installing the Summit X440-G2 Series Switch

You can install a Summit X440-G2 Series switch in a rack. There are 
four possible rack mounting configurations, depending upon 
whether:
• The switch I/O ports or the power supply side of the device face 

front

• The device is mounted flush with the rack posts or mid-mounted

Secure the X440-G2 Series switches to the Rack

To secure the Summit X440-G2 Series switches to the rack:
1

Attach the mounting brackets to the sides of the switch using 
six screws for each bracket. 

2 Align the rack mount ear holes with the front rack post holes.
3 Secure the Summit X440-G2 Series switches to each rack post 

with two screws or fasteners appropriate to the rack.

Install Optical Transceivers

This installation procedure applies to all optical transceivers. To 
install a transceiver in a Summit X440-G2 Series switch:
1

Attach the anti-static wrist strap to your wrist and connect the 
metal end to an appropriate ground point on the rack.

2 Remove the optical transceiver from the packaging.
3 If there is a protective dust cover on the connector, remove it at 

this time.

4 Hold the optical transceiver so that the connector will seat 

properly.

5 Carefully align the optical transceiver with the port slot.
6 Push the optical transceiver into the port slot until the 

transceiver clicks and locks into place.

Connect Power to the Switch

You can connect to a single, primary source of power, or to two 
sources of power for redundancy. 

To power-up your X440-G2 Series switch, do the following:
1

For AC powered units, connect the AC power cord to the AC 
power input socket on the switch and an AC power outlet.

2 For DC powered switches, first verify the DC circuit is de-

energized and then do the following:

a Identify the grounding lug on the back of the switch. The 

grounding lug is the middle screw of the power connector 
panel, identified by the international symbol for earth ground.

b Connect the spade terminal end of the ground wire to the 

grounding lug of the power connector panel on the rear of 
the switch and the other end to a reliable earth ground. 

c Connect the DC power input cables to the DC input terminal 

block on the rear of the switch.

d Energize the circuit. 

3 If applicable, attach the cable from your redundant power 

supply (RPS) into the X440-G2 Series switch’s redundant power 
supply receptacle. 

4 Once power is connected, verify that the PSU LED and RPS LED 

(if applicable) turns green. If the PSU and RPS LEDs do not turn 
green, refer to the 

Extreme Networks Summit Family Hardware 

Installation Guide

 for troubleshooting information.

Caution: 

Before rack-mounting the device, ensure that the rack can support it 

without compromising stability. Otherwise, personal injury and/or equipment 
damage may result.

Note: 

The rack mounting brackets provide two holes for securing the Summit 

X440-G2 Series switches to the rack. Use two screws or fasteners appropriate 
to your rack on each side when securing the X440-G2 Series switch to the rack.

Warning: 

LASER RADIATION

Fiber-optic ports use Class 1 or Class 1M lasers. 
DO NOT EXPOSE USERS OF TELESCOPIC OPTICS
Do not use optical instruments to view the laser output. The use of optical 
instruments to view laser output increases eye hazard. Use only UL/CSA 
recognized pluggable modules.

Avertissements: 

RAYONNEMENT LASER 

Ports de fibres optiques utilisent des lasers de classe 1 ou de 
classe 1M . 
NE PAS exposer les utilisateurs de télescopique OPTIQUE.
Ne pas utiliser d'instruments optiques pour voir la sortie du laser. 
L'utilisation de instruments optiques pour afficher la sortie laser 
augmente les risques oculaires. Utilisez uniquement UL / CSA 
reconnue modules enfichables.

Warning: 

Extreme Networks power supplies do not have switches for turning 

the unit on and off. Disconnect all power cords to remove power from the 
device. Make sure that these connections are easily accessible.

Warning: 

A dedicated Listed circuit breaker rated at 15A is to be used for each 

power supply connection.

Warning: 

Always make sure that the DC circuit is de-energized before 

connecting or disconnecting DC power cables.

Note: 

Installing the system as described in this guide meets the protective earth 

grounding requirements of the National Electrical Code (NEC) UL 60950 and 
IEC 60950 standards. However, in some cases, it may be necessary to use an 
alternative grounding method. In these cases, a 14 AWG wire can be connected 
between the ground lug on the chassis and a nearby building ground point. 

Selection of Power Cords

Extreme Networks does not include any power input cords. To 
purchase the correct power cord for your specific country, refer to 

www.extremenetworks.com/product/powercords/

 for power cord 

details to purchase a cord from Extreme Networks or your local 
supplier.

Initial Network Connection and Configuration

Once you have connected power to the switch and verified LED 
activity, complete the setup process as follows:
1

Connect a management station to the console port using either 
an Ethernet to serial adapter or DB-9 serial cable 

2 Verify that the system LEDs are on (solid green or blinking 

green).

3 Using PuTTY, TeraTerm, or other terminal emulator, connect to 

the switch using the serial port connection. Be sure that your 
serial connection is set properly:
– 9600  baud
– 8 data bits
– 1  stop  bit

4 Using the console session, perform the following:

a At the password prompt, press ENTER (RETURN) twice. 
b Enter user: 

admin

c For the initial password, simply press ENTER.
d Follow the screen prompts for initial configuration.
e Enter  the 

show version 

command. Record the switch serial 

number. The following is example output with the serial 
number in bold: 

Transit.3 # show version
Switch : 800444-00-05 

1208G-00882

 Rev 5.0 BootROM

5 Go to Extreme Networks e-support at

 https://

esupport.extremenetworks.com

6 After logging in, go to the product registration page: 

http://

extrwebapps.extremenetworks.com/Webapps/Public/
ProductReg/.

7 Enter the serial number of the switch.
8 Download the software to your pc from the software download 

page at the esupport website: 

https://

esupport.extremenetworks.com/eservice_enu/
start.swe?SWECmd=Login&SWEPL=1&SWETS=

9 Connect back to the switch via the console port and connect a 

Ethernet cable to the management port on the switch to your 
PC.

10 You might need to reset the IP address on your PC to some 

address (for example, 

10.10.10.10 255.255.255.0)

 to avoid 

IP conflict. 

11 At the switch, set the IP address of the switch (for example, 

enter: 

con mgmt ipa 10.10.10.9/24

). 

12 Enter 

save config

 to save your configuration.

13 Start a TFTP session using a program such as TFTPD64. Point 

the TFTP server to your PC IP address and EXOS image file 
saved on your PC. 

14 At the switch, download the new software to the switch 

(example:

 download image 10.10.10.10 summitX-

15.4.1.3-patch1-9.xos

).

15 Install the software after it loads by typing 

Y

 when prompted if 

you want to install the load.

16 When the download and install finishes, instruct the switch to 

reboot when prompted by entering: 

reboot

Optional CLI Commands

Once logged into the switch you can create new VLANs by issuing 
the following two commands:

create vlan <vlan name>

configure vlan <vlan name> tag XXXX   

(replace XXXX 

with the VLAN tag number - options are 1-4096)

These two commands will create a VLAN, give it a logical name, 
and assign a tag number. 
To configure a Default Gateway in the Extreme Networks CLI, 
enter: 

configure iproute add default <IP Address>

 

Port Configuration CLI Commands

For additional port configuration CLI commands, refer to the 

Extreme  XOS Command Reference Guide

 at: 

www.extremenetworks.com/documentation.

Specifications

Temperature and Humidity

Operating Temperature:

X440-G2-12t8fx-GE4, X440-G2-24fx-GE4, 
and X440-G2-24t-GE4: 0°C (32°F) to 60°C (140°F)
All other X440-G2 switches: 0°C (32°F) to 50°C (122°F)

Storage Temperature: 

-40°C to 70°C (-40°F to 158°F)

Operating Relative Humidity: 

10% to 95% (non-condensing)

Power Specifications

Switch Dimensions 

Interfaces

Each Summit X440-G2 Series switch has a USB, management, and 
console port. The following table lists the specific interfaces for 
each switch.

X440-G2-24t-10GE4
(Part # 16532)

100-240Vac, 0.45 A max., 50-60Hz

X440-G2-24p-10GE4
(Part # 16533)

100-240Vac, 4.9 A max., 50/60Hz

X440-G2-48t-10GE4
(Part # 16534)

100-240Vac, 0.7 A max., 50-60Hz

X440-G2-48p-10GE4
(Part # 16535)

100-240Vac, 9.2 A max., 50/60Hz

X440-G2-12t-10GE4
(Part # 16530)

100-240Vac, 0.35 A max., 50-60Hz

X440-G2-12p-10GE4
(Part # 16531)

100-240Vac, 2.6 A max., 50-60Hz

X440-G2-24t-10GE4-DC
(Part # 16536)

-48V DC, 1.0 A

X440-G2-48t-10GE4-DC
(Part # 16537)

-48V DC, 1.45 A

X440-G2-24x-10GE4
(Part # 16538)

100-240Vac, 0.8 A max., 50-60Hz

X440-G2-24fx-GE4
(Part # 16539)

100-240Vac, 0.65 A max., 50-60Hz

X440-G2-12t8fx-GE4
(Part # 16540)

100-240Vac, 0.5 A max., 50-60Hz

X440-G2-24t-GE4
(Part # 16541)

100-240Vac, 0.45 A max., 50-60Hz

X440-G2-24t-10GE4

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L 
Unpackaged Weight: 3.66 kg (8.07 lb)

X440-G2-24p-10GE4

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L 
Unpackaged Weight: 4.28 Kg (9.44 lb)

X440-G2-48t-10GE4

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L 
Unpackaged Weight: 5.03 Kg (11.09 lb)

X440-G2-48p-10GE4

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L 
Unpackaged Weight: 6.54 Kg (14.42 lb)

X440-G2-12t-10GE4

4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 2.62 Kg (5.78 lb)

X440-G2-12p-10GE4

4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 3.03 Kg (6.68 lb)

X440-G2-24t-10GE4-DC

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L 
Unpackaged Weight: 3.66 kg (8.07 lb)

X440-G2-48t-10GE4-DC

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 38.1 cm (15.01 in) L 
Unpackaged Weight: 5.02 Kg (11.07 lb)

X440-G2-24x-10GE4

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.64 Kg (8.02 lb)

X440-G2-24fx-GE4

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L
Unpackaged Weight: 3.76 Kg (8.29 lb)

X440-G2-12t8fx-GE4

4.4 cm (1.73 in) H x 30.5 cm (12.01 in) W x 26.1. cm (10.28 in) L
Unpackaged Weight: 2.88 Kg (6.35 lb)

X440-G2-24t-GE4

4.4 cm (1.73 in) H x 44.1 cm (17.38 in) W x 25.4 cm (10.01 in) L 
Unpackaged Weight: 3.62 kg (7.98 lb)

X440-G2-24t-10GE4
(Part # 16532)

Summit X440-G2 24 10/100/1000BASE-T, 4 SFP combo, 4 
10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, 
ExtremeXOS Edge license

X440-G2-24p-10GE4
(Part # 16533)

Summit X440-G2 24 10/100/1000BASE-T POE+, 4 SFP 
combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed AC PSU, 1 
RPS port, ExtremeXOS Edge license.

X440-G2-48t-10GE4
(Part # 16534)

Summit X440-G2 48 10/100/1000BASE-T, 4 SFP combo, 4 
10GBASE-X unpopulated SFP+, 2 10GE copper combo, 1 
Fixed AC PSU, 1 RPS port, ExtremeXOS Edge license

X440-G2-48p-10GE4
(Part # 16535)

Summit X440-G2 48 10/100/1000BASE-T POE+, 4 SFP 
combo, 4 10GBASE-X unpopulated SFP+, 2 10GE copper 
combo, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS Edge 
license

X440-G2-12t-10GE4
(Part # 16530)

Summit X440-G2 12 10/100/1000BASE-T, 4 10GBASE-X 
unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS 
Edge license

X440-G2-12p-10GE4
(Part # 16531)

Summit X440-G2 12 10/100/1000BASE-T POE+, 4 10GBASE-
X unpopulated SFP+, 1 Fixed AC PSU, 1 RPS port, 
ExtremeXOS Edge license

X440-G2-24t-10GE4-DC
(Part # 16536)

Summit X440-G2 24 10/100/1000BASE-T, 4 SFP combo, 4 
10GBASE-X unpopulated SFP+, 1 Fixed DC PSU, 1 RPS port, 
ExtremeXOS Edge license

X440-G2-48t-10GE4-DC
(Part # 16537)

Summit X440-G2 48 10/100/1000BASE-T,  4 SFP combo, 4 
10GBASE-X unpopulated SFP+, 2 10GE copper combo, 1 
Fixed DC PSU, 1 RPS port, ExtremeXOS Edge license.

X440-G2-24x-10GE4
(Part # 16538)

Summit X440-G2 24 unpopulated 1000BASE-X SFP,  4 10/
100/1000 combo, 4 10GBASE-X unpopulated SFP+, 1 Fixed 
AC PSU, 1 RPS port, ExtremeXOS Edge license

X440-G2-24fx-GE4
(Part # 16539)

Summit X440-G2 24 fixed 100BASE-FX LC connectors, 4 
1GBASE-X unpopulated SFP, 1 Fixed AC PSU, 1 RPS port, 
ExtremeXOS Edge license

X440-G2-12t8fx-GE4
(Part # 16540)

Summit X440-G2 12 10/100/1000BASE-T, 8 fixed 100BASE-
FX LC connectors, 4 1GBASE-X unpopulated SFP, 1 Fixed AC 
PSU, 1 RPS port, ExtremeXOS Edge license

X440-G2-24t-GE4
(Part # 16541)

Summit X440-G2 24 fixed 10/100/1000BASE-TX, 4 1GBASE-
X unpopulated SFP, 1 Fixed AC PSU, 1 RPS port, ExtremeXOS 
Edge license