TABLE 23
Fan module LED descriptions (continued)
LED purpose
Color
Status
Recommended action
Steady amber
Fan assembly is being initialized or
has a failure (full or partial).
Wait to see if the fan fully initializes.
If the LED remains amber, replace
the fan assembly.
Power
(SFM)
No light (LED is off)
Module is not powered on.
Ensure that the module is firmly
seated, that both ejectors are
pushed in fully, and that both
captive screws are tightened.
Green
Module is operational.
No action is required.
Status
(SFM)
No light (LED is off)
Module is either not operational or
does not have power.
Ensure that the module is firmly
seated, that both ejectors (arms on
the side of the module) are pushed
in fully, and that both captive screws
are tightened.
Amber
Module is faulty or initializing.
Check the module status by
entering the
show slots
command.
If LED remains amber, consult the
device supplier.
Green
Module is operational.
No action is required.
Interpreting switch fabric module LEDs
Refer to the following illustrations and table to interpret the LED patterns for the switch fabric module (SFM). The LED patterns may
temporarily change during device diagnostic tests.
Since the SFM is located behind the fan modules, LEDs are provided on the fan and management modules to check SFM status. For
the location of the SFM LEDs on the management module, refer to
Interpreting management module LEDs
on page 75. For the
location of the SFM LEDs on the fan module, refer to
There is also a label on the bottom center of the chassis that shows the SFM locations behind the fan modules.
If the fan module is removed, you can check the LEDs on the SFM, as shown in the following figure.
Interpreting switch fabric module LEDs
ExtremeRouting SLX 9850-4 Hardware Installation Guide
84
9035474-02 Rev AA
Содержание ExtremeRouting SLX 9850-4
Страница 10: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 10 9035474 02 Rev AA...
Страница 22: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 22 9035474 02 Rev AA...
Страница 30: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 30 9035474 02 Rev AA...
Страница 56: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 56 9035474 02 Rev AA...
Страница 94: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 94 9035474 02 Rev AA...
Страница 102: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 102 9035474 02 Rev AA...
Страница 114: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 114 9035474 02 Rev AA...
Страница 118: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 118 9035474 02 Rev AA...
Страница 136: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 136 9035474 02 Rev AA...
Страница 146: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 146 9035474 02 Rev AA...
Страница 150: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 150 9035474 02 Rev AA...