Страница 2: ...d for your model Tool service must be performed only by qualified repair personnel Repairs service or maintenance performed by unqualified personnel will void the warranty Only approved and authorised...

Страница 3: ...securely on a level surface Damage to the laser or serious injury could result if the laser falls WARNING DO NOT DISASSEMBLE THE LASER There are no user serviceable parts inside Disassembling the lase...

Страница 4: ...ery pack Alkaline battery pack Laser target Millimeter detector clamp Remote control Extreme A3 Mk II INCHES CM 1 1 2 3 4 5 6 7 2 3 SC AN RP M ITEM CHECKLIST Please ensure the following items are incl...

Страница 5: ...5 SC AN RP M Rotating laser port Protective lighthouse Control panel Battery compartment with rechargeable battery Rechargeable battery charging port LASER OVERVIEW FRONT...

Страница 6: ...6 LASER OVERVIEW BASE Carry handle Battery compartment with rechargeable battery 5 8 x 11 thread for horizontal operation on a tripod Padded feet for vertical operation on a flat surface...

Страница 7: ...7 LASER OVERVIEW BACK Rotating laser port Carry handle 5 8 x 11 thread for vertical operation on a tripod Padded feet for vertical operation on a flat surface...

Страница 8: ...d indicators Manual grade mode Scanning mode LASER OVERVIEW CONTROL PANEL Power indicator Speed control Grade adjustment manual mode counter clockwise rotation Grade adjustment manual mode clockwise r...

Страница 9: ...CONTROL OVERVIEW FRONT Power Tilt alarm Scanning mode Speed control LCD display screen Dial in grade mode Grade adjustment manual mode Clockwise rotation Grade adjustment manual mode Counter clockwise...

Страница 10: ...10 REMOTE CONTROL OVERVIEW LCD SCREEN Battery level Automatic grade mode Scan mode Manual grade mode Tilt alarm Rotation speed RPM X axis Y axis Self levelling...

Страница 11: ...11 REMOTE CONTROL OVERVIEW BACK Battery compartment...

Страница 12: ...ection mode LCD display screen LED indicator LED indicator LED indicator Laser sensor Metric or imperial selection press Screen backlight hold Bubble vial Bubble vial Speaker Power on off detector DET...

Страница 13: ...13 Measurement Unit DETECTOR OVERVIEW LCD SCREEN Brightness indicator Arrow indicator Arrow indicator Battery indicator Centre alignment Detection mode Plus and minus indicator Speaker indicator...

Страница 14: ...14 Battery compartment Staff clamp thread Staff clamp mounting points LCD display screen DETECTOR OVERVIEW BACK...

Страница 15: ...e can be present or where the chargers could be exposed to extreme temperatures If a charger becomes damaged stop using immediately and seek a replacement 12v in car charger The in car charger is for...

Страница 16: ...ht will flash when the battery is low The instrument should be re charged as soon as possible Battery pack capacity decreases at low temperatures a depleted pack may not function when cold Charging th...

Страница 17: ...t of the instrument below the control panel and slide the battery pack out If the screw is tight loosen with a screwdriver Insert the battery pack and retighten the battery pack screw For better weath...

Страница 18: ...ble Place the instrument onto the tripod with the lighthouse facing upwards and thread the yoke into the base until firm Do not over tighten as this may cause damage to the instrument or tripod Level...

Страница 19: ...le and ensure that the location is clear of traffic Select a place as close and practical to the work site as possible and ensure that the location is clear of traffic Extend the tripod legs to the re...

Страница 20: ...n mode press the scanning mode button several times to cycle through to full rotation or power the instrument off and on again OPERATION Powering on Press the power button once and the instrument will...

Страница 21: ...l need to be powered off and on again to reset its level position Manual grade mode To create a manual grade slope press the manual grade mode button The instrument will now be in the X axis manual gr...

Страница 22: ...o set a grade on this axis press the grade adjustment button to change straight to the Y axis To set a grade slope percentage on the Y axis press the or grade adjustment buttons on the remote control...

Страница 23: ...d by the LED on the front of the instrument To adjust the grade slope on the required axis press the or grade adjustment buttons on the remote control to tilt the laser beam up or down depending on di...

Страница 24: ...d control button to increase or decrease the speed of the laser head rotation The RPM will be displayed on the LCD screen To focus the laser beam between two points press the scanning mode button Pres...

Страница 25: ...ch the detector on by pressing the power button The LCD screen will turn on and the speaker will emit a small tone to indicate the instrument is operating The LCD screen will display the battery level...

Страница 26: ...indicate the position of the laser beam A digital measurement of either how far up or down the detector is from the laser line will also be displayed The detector will emit a constant beep once the l...

Страница 27: ...27 Detector position for horizontal beams Detector position for vertical beams USING YOUR DETECTOR continued...

Страница 28: ...ment to level Detect and note laser position on the wall or staff Without moving the tripod rotate the instrument 180 Detect and note laser position on the wall or staff Calculate the distance between...

Страница 29: ...Adjust the instrument or tripod so it is level Laser does not remain on for long periods of use Check the batteries Check the battery compartment for signs of damage Ensure they are clean and not ben...

Страница 30: ...ent is recommended every six months if ongoing accurate levelling is required or an impact has occurred The operator should check the accuracy of the instrument before precision levelling is attempted...

Страница 31: ...any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major fa...

Страница 32: ...32 To assist you with any queries or technical questions please contact customer support Australia 1300 658 338 New Zealand 0800 367 527 CUSTOMER SUPPORT...

Страница 33: ...ions Extreme A3 Mk II Product code 60050 Warranty 10 Years Accuracy 1 5mm at 30m Operating range 800m diameter Levelling range 9 5 Laser class 2 Red Battery life 20 hours IP rating 65 Weight kg 3 50 D...

Страница 34: ...www spoton com au...

Отзывы: