background image

GLENDA WIFI

pellet stoves UseR MANUAl

 

 

eNGlIsH/INGlese

 

Содержание GLENDA WIFI

Страница 1: ...GLENDA WIFI pellet stoves USER MANUAL ENGLISH INGLESE ...

Страница 2: ...ENGLISH 2 ...

Страница 3: ... of batteries 13 COMMISSIONING settings 13 Mains frequency 50 60Hz 14 Adjusting time day month and year 14 Adjusting language 14 Operation and logic 15 USER MENU 16 low 16 V1 Air 16 reset 16 SET CHRONO 17 Settings 18 set clock 18 Adjusting language 18 Display 18 STAND BY 18 Delta t OFF 19 Delta t On 19 COMFORT function 20 additional thermostat optional 20 Wifi remote control module TOTAL CONTROL a...

Страница 4: ...supply plug must be accessible after installation Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are essential for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled persons The hearth door must always be closed during normal functioning of the product When the appliance is functioning and ...

Страница 5: ... Installation in premises with fire hazards is forbidden Installation in residential premises except for sealed operation appliances is also forbidden in which there are liquid fuel operated appliances with continuous or intermittent operation which draw the combustion air in the room in which they are installed or in which there are type B gas appliances intended for room heating with or without ...

Страница 6: ...ollection cap must be provided at the base of the vertical section If the exhaust is not inserted in an existing flue a vertical section with a windproof end piece is required UNI 10683 The vertical duct can be inside or outside the building If the smoke duct is inserted in an existing flue it must be certified for solid fuel If the smoke duct is outside the building it must always be insulated Th...

Страница 7: ...ation environment which makes it ideal for passive houses as it does not take air from inside the homes combustion air To respect the air tight seal of the stove the combustion air connection pipe must be directly connected to the outside using specific sealed fittings and pipes FUMES EXHAUST SYSTEM If the generator has a fume temperature below 160 C ambient temperature due to high efficiency see ...

Страница 8: ...gers contact the qualified technician before rearming to verify the cause External thermostats input Input for external thermostats Serial inputs Input for WIFI module See instruction detail attached to the product Glenda Wifi details Display Pellet tank Room air outlet Lateral fumes outlet Ait inlet rear combustion Rear fumes outlet Upper fumes outlet Power supply External thermostats input Seria...

Страница 9: ...f the stove Both the pellet tank door and lid must always remain closed during stove operation Failure to comply with one of the above observations during operation will display the following CLOSE TANK DOOR This indicates that you have 30 to close the pellet door and lid Otherwise during ignition the stove will go in alarm ALL DEPR while during normal operation it will go in REIGNITION STAND BY t...

Страница 10: ...lets is 5 kWh kg Pellet density is 650kg m3 and the water content is equal to 8 of its weight For this reason they do not require seasoning in order to arrive at a sufficiently adequate degree of heat yield THE USE OF EXPIRED PELLETS OR ANY OTHER MATERIAL WILL AFFECT THE FUNCTIONALITY OF YOUR GENERATOR AND MAY LEAD TO THE TERMINATION OF THE WARRANTY AND CESSATION OF ANY ACCOMPANYING RESPONSIBILITY...

Страница 11: ...es the stove modulation On the stove is working at the set power Flashing the power at which the stove is working is different to the power set the stove is modulating for various reasons Indicates the contact of the external additional thermostat Contact closed the contact of the external additional thermostat is closed and the STBY function is disabled Contact open the contact of the external ad...

Страница 12: ...st be full of pellets The combustion chamber must be clean The burn pot must be completely free and clean Check the hermetic closure of the fire door and the ash drawer Check that the power supply cable is connected correctly The bipolar switch in the rear right part must be positioned on 1 It is FORBIDDEN to use the appliance without the divider AND OR GLASS PROTECTION see the figure to the side ...

Страница 13: ...yed automatic shutdown 8 Menu This key allows the user to access the user and technical menu the technical menu is reserved for assistance 9 Increase The temperature setting can be increased by pressing this key 10 ESC key The key allows the user to exit any program or display and returns to the main menu without saving the data 11 Back The key returns to the display of the various menus 12 Confir...

Страница 14: ...et clock will appear Confirm using key 6 Use keys 4 and 5 to select the day Proceed by pressing key 2 With the same procedure use keys 4 or 5 to set and key 2 to move forward to adjust the hours minutes day month and year Press key 6 to confirm and key 1 to return to the previous menus up to the initial status Set clock Day Mon Tue Wed Sun Hours 0 23 Minutes 00 59 Date 1 31 Month 1 12 Year 00 99 A...

Страница 15: ... level Power 5 maximum level Work with Room Probe STANDARD The appliance controls the room temperature via a probe fitted on the appliance Having reached the set temperature it will automatically go to the minimum or switch off activating the Stand by function reducing pellet consumption to a minimum In the factory the STBY function is always set to OFF indicator on For its activation and logic fo...

Страница 16: ...roblems correlated to the amount of fuel can be divided into 2 categories No fuel the stove can never develop a suitable flame tending to remain very low even at high power at minimum power the stove tends to almost switch off taking the stove into no pellets alarm condition when the stove displays the no pellets alarm there may be non burned pellets inside the burn pot Excess fuel the stove devel...

Страница 17: ...me Monday Sunday On off Enable disable the days of PRG1 Set prg1 LOW 07 40 C PRG1 temperature Start prg2 OFF 00 00 23 50 PRG2 ignition time Stop prg2 OFF 00 00 23 50 PRG2 switch off time Monday Sunday On off Enable disable the days of PRG2 Set prg2 LOW 07 40 C PRG2 temperature Start prg3 OFF 00 00 23 50 PRG3 ignition time Stop prg3 OFF 00 00 23 50 PR3 switch off time Monday Sunday On off Enable di...

Страница 18: ...ill go off after a preset delay The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine Controls procedure Press key 6 Proceed by pressing key 2 until settings is displayed Confirm using key 6 Press key 2 until display is shown and use key 6 to confirm Press key 2 until brightness appears and confirm with key 6 Use keys 4 5 to set the brightness Pres...

Страница 19: ...itional thermostat The Stby function is used if immediate stove switch off is required when the set temperature has been reached By default the Stby function is always set to OFF indicator on Stby function set to OFF FACTORY SETTING Should the Stby function not be active OFF if the stove reaches the room temperature set on the additional thermostat contact open it will go to minimum modulating and...

Страница 20: ...To install and enable it A mechanical or digital thermostat is required Remove the plug from the socket Referring to the figure to the side connect the two thermostat wires dry contact not 220 V on the relative terminals at the back of the machine one is red and the other one is black Power the stove Press key 5 setting the temperature on LOU The stove is now configured correctly It will work cont...

Страница 21: ... module With an internet connection it allows for remote monitoring and control of the stove via Smartphone For further information consult the manual contained in the WiFi remote control module box WiFi remote control module Total Control application RESET CONFIG INTERNET ACCESS POINT SERVER REMOTO POWER SERIAL 12VDC 21 ...

Страница 22: ...er use abrasive or chemically aggressive detergents to clean Surfaces must be cleaned when the generator and covering are completely cold To carry out maintenance on surfaces and metal parts just use a cloth dampened with water or water and neutral soap Failure to comply with the directions can damage the generator s surfaces and void the warranty Cleaning the ceramic glass Never use abrasive or c...

Страница 23: ...er and ash drawer Every 3 4 days check and remove the ash drawer and empty it into a designated container The ash drawer content must be emptied at least once twice a week Vacuum the combustion chamber in its entirety Vacuum the area underneath the removable ash drawer Once you have cleaned it re position the removable drawer and close the door The images are for illustration purposes 23 ...

Страница 24: ...ection to the flue Vacuum and clean the pipe that leads to the flue yearly or whenever necessary If there are horizontal sections any residue must be removed before it obstructs the flue Putting the equipment out of service end of the season At the end of every season before turning off the stove we recommend completely emptying the pellet tank and using a vacuum cleaner to clear up any pellets an...

Страница 25: ...Inspection of gaskets ash drawer and burn pot door replace them and apply silicone where required C Room air fan disassembly and removal of dust and any pellet debris D Fumes motor disassembly and cleaning and fumes pipe new silicone in required points E Fumes box inspection opening deposited waste complete intake F Tank complete emptying and cleaning 25 ...

Страница 26: ...ernal thermostat in stand by for re ignition To deactivate the STAND BY function see the specific chapter Cooling stand by A new ignition is attempted when the stove has just been switched off When the stove switches off it is necessary to wait until complete fumes motor switch off and then clean the burn pot The stove can only be re ignited when these operations have been performed Cooling stdby ...

Страница 27: ...r the presence of pellets in the feed box Adjust pellet flow see Pellet feed adjustment Check the procedures described in the Ignition chapter Other restoration operations must be carried out by an authorised technician Black Out No Ign No current during the ignition phase Take the stove to off conditions using key 1 and repeat the procedure described in the Ignition chapter Other restoration oper...

Страница 28: ...lity to use the product and wrong maintenance by the consumer with respect to what is reported and recommended by the instructions manual of the product which is part of the sales contract this guarantee will be void Damage to the product that cannot be related to manufacturing defects are also not included in this guarantee Similarly are excluded defects related to incorrect operation of the flue...

Страница 29: ...et pipes etc Please therefore avoid coming into contact with these parts without wearing suitable protective clothing or using appropriate measures such as heat protective gloves DO NOT use the product with the door open or if the glass is broken The product must be electrically connected to a system equipped with an operational earthing system Turn off the product in the event of a failure or mal...

Страница 30: ...ENGLISH 30 ...

Страница 31: ...ENGLISH 31 ...

Страница 32: ...info extraflame it www lanordica extraflame com 004276500_MU_GLENDA_WIFI_002 06 10 2015 The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice in order to improve its products This manual cannot be considered as a contract for third parties ...