USER MANUAL 

 

 

 
Wireless Datalogging CAT IV True RMS Multimeter 

  
Model MM750W 

 

 

 

Содержание MM750W

Страница 1: ...USER MANUAL Wireless Datalogging CAT IV True RMS Multimeter Model MM750W...

Страница 2: ...NTS 10 AC VOLTAGE FREQUENCY DUTY CYCLE MEASUREMENTS 10 DC CURRENT MEASUREMENTS 11 AC CURRENT FREQUENCY DUTY CYCLE MEASUREMENTS 12 CLAMP ADAPTOR MEASUREMENTS AC DC 13 RESISTANCE MEASUREMENTS 14 CONTINU...

Страница 3: ...W Series application Rated CAT IV 600V CAT III 1000V Safety This symbol adjacent to another symbol terminal or operating device indicates that the operator must refer to an explanation in the Operati...

Страница 4: ...e operating the meter Always remove the test leads before replacing the battery or fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Use grea...

Страница 5: ...nnect the meter leads across a voltage source while the function switch is in the current resistance or diode position doing so can damage the meter 5 ALWAYS discharge filter capacitors in power suppl...

Страница 6: ...Control buttons 4 Function switch 5 Positive 10A input terminal 6 COM negative input terminal 7 Positive terminal for all inputs except 10A METER BACK 1 Wireless module compartment 2 Test lead holders...

Страница 7: ...or data transmission ON OFF Short press to select one of the functions available for a given rotary switch position Long press while powering up to defeat Auto Power OFF APO Short press for Data Hold...

Страница 8: ...t the desired range manually before entering MAX MIN mode If the reading exceeds that range OL will appear Auto Range mode will re activate when you exit MAX MIN mode 1 Short press MAX MIN to activate...

Страница 9: ...before automatically powering off after which the meter loudly beeps once as it switches off To wake the meter press the M button no need to turn the rotary switch To disable APO press and hold the M...

Страница 10: ...some 240V outlets As a result the reading may show 0 volts when the outlet actually has voltage Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no volta...

Страница 11: ...tch to the A position and insert the red test lead banana plug into the A mA jack 3 For current measurements up to 600mA DC set the function switch to the mA position and insert the red test lead bana...

Страница 12: ...or current measurements up to 600mA AC set the function switch to the mA position and insert the red test lead banana plug into the A mA jack 4 For current measurements up to 10A AC set the function s...

Страница 13: ...lamp adaptor s positive lead to the meter s positive jack 5 The meter displays 1A per each mV input for example with a 3mV input the meter will display 3A 6 Take a current measurement with the externa...

Страница 14: ...connect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 5 Read the resistance in the display CONTINUITY CHECK WARNING To avoid electric shock...

Страница 15: ...ear 0V and an open device will indicate OL in both polarities CAPACITANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before takin...

Страница 16: ...or leave in open air 7 Read the temperature on the display Use the M button to select o C or o F NCV NON CONTACT EF VOLTAGE MEASUREMENTS WARNING Check the NCV function on a known live circuit before t...

Страница 17: ...and secure with the two screws before use OBTAINING THE APPLICATION APP For iOS devices download the ExView W application from the Apple App Store For Android devices download the ExView W applicatio...

Страница 18: ...nd on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment an...

Страница 19: ...te As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dis...

Страница 20: ...6 000A 0 001A 1 5 reading 5 digits 10 00A 15 secs 0 01A AC Current 600 0 A 0 1 A 0 15 reading 5 digits 6000 A 1 A 60 00mA 0 01mA 600 0mA 0 1mA 6 000A 0 001A 1 5 reading 5 digits 10 00A 15 secs 0 01A...

Страница 21: ...ions consist of two elements of reading Accuracy of the measurement circuit digits Accuracy of the analog to digital converter AC Response True RMS responding Input Impedance 10M ohm for Voltage AC DC...

Страница 22: ...n 2012 04 ELECTRICAL EQUIPMENT FOR MEASUREMENT CONTROL AND LABORATORY USE Part 1 General Requirements IEC 61010 1 2010 3rd Edition IEC 61010 2 033 Edition 1 0 2012 04 Approvals CE Contact Customer Sup...