manualshive.com logo in svg
background image

 

 

 

User’s Guide  

 

 
 
Model 401050 AC/DC Voltage Detector 

 

 

Safety Precautions 

1.  Improper use of this meter can cause damage, shock, injury or death. Read this guide before use. 
2.  The tester should not be used to test voltages above the stated ranges. 
3.  Secure the battery compartment screw before use. 
4.  Inspect the condition of the tester for any damage before use. 
5.  Remove the batteries from the meter if the meter is to be stored for long periods. 
6.  For Indoor use only 

International Safety Symbols 

Refer to the user’s guide for information.                Hazardous voltages may be present

 

 

 

Battery Replacement 

1.  Using a screwdriver, remove the battery compartment screw cap (end 

of handle) to access the batteries. 

2.  Remove the spring from inside the battery compartment and set it 

aside. 

3.  Remove the batteries, noting their polarity and orientation. 
4.  Insert the two new LR41 batteries in the same orientation and polarity. 

The po side of both batteries must be facing up toward the 
opening of the battery compartment. If the batteries are not replaced in 
this position, the instrument will not operate. 

5.  Replace the battery compartment spring. 
6.  Replace and secure the compartment screw cap. 

 

Specifications  

AC Voltage (contact) test…………. 70 to 250VAC 
AC Voltage (non-contact) test….... 70 to 600VAC (single sheathed insulation, single conductor) 
DC Voltage / Polarity test……..….. 1.5V to 36V  
Continuity test………………..……. 0 to 5M ohms 
Batteries………………………...….. Two (2) LR41 

  

Battery

Compartment

Positive
side
up

Отзывы: