background image

1

 

 

 

 

 

 

Thank  you  for  purchasing  this  8-line  Digital  I/O  to  Ethernet  Adapter 
(hereinafter  referred  to  as 

“Adapter”

).  It  is  designed  to  adopt  your 

digital I/O lines remotely on your Ethernet (Internet). It delivers simple, 
reliable  and  cost-effective  network  connectivity  for  your  digital  I/O 
applications such as home or industrial factory automation, digital I/O 
control  from  any  networked  PC,  alarm  and  power  monitoring  by 
network  or  Internet,  PC  controlled  machines,    distributed  machine 
I/O, remote lighting and power control etc. 

Features: 

 

4 Digital Input and 4 Output Lines over a 10-pin Terminal Blocks 

 

2 Non-inverted and 2 Inverted Output Lines 

 

Provides ESD and Surge Protection for all I/O Lines 

 

I/O Line Voltage is Compatible with CMOS/TTL 

 

Provides one 10/100Mbps, RJ45 LAN Port 

 

Provides TCP Server, TCP Client, and I/O Extender Modes 

 

P5VDC by DC Jack or Terminal Blocks 

 

Provides both Wall Mounting and DIN RAIL Kits 

 

Supports Virtual COM Port Drivers 

 

 
 
 

 

 

 

 

 
  
 

DIO Lines Terminal 
Blocks 

EX-6011 

8-line Digital I/O to Ethernet Adapter, w/ DIN 

RAIL Mounting Kit 

1. Introduction 

2. Connector Layout 

+5VDC Power 
Input DC Jack 

RJ45 LAN 
Connector 

Switch to Restore 
Default Settings   

Содержание EX-6011

Страница 1: ...emote lighting and power control etc Features 4 Digital Input and 4 Output Lines over a 10 pin Terminal Blocks 2 Non inverted and 2 Inverted Output Lines Provides ESD and Surge Protection for all I O...

Страница 2: ...5V OUTPUT If the DC Jack is unconnected it can be powered by this pin with 5V input power Switch to Restore Default Settings This switch can be used to reset the product to its factory default setting...

Страница 3: ...is can be accomplished by touching a bare metal chassis rail after you have turned off the power 2 Attached the power adapter 5V DC power needs to be connected to either the DC jack or the Terminal Bl...

Страница 4: ...refer to the following sections After that the Adapter will send a DHCP request to the DHCP server which will assign a dynamic IP address net mask and gateway to the Adapter the first time it is conne...

Страница 5: ...ress using Web Browser Please make sure your PC s IP address is set at the same subnet of the Adapter If not you usually need to change your PC s IP address from Local Area Connection Properties here...

Страница 6: ...sword Then go to change your IP address as well other parameters if required 3 Setting the IP address using Em exe Utility The Em exe is a Microsoft Windows based utility to find all the Adapters conn...

Страница 7: ...disable your firewall or the anti virus software then try again 4 The Adapter Settings When you entered Setup Menu of the Adapter the following page will be available for your access Please click Upda...

Страница 8: ...ned by the DCHP server if DHCP client is enabled DHCP client If disable then IP address Subnet mask and Gateway address must be assigned manually Socket port of HTTP setup Port number for HTTP Setup M...

Страница 9: ...s Device ID User assigned device ID number acceptable range is 0 to 65535 Device Name 16 characters maximum to describe the application facility Device Model 16 characters maximum to indicate the appl...

Страница 10: ...ine Digital I O to Ethernet Adapter 10 1 Launch the HyperTerm utility it will create a new connection please type the connection name type a in this case 2 Enter the Adapter s IP address and port numb...

Страница 11: ...rn and a line feed indicating the current state of all 8 DIO lines 11111111 for example The string is formatted as the following table 1 1 1 1 1 1 1 1 4 In HyperTerm click File Properties Settings ASC...

Страница 12: ...re are four legal values 01 02 03 and 04 m 0 or 1 0 means to drive the I O pin to LOW state 1 means to set the I O pin to HIGH state Stands for 2 characters a Carriage return and a Line feed 0x0D and...

Страница 13: ...to the following screen shot it was actually tested with a short wire to ground the DI_0 DI_1 DI_2 then DI_3 pins sequentially You will see it detected 0 when grounded then 1 when released sequential...

Страница 14: ...anywhere in the world via Internet or LAN as if it is attached directly to the remote PC When the attached serial port device or digital I O Adapter sends communication data it is actually transmitte...

Страница 15: ...Adapter 15 2 While installing the driver please enter the password 3 Follow the on screen instructions to complete the Installation you are ready to launch the software utility to enter the hardware...

Страница 16: ...at CentosSEC should be run as an administrator for some Windows such as 2008 Vista and 7 their UAC User Account Control will limit the CentosSEC from working properly if you have only standard user pr...

Страница 17: ...following screen will appear click the Help button will list the supported operations and details You may need to click Add to create a new COM port then click Update All to save the settings You don...

Страница 18: ...Net Protocol to RAW instead of TELNET for this digital I O Adapter After clicked Update All button the status field should become Available If it is Registered it won t work properly You need to revi...

Страница 19: ...e digital IO lines remotely without any extra software or drivers TCP Server mode The TCP Server mode provides the service at the TCP IP socket port The default setting of this Adapter is set at 192 1...

Страница 20: ...2 168 1 254 port 100 the Slave unit should set its Destination IP to match the Master s service port 192 168 1 254 port 100 In this mode the IO pins are remotely connected without any software support...

Страница 21: ...r Slave Configuration The Slave unit settings included its IP address 192 168 1 252 must be different from the Master unit mode IO Extender Slave and Destination IP port Master unit s IP port 192 168...

Страница 22: ...mption Mechanical Specifications Material Gross Weight Environmental Operating Temperature Storage Temperature 10 100Mbps Ethernet RJ45 10 100Mbps 4 TTL CMOS Input Lines DI_0 to DI_3 4 TTL CMOS Output...

Страница 23: ...ne Digital I O to Ethernet Adapter 23 Operating Humidity 5 to 95 RH Electrical Characteristics Parameters Values Input DI_0 DI_1 DI_2 DI_3 Low High 0 8V 2 0V Output DO_0 DO_1 DO_2 DO_3 Low High 0 55V...

Страница 24: ...8 line Digital I O to Ethernet Adapter 24...

Отзывы: