background image

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

PC 111

Catalog No. 533-80052

Printed in U.S.A.

Form OM38/40-2

Pg 1

2-02

Replaces: OM38/40-1

Book 1

4

Tab

3e 2f

OWNER’S MANUAL

38CG,CS018-030

40CG,CS018-030

Wall Console/Underceiling Duct Free Systems

CONTENTS

Page

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,3

OPERATING MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
REMOTE CONTROL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-7

REMOTE CONTROL OPERATION . . . . . . . . . . . . . . . . 3
UNIT OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

CLEANING AND MAINTENANCE  . . . . . . . . . . . . . . .7,8

AIR FILTERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Page

INDOOR UNIT FRONT PANEL . . . . . . . . . . . . . . . . . . .  7
INDOOR UNIT COIL  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
OUTDOOR UNIT COIL  . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CONDENSATE DRAINS  . . . . . . . . . . . . . . . . . . . . . . . . .  8
SYSTEM OPERATION CHECK LIST . . . . . . . . . . . . . . 8
DIP SWITCH SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . 8
ENERGY SAVING RECOMMENDATIONS. . . . . . . . . 8

TROUBLESHOOTING GUIDE  . . . . . . . . . . . . . . . . . . . . 9

II

II

II

I I I I I I I

I

II

II

MODE

FAN

SWEEP

A

A

S TA RT

S TO

P

1     2       3  

S L E E P

D A I LY

Содержание 38CG

Страница 1: ...ll Console Underceiling Duct Free Systems CONTENTS Page INTRODUCTION 2 GENERAL 2 3 OPERATING MODES 2 REMOTE CONTROL 2 OPERATION 3 7 REMOTE CONTROL OPERATION 3 UNIT OPERATION 7 CLEANING AND MAINTENANCE 7 8 AIR FILTERS 7 Page INDOOR UNIT FRONT PANEL 7 INDOOR UNIT COIL 7 OUTDOOR UNIT COIL 8 CONDENSATE DRAINS 8 SYSTEM OPERATION CHECK LIST 8 DIP SWITCH SETTINGS 8 ENERGY SAVING RECOMMENDATIONS 8 TROUBLE...

Страница 2: ... temperature of room air is lower than set point the system will operate in Heating mode If temperature of room air is higher than set point the system will operate in Cooling mode Remote Control The remote control transmits com mands to set up and operate the system The controller has a window display panel that shows the current system status The controller can be secured to a surface when used ...

Страница 3: ...UP DOWN button until desired temperature appears on screen The symbol appears each time the ON OFF button is pressed Another way of changing the temperature is as follows 1 Select the temperature display by pressing the MODE button The degree symbol will flash next to the digits on the screen 2 Press UP DOWN button to select the desired tempera ture The available temperature range is from 54 F to ...

Страница 4: ...e TIMER or SET buttons beep I I I I I II I I I I I I I I I I I MO DE FA N SW EE P A A S TA R T S TO P1 2 3 S L E E P DA I LY UNIT REMOTE TEMPERATURE SENSOR TRANSMISSION INDICATOR LOW BATTERY INDICATOR UP DOWN BUTTON DESIRED TEMPERATURE SENSOR ACTIVE INDICATOR SWEEP INDICATOR ON OFF BUTTON CLOCK BUTTON ROOM TEMPERATURE BUTTON DELAY BUTTON LOCAL SENSING BUTTON INFRARED SIGNAL TRANSMITTER WINDOW CLOC...

Страница 5: ...y Timer program 1 Slide down front cover of controller below ON OFF but ton See Fig 4 2 Press the TIMER button to select the time period that will be activated daily 3 Press the SET button and hold until the word DAILY disappears on the display 4 Press the SET button again to remove the daily operation from the selected time period Be sure to point remote control toward the unit while pressing the...

Страница 6: ...uctions in Canceling Specific Start Stop Time Period section NOTE The Delay setting is stored in Time period 3 LOCAL SENSE FUNCTION 2 Way Remote Control The local sense function allows the remote control to operate by transmitting the room air temperature to the unit at regular intervals from wherever the controller is located in the room The unit will then operate to make the air near the remote ...

Страница 7: ... the indoor unit coil remove the front panel and vacuum the coil fins Avoid bending or damaging the fins To avoid the possibility of electric shock always turn off power to the system before performing any cleaning or maintenance to the system Turn off the outdoor disconnect switch located near outdoor unit Be sure to disconnect indoor unit if on a separate switch Operating the system with dirty a...

Страница 8: ...n the battery compartment two of which control special system characteristics See Fig 16 The DIP switch default positions are set according to the model air conditioner installed as per the following table Switch No 3 should be set as follows OFF default When only one air conditioner is installed in the room ON When there are two air conditioners with remote controllers installed in the room in on...

Страница 9: ...when operating in the HEATING mode The control system is malfunctioning There is no direct line of sight between the remote control and the unit Lower the desired temperature setting Raise the desired temperature setting Move the operation switch to OFF then REMOTE Place the remote control where there is a direct line of sight to the unit Various indicator lamps behave other than listed in previou...

Страница 10: ...__________________________________________________ Telephone _________________________________________ Purchase _____________________________________________ Indoor Model _____________________________________ Outdoor Model _______________________________________ Indoor Serial _____________________________________ Outdoor Serial _______________________________________ ...

Страница 11: ......

Страница 12: ...nue or change at any time specifications or designs without notice and without incurring obligations PC 111 Catalog No 533 80052 Printed in U S A Form OM38 40 2 Pg 12 2 02 Replaces OM38 40 1 Copyright 2002 Carrier Corporation Book 1 4 Tab 3e 2f ...

Отзывы: