EZMultiPli

 

                   Z-Wave Wireless Plug-In Multi-Sensor  

Motion – Light - Temperature - Color Indicator 

www.ExpressControls.com 

 

November 2014

 

The Quick and Easy Way to Control Your Home 

 
 
 

EZMultiPli

  

Z-Wave Wireless Plug-In Multi Sensor:  

Motion Sensor 
Light Sensor 
Temperature Sensor 
Color Indicator/Night Light 
Wall Powered 
Z-Wave Range Extender 

 

Features

 

Motion Sensor 
 

Passive Infrared Sensor (PIR) 

 

12

’ range 

 

90

 coverage 

 

Programmable timeout 

 

Direct control of up to 4 associated devices 

Temperature Sensor 
 

20

 - 150

F range 

 

0.2

F resolution 

Light Sensor 
 

Relative light level 0-100% 

Color Indicator Night Light  
 

Eight colors 

 

White, red, green, blue, aqua, yellow, pink, black  

Wall Powered 
 

120VAC 60Hz 1Watt 

 

No wires - just plug it in 

 

Never needs batteries 

Z-Wave

®

 Wireless RF Communication 

 

Advanced mesh-network protocol 

 

Range extender improving network for all nodes  

 

300’ RF range line-of-sight 

 

100,000 bits/sec 
Up to 4 associated Z-Wave nodes 
Network wide inclusion  
Over the air firmware update 

 

Fifth generation radio technology 

 

Pushbutton to factory reset or join network 

Designed and assembled in USA 
 
 
 
 
 

 

Содержание EZMultiPli

Страница 1: ...trol of up to 4 associated devices Temperature Sensor 20 150 F range 0 2 F resolution Light Sensor Relative light level 0 100 Color Indicator Night Light Eight colors White red green blue aqua yellow pink black Wall Powered 120VAC 60Hz 1Watt No wires just plug it in Never needs batteries Z Wave Wireless RF Communication Advanced mesh network protocol Range extender improving network for all nodes ...

Страница 2: ...emperature Report 5 LED Color 5 Z Wave Range Extender 5 Configuration Parameters 6 Technical Information for Software Developers 6 Inclusion Interview 6 Notification Command Class 7 Association 7 Multilevel Sensor Reports 8 Light Level Sensor 8 Temperature Sensor 8 Configuration Command Class 8 Color Switch Command Class 9 Firmware Update Command Class 9 Troubleshooting 12 Regulatory Information 1...

Страница 3: ...as well as the current temperature The color LED light within EZMultiPli is a convenient night light or can be used as an indicator light to let you know if the weather forecast is predicting rain your garage doors are open or any other indicator supported by your home control application EZMultiPli is wall powered and needs no wires or batteries Simply plug EZMultiPli into the wall join the Z Wav...

Страница 4: ...rocess Once the primary controller is ready to receive the exclusion command press and release the push button on the side of EZMultiPli The primary controller should give an indication that the reset process has completed EZMultiPlis LED will blink aqua when it is ready to be added to a Z Wave network Always ensure a device is not already joined to a Z Wave device before trying to add it to a Z W...

Страница 5: ...y moving the OnTime can be set to 5 minutes to turn the lights off as shortly after they have left the hallway Light Report EZMultiPli sends a report of the relative amount of light currently in the room to the Z Wave system controller The value is from 0 to 100 and is relative to the maximum and minimum amount of light EZMultiPli has measured since it was plugged in The reports are automatically ...

Страница 6: ...f zero turns this mode off Temperature values can still be obtained at any time by polling the status of the temperature sensor 0 127 5 TempAdj Factory Default TempAdj is a twos complement number that is used to adjust the temperature reading to make it more accurate The value is in tenths of degree Fahrenheit The temperature reading can be adjusted by 12 7F to 12 8F A value of 1 will adjust the t...

Страница 7: ...ld result in a poor user experience By sending the commands without routing the commands are sent to all 4 nodes within a fraction of a second Once the commands have been sent to group 2 then a Notification Report is sent to association group 1 which is typically the system controller node The Notification Report is sent with full routing including explorer frames if necessary Note that assigning ...

Страница 8: ..._MULTILEVEL_GET command By default the scale is Celsius The application software should convert the report to the users desired temperature scale Name Value HEX Description Command Class 31 COMMAND_CLASS_SENSOR_MULTILEVEL Command 05 SENSOR_MULTILEVEL_REPORT Sensor Type 01 Temperature Sensor Scale 22 or 2A 22 Celsius 2A Fahrenheit One digit of fractional precision Sensor Value MSB Signed 16 bit val...

Страница 9: ...ever cancels motion testing mode and the color will remain A BASIC_SET command turns the LED on white or off Firmware Update Command Class The firmware of EZMultiPli can be updated in the field by the customer using the Firmware Update Command Class An Intel Hex file of the Over The Air firmware can be obtained from the Express Controls web site It is strongly recommended to bring EZMultiPli withi...

Страница 10: ...y 40 bytes 8 Device validates the checksum of the received data and stores it in NVM increments the report number and sends FIRMWARE_UPDATE_MD_GET Repeat steps 7 8 for each block of data Both sides must have timeouts and retry blocks that failed to reach the other side Either side may get duplicates so the report number must be checked and if the sequence is incorrect the command should be discard...

Страница 11: ...eds updated firmware 11 Wait for the SEND of the REPORT to complete and the callback to acknowledge that the report was sent Enable the watchdog with ZW_WatchdogEnable then execute a WHILE 1 and wait for the watchdog to reset the chip The bootloader will identify the new firmware and copy it to flash This process takes several seconds The device then reboots again and should now be running the upd...

Страница 12: ...e adjusted using TempAdj Configuration Parameter Devices far away are not controlled by EZMultiPli Devices in association group 2 must be less than 30 feet from EZMultiPli For devices that are further away or are blocked by metal or concrete walls use the Z Wave system controller to control those devices Motion sensor doesn t work Two things have to be setup for a system controller to receive moti...

Страница 13: ... ETL control number for EZMultiPli is 4010942 Safety Standards UL 60950 1 Issued 2007 03 27 Ed 2 Rev 2011 12 19 Information Technology Equipment Safety Part 1 General Requirements CSA C22 2 60950 1 Issued 2007 03 27 Ed 2 R2012 Information Technology Equipment Safety Part 1 General Requirements Amendment 1 2011 Warranty Information LIMITED 2 YEAR WARRANTY If within two 2 years from the date of purc...

Страница 14: ...Accuracy 2 0C 10C to 80C Temperature Resolution 0 1C Light Sensor 0 100 Relative LED 8 colors Dimensions 3 25 H x 1 9 W x 1 9 D Weight 50g Z Wave Command Class Support Routing Slave Enhanced 232 ZWavePlus Notification Alarm command class version 3 Multilevel Sensor V6 Luminance Temperature Color Control Manufacturer Specific Version Association Group Info Association Configuration Node Naming Devi...