Choose Run Mode
The
operating mode
is
set in menu
RUN
. For operation on a DMX-controller
DMX
needs to be
set.
SLAVE
sets the fixture into slave mode.
MENU
E-27
PERSON
RUN
HSIC
DMX
HSIC
SLAVE
Miscellaneous Settings
MENU
PERSON
SETTING
HSIC
RESET
HSIC
COLOR
HSIC
DIMMER
HSIC
DMX ERROR
HSIC
PERFORMANCE
HSIC
MCON
****
UC
OFF
RGBtoW
DIM4
DIM3
DIM2
DIM1
OFF
SAVE
BLACK
LIVE
STUDIO
SELF
MASTER
HSIC
SEND
UPLOAD
****
****
HSIC
RESET
POWER
HSIC
PWM_RATE
600HZ
1200HZ
2000HZ
4000HZ
6000HZ
25000HZ
HSIC
FULL POWER CCT
3200K
4200K
5600K
10000K
NORMAL
The default password is: UP - DOWN - UP - DOWN - ENTER
UPLD
: sends the user programs to connected slave fixtures.
RESET
: sets all editable settings back to factory default.
COLOR:
in this submenu a colour calibration is selected or deactivated. When
UC
is selected the
Uniform-Colour factory calibration is used, which adjusts devices of different generations. When
RGBtoW
is selected, the maximum brightness values at DMX = 255 are limited to the values set in
CALIB.C
\
RGBtoW
. If the value is set
OFF
, the calibration is deactivated and the device reaches the
maximum brightness.
DIMMER:
controls different dimming speeds to simulate a halogen bulb (
DIM4/DIM3/DIM2/DIM1/
OFF
).
DMX ERROR:
sets how the fixture responses if DMX-signal gets lost. Set
SAVE
to hold the last
received value or
BLACK
for blackout.
PERFORMANCE:
gives the user the opportunity to change the performance of the fixture between
LIVE
,
STUDIO
and
POWER.
MCON:
sets if the fixture is a master and sends data to other fixtures (
MASTER
), or not (
SELF
).
Содержание led22940
Страница 6: ...Abmessungen...
Страница 15: ...Dimensions E 22...
Страница 28: ...2018 by Focon Showtechnic Vertriebsgesellschaft mbH...