50
13.3 SAFETY RECOMMENDATION
The following safety recommendations are not compulsory, contrary to the previous ones, but should
still be adhered to if possible
13.3.1 EMERGENCY SHUT OFF
We generally recommend to use the devices with 230VAC mains voltage, and add an emergency shut
off switch into the supply line, to switch them off at any time.
Optionally, a DMX switchbox, which controls the 230VAC power line, can be used as a DMX capable
emergency shut off.
13.3.2 DRIP PAN
If the device is placed on flammable ground, or the ground is to be protected (eg. stage floorings, ice
rings), we recommend using a drip pan, placed underneath the device. This pan should catch any
fluids that may leak from the system.
The pan space should be at least 70 x 50cm with a depth of 5cm.
13.3.3 INTERRUPTING AN AUTOSHOW
To interrupt an AutoShow, the Wave Flamer must receive a "Pause", "Disarm" or "Test" signal. During
a predefined sequence, an incoming signal will be received, but the current sequence will be finished.
To guarantee a stop, a test signal should be sent until the device das no longer ignite, or the timeout
be set accordingly.
13.4 SAFETY HINTS
The device may only be used if it is in a proper state and well maintained. Defective devices must be
checked and repaired by teh manufacturer, or other authorized person. Under no circumstances may
defective devices be used.
After longer storage, the Wave Flamers should be checked for function and leak tightness before
usage.
The devices are to be placed atop firm ground. It should be placed horizontally on the floor, and be
protected against tipping. If a tripod is used, it must be proofed against tipping.
Should any flammable materials be close to the flame direction, we recommend checking the safety
distances with the local authorities and fire department.
After turning the device on, no persons may linger in the vicinity of it. All persons taking part in the
show (Helpers, actors,...) are to be informed about the safety distances and basic functions of the
device.
During the show, it is possible that small amounts of unmisted fluid fall to the ground. These evaporate
normally and should pose no threat.
The person in charge of the devices control must have a clear sight of them at any time. Ideally via a
direct line of sight, alternatively however via cameras. This person is in charge of making sure the
safety distances are adhered to at any time during the show, and be able to interrupt it if needed.