Страница 1: ...EX 9543 Enhanced 10 100Base TX to 100Base FX Media Converter User Manual ...

Страница 2: ...rmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at th...

Страница 3: ...ion 5 Product Overview 5 3 Installation 7 Location 7 DIP Switches 8 NWay DIP Switch Setting 9 Link Fault Signaling LFS 11 Loopback Test 12 Local Loopback 13 Remote Loopback 14 Install the converter 15 Desktop Installation 16 Getting Connected 17 Connecting Fiber Cable 18 Connecting Copper Cable 19 4 LED Indicators 20 Appendix A 22 Cables 22 Appendix B 23 ...

Страница 4: ...ackets 24 Installing the Converter 26 Rear view of Chassis and specifications 27 Rear View of Chassis with AC Power Supply 27 Rear View of Chassis with DC Power Supply 27 Appendix D 28 Application Diagrams 28 Application Diagram I 28 Application Diagram II 29 Application Diagram III 29 ...

Страница 5: ...ce integrates copper and multi mode single mode fiber networks in one flexible package Purpose This guide discusses how to setup and install your Enhanced 10 100Base TX to 100Base FX Converter Terms Usage In this guide the term Converter first letter upper case refers to your Enhanced 10 100Base TX to 100Base FX Converter and converter first letter lower case refers to other converters ...

Страница 6: ...Test via DIP switch When DIP switches are set the system auto reboots to new configurations without powering off Extends distance of up to 2km 6600 feet multi mode fiber and 60km 198000 feet long haul single mode fiber Compatible with other 10Base T 100Base TX FX devices LEDs for at a glance device status Suitable as stand alone or in 19 4 12 slot rack mount converter chassis or the single slot mi...

Страница 7: ...C types or 1x simplex fiber optic connector WDM single fiber types 1x UTP 100 120ohm RJ 45 type Max Distance UTP 100m Cat 3 4 5 Fiber Optic 2km MM dual fiber 60km Long haul SM dual fiber 20km 66000ft SM single fiber 40km Long haul SM single fiber Power External power supply 12V DC 0 5A Please see Appendix A for Internal Power Supply Temperature Operating 0 to 50 Celsius Storage 20 to 70 Celsius ...

Страница 8: ...09 2x 73 8x 23 4 mm L x W x H Switches for DIP 1 Auto negotiation RJ 45 DIP 2 Copper port duplex mode DIP 3 Copper port data bit rate DIP 4 Fiber port duplex mode DIP 5 Link Fault Signaling LFS DIP 6 Local Loop Back LLB DIP 7 Remote Loop Back RLB Package Contents One converter unit One AC adapter please check connector type Self adhesive pads 4 pieces User Manual ...

Страница 9: ... features automatic MDI detection setting This function allows for simple direct connection to a workstation switch or hub Therefore network managers no longer need to worry about cable type configuration when establishing a connection between RJ 45 ports This Converter is equipped with an RJ 45 port and a fiber optic ST or SC or WDM port This allows it to quickly integrate a 10 100Base TX network...

Страница 10: ... fiber and up to 60 kilometers for long haul single mode fiber between a LAN switch file server or another networking device Converter with SC and RJ 45 Connectors Converter with ST and RJ 45 Connectors Front Panel View Fiber Port LED Indicators Copper Port ...

Страница 11: ...electing a site we recommend considering the following rules Install the Converter in a fairly cool and dry place See Technical Specifications for the acceptable temperature and humidity operating ranges Install the Converter in a location free from strong electromagnetic field generators such as motors vibration dust and direct exposure to sunlight Leave at least 10cm of space at the front and re...

Страница 12: ...lex mode full or half duplex DIP 3 Copper port RJ 45 data bit rate 10Mbps or 100Mbps DIP 4 Fiber port duplex mode full duplex or half duplex DIP 5 Enables disables Link Fault Signaling LFS DIP 6 Enables disables Local Loop Back LLB DIP7 Enables disables Remote Loop Back RLB Notes All models in this series feature the above set of DIP switches ...

Страница 13: ...the ON position The Converter will automatically set the optimum speed and duplex mode on the copper segment Users can skip the settings for DIP switches 2 and 3 when NWay is activated If NO Set the NWay DIP switch to the OFF position Then Use DIP switch 2 to manually select between half HD and full duplex FD modes Use DIP switch 3 to manually select between 10Mbps or 100Mbps speeds Set NWay switc...

Страница 14: ...u experience the following problems please check if the NWay switch is properly set 1 The LNK link LED is not lit and the connection cannot be established 2 The LNK LED is lit and the connection is ok but cannot transmit or receive data 3 The converter functions properly for a while then it does not work And then it works after powering off and then on again Important In order to configure DIP swi...

Страница 15: ...r normal operational use Set LFS to OFF position when installing cables or when testing the network connection Note The LFS feature influences both fiber and copper segments Therefore when disruption occurs on either segment the LFS feature will be activated and the LED will light to indicate that the entire connection is down To appreciate the full benefits of LFS four converters can be used to b...

Страница 16: ...copper segment is connected properly and use remote loop back to check if the fiber segment is connected properly Please see Diagram below Dip Switch 6 ON enables local loop back function OFF disables local loop back function Dip Switch 7 ON enables remote loop back function OFF disables remote loop back function Make sure that the cables are connected properly before getting started Conduct eithe...

Страница 17: ...or diagnostics testing program and follow the instructions given Typically the instructions will be similar to the following a Enter the number of test messages frame packets to be sent Between 1 1000 b Click on the START button c The program will send a testing message looped in the copper segment and display a pass fail result DIP Switches 1 2 3 4 5 6 7 Converter A OFF FD 100 FD OFF ON OFF Conve...

Страница 18: ...ame packets to be sent Between 1 1000 b Click on the START button c The program will send a testing message looped in the fiber segment and display a pass fail result NOTE On a PC use a program such as Sniffer to conduct the tests Other methods include the use of SmartBits series testing equipment If you do not have access to either method please contact your vendor for advice DIP Switches 1 2 3 4...

Страница 19: ... automatic MDI MDI X crossover detection that gives true plug and play capability just plug in the network cable to the port and the port will adjust according to end node device automatically The RJ 45 connector is suitable for UTP cable Category 3 4 5 or better 100BASE FX Port The 100BASE FX port adds a fiber Fast Ethernet link to your network device Compliant with IEEE 802 3u this port can tran...

Страница 20: ...he Converter 3 Apply AC power to the Converter The green PWR LED on the front panel should light 4 Connect cables from the network partner devices to the ports on the front panel The green LNK LED on the front panel associated with the port should light This Converter can also be mounted on a vertical surface Simply use the underside of the unit as a template to measure and mark out the position o...

Страница 21: ...national use you may need to change the AC power adapter cord You must use a power cord set that has been approved for the receptacle type and electrical current in your country Warning Please exercise caution when using power tools Also install this unit away from damp or wet locations or in close proximity to very hot surfaces These types of environments can have a detrimental effect on the conv...

Страница 22: ...ctor is used Follow the steps below to properly connect fiber cable 1 Remove and keep the ST SC WDM port s rubber cover When not connected to a fiber cable the rubber cover should be replaced to protect the optics 2 Check that the fiber terminators are clean You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminator...

Страница 23: ...ort 6 Check the corresponding port LED on the Converter to make sure that the connection is valid Refer to the LED chart in next section Connecting Copper Cable The 10 100BASE TX RJ 45 Ethernet port fully supports auto sensing and auto negotiation 1 Insert one end of a Category 3 4 5 5e type twisted pair cable into an available RJ 45 port on the Converter and the other end into the port of the net...

Страница 24: ... have been designed to give easy at a glance network status and provides real time connectivity information Please see below for an interpretation of their functions Unit LEDs LED Condition Status On Green Converter is receiving power PWR Off Power off or failure On Red Disruption of connection in copper fiber segment LFS Off Copper fiber segment is OK ...

Страница 25: ...at 100Mbps 100 Off Port operating below 100Mbps On Green Illuminated when connectors are attached Flashing Green Data traffic passing through port LNK ACT Off No valid link established on port On Amber Port is operating at full duplex Flashing Amber Indicates collision FDX COL Off Port is operating at half duplex ...

Страница 26: ...r in network performs 2 4m m 6mm Try to maintain a bend radius of min 4x the diameter of the cable for UTP and 100x for fiber Try not to allow the cable to twist too much this creates a strain on the internal cables Place cable ties at regular intervals do not over tighten cable ties try to avoid using with fiber Do not stretch the cable especially on corners in vertical cable traysand when spanni...

Страница 27: ...10Base T configurations and Category 5 cable for 100Base TX The pin assignments are as follows Pin 1 TD Pair 2 White Orange Pin 2 TD Pair 2 Orange White Pin 3 RX Pair 3 White Green Pin 4 N A Pair 1 Blue White Pin 5 N A Pair 1 White Blue Pin 6 RX Pair 3 Green White Pin 7 N A Pair 4 Brown White Pin 8 N A Pair 4 Brown White Note Automatic MDI MDI X selection on RJ 45 port ...

Страница 28: ...n locations where space is limited Features Simple and easy to install Adds fiber connectivity to otherwise copper based networks Supports 10 100 1000Base copper fiber single multi mode ST SC MT RJ VF 45 LC WDM connector converters Supports one media converter Suitable for all size of networks in all locations Provides internal AC and DC switching power supply Made from high quality durable steel ...

Страница 29: ...Phillips screwdriver remove two screws from the side panels on the converter Step 2 Place the converter and brackets on a flat horizontal surface as illustrated above Secure the brackets by replacing the screws Ensure that the rails are flush mounted with the underside of the Converter The Converter is now ready for loading into the Chassis ...

Страница 30: ...ed into the Chassis Special care must be taken to ensure the correct mating of the power connector Align the Converter so that it fits between the upper and lower guide rails Warning Always ensure that the converter power socket is positioned at the base of the Chassis Never force the Converter into the Chassis check power socket position and alignment ...

Страница 31: ... of Chassis and specifications Rear View of Chassis with AC Power Supply Power 100 240V AC Optional 12V Adapter Dimensions 109 x 174 x 44 3 mm L x W x H Rear View of Chassis with DC Power Supply Power 48V DC Optional 12V Adapter Dimensions 109 x 174 x 44 3 mm L x W x H ...

Страница 32: ...nverters back to back as illustrated Application Diagram I In the figure below the Converter is functioning as a high speed bridge between switches creating increased capacity for each user node on the local area network It is providing a 100Mbps full duplex link to a variety of Fast Ethernet network devices within a LAN Switch CONVERTER CONVERTER Switch ...

Страница 33: ...providing a 100Mbps full duplex link to a workgroups of 10 100 switches located on separate floors within a single building Switch CONVERTER CONVERTER Server Application Diagram III In the figure below the Converter is functioning as a high speed dedicated link within a campus network configuration It is providing a 100Mbps full duplex link to a remote network node Switch CONVERTER CONVERTER Switc...

Отзывы: