background image

 

 EX-9132C-2RS485  

 

Serial to TCP/IP Converter

 

   

 
 

 

 
 

Version 1.2,14th Nov. 2012 

Содержание EX-9132C-2RS485

Страница 1: ...EX 9132C 2RS485 Serial to TCP IP Converter Version 1 2 14th Nov 2012 ...

Страница 2: ...rview 4 Package Checklist 4 Block Diagram 5 Features 7 Product Specifications 8 2 EX 9132C 2RS485 Description 10 Product Panel Views 10 Top Side 10 Right Side 11 Left Side 12 LED Indicators 13 Wiring Architecture 14 RS 232 14 RS 422 RS 485 14 ...

Страница 3: ...troller Updated 30 Factory Default Setting 31 4 Setting Verification 32 Hyper Terminal for TCP IP WinSock 33 Hyper Terminal for COM Port 38 Data Transmission 39 Appendix A FAQ 40 Appendix B Pin Outs and Cable Wiring 41 B 1 DC In Jack 41 B 2 RJ 45 Pin Assignment 41 B 3 RS 232 Pin Assignment 41 B 4 RS 232 Wiring Diagram 42 B 5 RS 422 Pin Assignment 42 B 6 RS 422 Wiring Diagram 42 B 7 RS 485 Wiring D...

Страница 4: ...oducts made network connectivity possible with affordable cost for virtually all kinds of devices EX 9132C 2RS485 is a full set converter device with two serial ports as one is a RS 485 422 port and another is a RS 232 422 485 Auto Detect and it provides one socket connection port This operation manual will guide you step by step to learn the various functions of the EX 9132C 2RS485 converter The ...

Страница 5: ...serves your software investment and let you enjoy the benefit of networking your serial devices instantly ARM Cortex M3 CPU series converter supports manual configuration via the handy web browser console and many protocols including TCP IP UDP HTTP DHCP ICMP and ARP They are the best solution to network your serial devices Package Checklist ARM Cortex M3 CPU products are shipped with the followin...

Страница 6: ...ta stream between network TCP IP and popular serial port signals Instead of processing TCP IP packets directly devices need only deal with those interface signals which greatly simplifies the complexity of TCP IP network in linkage The ARM Cortex M3 processor provides outstanding computational performance and exceptional system response to interrupt while meeting low cost requirements through smal...

Страница 7: ... 1 25 DMIPS MHz The ARM Cortex M3 processor also implements the new Thumb 2 instruction set architecture which combined with features such as unaligned data storage and atomic bit manipulation delivers 32 bit performance at a cost equivalent to modern 8 and 16 bit devices ...

Страница 8: ...tream or use the TCP IP package data to activate deactivate the specified digital outputs Dynamic IP Configuration Support DHCP client mode simplifying network address configuration and management Dual LAN Speed Support 10 100 Mbps Ethernet auto detected Server Client Dual Modes EX 9132C 2RS485 converter device can be configured as network server or network client In the client mode it can be inst...

Страница 9: ... Built in 1 5KV Magnetic Isolation Serial Port No of Ports RS 485 422 1 Port and RS 232 422 485 Auto Detect 1 Port Port Type Terminal Block 4pin RS485 422 1 and 7pin RS 232 422 485 1 Speed 300 bps 115 2K bps Parity None Odd Even Mark Space Data Bit 5 6 7 8 Stop Bit 1 2 Port 1 RS 485 Signals Data Data Surge Over Current Protection RS 422 Signals Rx Rx Tx Tx Surge Over Current Protect Built in RS422...

Страница 10: ...tion Virtual Support Windows 2000 2003 XP Vista 7 Firmware On line Updated Via Ethernet Power DC 9 24 V 500mA LED Lamp PORT1 Red PORT2 Green DI DO Red Blink during data input and output LAN Red for 10 Mbps Green for 100 Mbps SYS Red Blink Environment Operating Temperature 0 70 Storage Temperature 10 80 Dimensions 115 90 27 mm W D H WEIGHT 140 gm RoHS Compliant with RoHS Regulatory Approvals FCC CE...

Страница 11: ...10 2 2 EX 9132C 2RS485 Description Installation Product Panel Views Top Side DC In Power Outlet Ethernet LAN Port Serial I O Port RS 485 422 Serial I O Port RS 232 485 RS 422 LED Indicators Reset Button ...

Страница 12: ...RS485 D I O can transform the status of sensor into the TCP IP package data and send out by Ethernet Data Stream The EX 9132C 2RS485 must indicate the IP address and COM Port or activate the indicated Digital output Remote WinSock must indicate the EX 9132C 2RS485 Connect the data wires between the EX 9132C 2RS485 and the RS232 RS 485 RS 422 device Follow the parameter setup procedures to configur...

Страница 13: ... connector for network is the usual RJ45 Simply connect it to your network switch or Hub When the connection is made the LAN LED indicator will light up When data traffic occurs on the network red PORT LED indicator will blink during data transferring and receiving Reset Button If by any chance you forget the setup password or have incorrect settings making TCP IP converter inoperable First turn o...

Страница 14: ...2 Green Port2 data transmitting indicator When data are sending to the network the LED will blink DI DO Red Data input output indicator When data are input output by the network the LED will blink SYS Green It is a device statues indicator When EX 9132C 2RS485 is operated in normal statues the LED will blink once per second ...

Страница 15: ...14 Wiring Architecture RS 232 Wiring Architecture RS 422 RS 485 Wiring Architecture ...

Страница 16: ... indicators are as shown in above diagram the converter is installed correctly You can use the Setup Tool EXBrowser exe to setup the IP Address To proceed the advanced parameter setup please use a web browser IE or Netscape to continue the detailed settings ...

Страница 17: ...s section in Chapter3 Web Console Configuration The following topics are covered in this chapter Device Management Utility EXBrowser View EXBrowser Modify IP EXBrowser Modify MAC Device Management Utility Note EXBrowser also can use on EX 9132C 2RS485 On PC we provide a Device Management Utility named EXBrowser exe which is an executable program in Windows 32 bit environments EXBrowser setup tool ...

Страница 18: ...nverters Otherwise the EXBrowser exe can not detect the converter Due to the nature of broadcast UDP packets EXBrowser has following characteristics Broadcast packets are not limited by subnet Even if the IP address of the converters and the computer running EXBrowser that do not belong to the same subnet it still works fine Broadcast packets can not pass routers EXBrowser can only be used to moni...

Страница 19: ... send another query to get updated information see Figure 3 2 Note Always run the Refresh after any data change Figure 3 2 File Exit Alt F4 Exit from the program see Figure 3 3 Figure 3 3 EXBrowser Modify IP Modify IP Dialog Frame To click the device on the existing devices list in the EXBrowser table and then the function bar will be enable To press second icon of Modify IP on function bar and a ...

Страница 20: ...rk devices When you press Confirm button the IP address will be refreshed in 2 3 seconds Figure 3 5 After click Confirm button and then Input Password request will be pop up on screen see Figure 3 5 Please simply press Confirm button and the new device s IP will be changed and save in table if you changed it Figure 3 6 ...

Страница 21: ...To press Third icon of Modify MAC on function bar and a dialog frame table will be shown see Figure 3 7 Figure 3 7 Input Password Dialog Frame After click Confirm button and then Input Password request will be pop up on screen see Figure 3 8 Please simply press Confirm button and the new device s MAC will be changed and save in table if you changed it Figure 3 8 ...

Страница 22: ...no special software will be required Popular Browsers such as IE or Netscape can easily do the setup process In the browser URL field set the IP address of device directly to enter the Login Setting page please follow the steps below Open your browser This chapter will use IE as an example In the browser URL field type the IP address of the converter directly and press ENTER The IP address is what...

Страница 23: ...ay Hour Minute Second format This information can be useful in identifying the reliability of system Firmware version Converter firmware is identified by date code This information will be required looking for technical support Serial number It is a product serial number code in the converter device and has been provided by factory ...

Страница 24: ...he power and then use any point tip to push Reset button and hold it to turn on the power at the same time for 5 seconds The password will be reset to the factory default as empty Converter device uses the same password protection mechanism commonly used in Windows NT or UNIX If there are more than 3 consecutive failures in password check during login the login function will be disabled for 15 min...

Страница 25: ...rrect password in the Password field and click the Confirm button in the Login Setting page then the Parameter Setting page will be shown see Figure 3 10 Note If you forget the password or can t login successfully please contact the manufacturer directly Figure 3 10 ...

Страница 26: ...ver automatically Gateway address Gateway or Router IP address Gateway is a device which connects local network to external network If you need to communicate with other networks or your device owns a real IP address on the internet please inquire of them that information and type it correctly If there s no gateway on the network just leave it as 0 0 0 0 If DHCP client mode is enabled and there s ...

Страница 27: ...may be empty or up to 15 characters long Serial I O Port 1 RS 485 422 This converter device model provides one serial port as RS 485 422 interface for connecting the extension serial device Local Port Socket Mode Remote IP Port This converter devoice provides one socket connections port Port number A socket port assigned for the serial port It s a 16 bit numbers ranging from 1 to 65535 Because the...

Страница 28: ...Even Odd Space Mark Data Bits 5 6 7 8 Stop Bit 1 or 2 Force off line time It is for setting the off line time period of device will be taken when there is no date input The parameter can be from 0 to 99 and the time unit is Minute Packet Collect Time It is for setting a packet collecting period of the device serial port s Tx and Rx The parameter can be from 0 to 999 and the time unit is mSec Seria...

Страница 29: ...ectionless Remote IP address The server IP address and socket port would be connected in TCP Client and UDP Client mode for a certain serial port Remote socket port The server socket port would be connected in TCP Server TCP Client and UDP Client mode for a certain serial port Interface of serial I O It provides an Auto Detect function and just depends on the connected serial device s interface as...

Страница 30: ... be from 0 to 999 and the time unit is mSec Interface of serial I O RS 232 TxD RxD for data stream no flow control RS 232 RTS CTS TxD RxD for data stream RTS CTS for flow control RS 485 Half duplex Half duplex RS 485 interface RTS for driver enable disable RS 422 Full duplex Full duplex RS 422 interface ...

Страница 31: ...seconds to complete the whole process and a new login page will be presented see Figure 5 1 Figure 5 3 You can re login and check if all parameters have been correctly saved If everything is ok you can close the browser now Note If the domain of the converter is different from that of the computer running the browser the login page won t appear unless the converter s Gateway Address has been corre...

Страница 32: ...the converter inoperable there are two ways to reset the setting and the following procedures can be used to reset all settings to factory default A 1 Please turn on the power and then use any point tip to push Reset button for 5 seconds The password will be reset to the factory default as empty ...

Страница 33: ...dows 95 98 ME XP 2000 Vista 7 The Hyper Terminal utility should be installed on your PC see Figure 6 1 It can be found in your Windows installation CD The wiring architecture is similar to RS 232 Wiring in chapter 3 and the Serial Device is replaced by the PC s COM 1 The same PC also plays the roll of the Remote Host The following topics are covered in this chapter Hyper Terminal for TCP IP WinSoc...

Страница 34: ...33 Hyper Terminal for TCP IP WinSock Initiate a Hyper Terminal from the Start Menu in Windows see Figure 6 1 give a terminal name choose an icon and press OK button see Figure 6 2 Figure 6 1 ...

Страница 35: ...34 Figure 6 2 Select TCP IP Winsock option at the Connect using field see Figure 6 3 ...

Страница 36: ... Figure 6 4 appears Enter the converter s IP address e g 192 168 123 10 at the Host address field and the Socket port number set for the Serial Port 1 at the Port number field e g 4660 The Socket type of the Serial Port 1 should be TCP Server ...

Страница 37: ...36 Figure 6 4 After OK button is pressed Figure 6 5 appears If the Hyper Terminal connects with the converter successfully the time clock at the left lower corner Connected hh mm ss will start counting ...

Страница 38: ...37 Figure 6 5 ...

Страница 39: ... Initiate another Hyper Terminal as a COM Port Terminal in Figure 6 3 select COM 1 or other COM port instead of TCP IP Winsock Set the COM port Properties to be the same as those set for the Serial Port 1 of the converter Figure 6 3 ...

Страница 40: ...e COM Port Terminal and check if the texts are also displayed on the TCP IP Winsock Terminal Alternatively check if the characters typed on the TCP IP Winsock Terminal are also displayed on the COM Port Terminal If yes then all settings are correct and the converter can operate properly ...

Страница 41: ... if the power is properly plugged to the converter if the network cable is properly connected between the converter and the Hub Please refer to the Hardware Installation steps in Chapter 3 Q Why can t I use IE to setup the converter A Please check if the network domain of your PC is the same as that of the converter ...

Страница 42: ...ts and Cable Wiring DC In Jack RJ 45 Pin Assignment RS 232 Pin Assignment The pin assignment scheme for a Terminal Block is given below 7pin RS 232 422 485 1 PIN 1 GND PIN 2 RXD PIN 3 TXD RS 232 Wiring Diagram Serial Device EX 9132C 2RS485 ...

Страница 43: ...ignment scheme for a 4 pin RS 422 of 7 pin Terminal Block RS 232 422 485 is given below PIN 1 R PIN 2 R PIN 3 T PIN 4 T RS 422 Wiring Diagram Serial Device EX 9132C 2RS485 R 3 T R 4 T T 1 R T 2 R RS 485 Wiring Diagram Serial Device EX 9132C 2RS485 D D D D 1 2 3 4 ...

Отзывы: