Страница 1: ...EDFA 1550nm High Power PON EDFA User s Manual MODEL EDFA1550 Series...

Страница 2: ...5 3 2 5 Laser IN Light 5 3 2 6 Laser OUT Light 5 3 2 7 Status Button 5 3 2 8 Function Switch 5 3 2 8 1 Model 6 3 2 8 2 Output Power 6 3 2 8 3 Bias Current 6 3 2 8 4 Laser Temp 6 3 2 8 5 Cooling or hea...

Страница 3: ...remote management at any time 1 1 4 Standard RS232 and RS485 Port 1 1 5 Adopting JDSU Bookham and Fitel laser 1 1 6 LCD displays the parameters functions and trouble alarm 1 1 7 Switch power supply c...

Страница 4: ...34 35 36 Output Power dBm 25 26 27 28 29 30 31 32 33 34 35 36 Output Power mW 320 400 500 640 800 1000 1280 160 0 2000 2560 320 0 400 0 Input Power dBm 3 10 Wavelength nm 1530 1565 Output Sability dB...

Страница 5: ...uts dBm 26 400 4 18 5 8 15 0 27 500 4 19 5 8 16 0 28 630 4 20 5 8 17 0 29 800 4 21 5 8 18 0 30 1000 8 19 0 16 15 5 31 1250 8 20 0 16 16 5 32 1600 8 21 0 16 17 5 33 2000 8 22 0 16 18 5 34 2500 16 19 5...

Страница 6: ...chine begin to work If the light is still red and the screen shows READY KEY OFF this means the power connected but no optical input 3 2 2 CATV In The optical input 3 2 3 Out The Optical Output 3 2 4...

Страница 7: ...t of pump laser If the value comes out of the set value the machine will shine 3 2 8 4 Laser Temp TEMP The laser works between 20 and 30 if the tested value comes out of this range the machine will wa...

Страница 8: ...3 4 Power Switch 3 3 5 Power Socket AC220V or DC 48V power input 4 Notes 1 The main component of the amplifier laser is sensitive to the static electricity so please keep the amplifier away from the...

Страница 9: ...ne 6 Please don t insert the connectors when the power is on 7 Please don t test the EDFA more than 5 times 8 Big power may damage the output port so it is advised to split to more than 2 outputs 9 In...

Страница 10: ...ig loss in the test pigtail 4 There is dust in the connectors 5 The wavelength of the transmitter is big different from 1550nm will make the output value down Solution Use absolute alcohol to wash the...

Страница 11: ...nd troubles should be offered 3 Please pack the unit in its original container If the original container is no longer available please pack the unit in at least 3 inches of shock absorbing material NO...