Curtiss-Wright | Tritex II DC Rev. J PN49220 2/8/2016
50
actuators there is no removable cover. The battery is mounted remotely
and wired through the power connector. The replacement battery only is
Exlar P/N 50748. Observe battery polarity when installing replacement
battery in clips.
Important:
If the battery is removed with both Motor and Logic power
also removed, leave all power
off
and do
not
reconnect the battery for
4 minutes
. Once all power is removed from the battery backed logic it
must be allowed enough time to completely bleed down before
restarting. Once power is re-applied the home position must be
reestablished. For the 60 mm actuator the Motor, Logic and battery
connections are all made through the power connector. This means any
time the power connector is removed from the actuator it should not be
reinstalled for 4 minutes.
Replacement battery assembly for 75 mm and 90 mm
actuators is Exlar PN 42712. Replacement battery for use
on remote battery assembly is Exlar P/N 50748.
Replacement with any other battery will violate UL
and CSA certification.
Travel limitations.
The counter has a range of +/- 4096 motor revolutions; therefore the
actuator must operate within this range and if the actuator is moved
beyond this limit a home position must be re-established.
Speed limitations: When power is off and the counter is under battery
backup, the maximum rpm the counter can track is 2100 rpm.
Ethernet Options, EIP, TCP or ProfiNet
The Ethernet Option provides an Ethernet rated M12 connector for
connection to the Network at the rear of the actuator.
An IP 67 4-pole M12 D coded connector is used, this type of connector
must only be used with two pair cables. When the Ethernet connection is
made via an Ethernet switch or hub, a straight though cable set must be
used. If there is a single node connection direct from the Ethernet
PC/PLC to the Tritex then a crossover cable may be required. Some PC
Ethernet cards have capability to detect a crossover connection. See
Expert Software section for setup of Tritex Ethernet parameters.
WARNING
Содержание Tritex II DC Series
Страница 8: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 8...
Страница 9: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 9...
Страница 10: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 10 EU Declaration of Conformity for CE Mark...
Страница 19: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 19 Dimensions...
Страница 20: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 20...
Страница 21: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 21...
Страница 22: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 22...
Страница 23: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 23...
Страница 53: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 53 Cable Shield Grounding Example...
Страница 62: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 62 ACCESSORIES Cables TTIOC xxx I O Cable...
Страница 63: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 63 TTIPC xxx Power Cable...
Страница 64: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 64 TTICO xxx Communications Cable...