Connecting multiple Tritex actuators to a Modbus Master Host
Important considerations:
Always use 3 conductors, RS485 +, RS485
– and Reference.
A twisted pair for 485+ and 485- is preferred.
RS485 is a “multi-drop” network as opposed to a “star”, therefore
keep the drop (stub) to each actuator as short as possible. When
using the 8 mm connector use a T connector, such as the Exlar
PN TT458SP.
A termination resistor is not usually required.
IA4 Option board connections
4-20 mA Isolated I/O, IA4 Option
The IA4 option board replaces the standard I/O board and provides
one 4-20 mA isolated analog input and one 4-20 mA isolated analog
output; these I/O circuits are isolated from each other as well as all other
actuator I/O, grounds and commons. The IA4 option also includes four
isolated digital inputs and three isolated digital outputs; this is a reduction
from the eight inputs and four outputs available on the standard I/O
board.
The 4-20 mA input is a two wire circuit. A small amount of power from
4-20 mA signal is used to generate the internal power supplies needed
for the isolation of the input section. This allows the input to float with the
Transmitter or loop power supply without inference from the other
Actuator grounds or commons. The power supply starts up when the
input reaches 3mA. When the 4-20 mA loop is unpowered, the software
reads an off-scale high value that should be configured to indicate a
“Loss of Signal” condition.
Modbus Master
PC, HMI, PLC etc
485+ 485- Ref
Tritex 1
Tritex 2
Tritex (n)
(32 max)
Содержание Tritex II DC Series
Страница 8: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 8...
Страница 9: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 9...
Страница 10: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 10 EU Declaration of Conformity for CE Mark...
Страница 19: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 19 Dimensions...
Страница 20: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 20...
Страница 21: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 21...
Страница 22: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 22...
Страница 23: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 23...
Страница 53: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 53 Cable Shield Grounding Example...
Страница 62: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 62 ACCESSORIES Cables TTIOC xxx I O Cable...
Страница 63: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 63 TTIPC xxx Power Cable...
Страница 64: ...Curtiss Wright Tritex II DC Rev J PN49220 2 8 2016 64 TTICO xxx Communications Cable...