EXFO PPM-350C Скачать руководство пользователя страница 27

PPM-350C

21

Recalling Data

According to the storage configuration you have set using the Handheld Data 
Transfer application, you can recall data you have previously stored. 
You can recall files according to the following modes, depending on how your unit 
was set:

OLT and ONT IDs, with different locations.

Job, where the OLT and ONT are grouped in different locations.

To recall data in OLT mode:
1.

Press and hold down 

 for a few seconds to access the data recall menu.

2.

Press 

 to access the available OLT 

values. The OLT name is displayed next 
to the 

Loc.

 indicator.

3.

Press 

 to select the OLT and switch to the ONT selection. 

4.

Press 

 to access the available ONT.

5.

Press 

 to select the ONT or 

 to exit the recall 

mode.

The data is recalled. Press 

 to go through the data 

with the same OLT and ONT values.

To recall data in Job mode:
1.

Press and hold down 

 for a few seconds to access the data recall menu.

2.

Press 

 to access the available Job ID values.

3.

Press 

 to select the job or 

 to exit the recall 

mode. 

The data is recalled. Press 

 to go through the data 

with the same Job ID values.

Store/

Select

OLT ID 

number

OLT name

Next

Store/

Select

Next

Store/

Select

Next

Store/

Select

Next

Store/

Select

Next

Содержание PPM-350C

Страница 1: ...User Guide PON Power Meter PPM 350C...

Страница 2: ...ise under any patent rights of EXFO EXFO s Commerce And Government Entities CAGE code under the North Atlantic Treaty Organization NATO is 0L8C3 The information contained in this publication is subjec...

Страница 3: ...Electrical Offsets 12 4 Configuring Thresholds Correction Factors Wavelength List and Storage Details 13 5 Working in FTTx Mode 14 Selecting a Threshold Set 14 Testing in Pass Fail Mode or in Normal M...

Страница 4: ...Contents iv 11 Warranty 35 General Information 35 Liability 35 Exclusions 36 Certification 36 Service and Repairs 37 EXFO Service Centers Worldwide 38 A Technical Specifications 39...

Страница 5: ...forts to ensure compliance to the applicable standards The limits set by these standards are designed to provide reasonable protection against harmful interference when the equipment is operated in a...

Страница 6: ...me Model No PON Power Meter PPM 350B PPM 350C Standard s to which Conformity is declared EN 61010 1 2001 Edition 2 0 Safety requirements for electrical equipment for measurement control and laboratory...

Страница 7: ...y testing voice video and data Measures each signal independently Optical Network Terminal ONT 1310 nm central office CO 1490 nm and 1550 nm Measures optical power of any type of signal Continuous for...

Страница 8: ...can manage data directly on the unit storing recalling deleting The Handheld Data Transfer provided on your CD enables you to create new threshold sets and correction factors define your list of favor...

Страница 9: ...Meter operates with the following power sources AC adapter connected to standard power outlet indoor use only AA alkaline batteries automatically take over if you unplug the AC adapter The icon also i...

Страница 10: ...ve optical networks at ONT drop terminal fiber distribution hub or CO This mode allows you to measure two or three wavelengths simultaneously depending on the configuration of the unit OPM mode You ca...

Страница 11: ...nd and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Do not proceed unless you understand and meet the re...

Страница 12: ...n provided by this unit WARNING Do not install or terminate fibers while a laser source is active Never look directly into a live fiber and ensure that your eyes are protected at all times IMPORTANT W...

Страница 13: ...cted to one of the ports of the PPM 350C light may come out from the other port even if the protective cap is on Do not consider that the protective cap is sufficient protection in such high power las...

Страница 14: ...n the unit on Press The unit displays EXFO for a few seconds and vertical bars move at the top of the display indicating the initialization is in progress You may use your unit immediately under norma...

Страница 15: ...Controls auto off Exits special modes HOLD Turns unit off PRESS Accesses the storage mode in selection mode selects the value HOLD Accesses the data recall mode in Recall mode accesses the delete ite...

Страница 16: ...ors with angled APC or non angled UPC polishing A green border around the baseplate indicates that it is for APC type connectors To install an EUI connector adapter onto the EUI baseplate 1 Hold the E...

Страница 17: ...n place thus ensuring adequate contact If your connector features a screwsleeve tighten the connector enough to firmly maintain the fiber in place Do not overtighten as this will damage the fiber and...

Страница 18: ...r when measuring very low power values Note Factory defined values will be reinstated when you turn the unit off To perform an offset nulling Hold down and a few seconds The unit displays NULL and ver...

Страница 19: ...be a good idea to send your PON Power Meter for recalibration see Recalibrating the Unit on page 27 This will ensure the results remain accurate A wavelength list consisting of 1310 nm 1490 nm and 15...

Страница 20: ...set will be used to determine the Pass Warning Fail status Your unit contains up to 10 threshold sets but only one set can be selected at a time Depending on the model of the unit a threshold set com...

Страница 21: ...velength that has not been deactivated 3b Press or to switch to the next wavelength Note If a wavelength has been deactivated via the Handheld Data Transfer refer to the Handheld Data Transfer online...

Страница 22: ...f Note If the result is greater than the Pass threshold the word Fail and the LED will flash If the result is lower than the Fail threshold the unit will only display Fail and the LED will not flash A...

Страница 23: ...not press Ensure that the desired threshold set is selected see Selecting a Threshold Set on page 14 Results are now available Test at the premises Test jumper ONT port Test jumper OLT video port Drop...

Страница 24: ...e wavelength When you use reference your unit displays the loss created by the fiber under test only since it subtracts a reference value from the measured power To perform loss measurements 1 Clean y...

Страница 25: ...wing modes selected by HHDT OLT and ONT IDs with different locations Job where the OLT and ONT are grouped with different locations To store data in OLT mode 1 Press to access the data storage menu Th...

Страница 26: ...to enter further information 2 Press to access the available Job ID values 3 Press to select the job and access the available Loc IDs 4 Press to select the location or to exit the storage mode The dat...

Страница 27: ...lable OLT values The OLT name is displayed next to the Loc indicator 3 Press to select the OLT and switch to the ONT selection 4 Press to access the available ONT 5 Press to select the ONT or to exit...

Страница 28: ...ter This way you can free memory space perform better analyses on your data and create reports To transfer data to a computer 1 Using a USB cable connect your unit to an available USB port of the comp...

Страница 29: ...ber 1 Connect the fiber under test to the VFL port see Cleaning and Connecting Optical Fibers on page 11 2 Press and hold down for a few seconds to switch between ON CW continuous signal and ON 1HZ bl...

Страница 30: ...and dry area Keep the unit out of direct sunlight Avoid high humidity or significant temperature fluctuations Avoid unnecessary shocks and vibrations If any liquids are spilled on or into the unit tur...

Страница 31: ...5 mm cleaning tip with one drop of isopropyl alcohol alcohol may leave traces if used abundantly 3 Slowly insert the cleaning tip into the EUI adapter until it comes out on the other side a slow clock...

Страница 32: ...face with a portable fiber optic microscope for example EXFO s FOMS or fiber inspection probe for example EXFO s FIP 7 Put the EUI back onto the instrument push and turn clockwise 8 Throw out cleaning...

Страница 33: ...sly agreed upon with the customer Validity of specifications depends on operating conditions For example the calibration validity period can be longer or shorter depending on the intensity of use envi...

Страница 34: ...n factors wavelength lists and storage information If a problem is detected error code 9 10 or 12 will be displayed If you turn the unit off without correcting the problem the error code will be displ...

Страница 35: ...the display indicating the verification is in progress The three LEDs will light up briefly in the following order green yellow red Once LEDs are turned off all the screen segments will be displayed a...

Страница 36: ...Pressing the button does not activate Pass Fail mode Unit is currently nulling offsets verifying thresholds or verifying LEDs and LCD Let the unit complete the operation If the unit was verifying LED...

Страница 37: ...lengths and some of the LEDs are off At least one signal is deactivated see Selecting a Threshold Set on page 14 Reactivate the signal see Configuring Thresholds Correction Factors Wavelength List and...

Страница 38: ...17 No signal is activated for the selected threshold The error is displayed again if you try to activate the threshold You must enter the threshold selection mode to select another threshold This err...

Страница 39: ...To accelerate the process please have information such as the name and the serial number see the product identification label as well as a description of your problem close at hand You may also be req...

Страница 40: ...sportation damage can occur from improper handling The following steps are recommended to minimize the possibility of damage Pack the unit in its original packing material when shipping Avoid high hum...

Страница 41: ...ITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL EXFO BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES Liability EXFO shall not be liable for damages resulting from the use of the p...

Страница 42: ...products are not covered by this warranty This warranty excludes failure resulting from improper use or installation normal wear and tear accident abuse neglect fire water lightning or other acts of...

Страница 43: ...hich it was observed 5 Return the equipment prepaid to the address given to you by support personnel Be sure to write the RMA number on the shipping slip EXFO will refuse and return any package that d...

Страница 44: ...3 5498 Fax 1 418 683 9224 support exfo com EXFO Europe Service Center Omega Enterprise Park Electron Way Chandlers Ford Hampshire S053 4SE ENGLAND Tel 44 2380 246810 Fax 44 2380 246801 support europe...

Страница 45: ...nm 1310 nm 1260 to 1360 1260 to 1360 1490 nm 1480 to 1500 1480 to 1500 1550 nm 1539 to 1565 1539 to 1565 Power uncertainty b c d dB 0 5 0 5 Calibrated wavelengths nm 1310 1490 1550 1310 1490 Threshol...

Страница 46: ...dous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 SJ T11363 2006 Part Name Toxic or hazardous Substances and Ele...

Страница 47: ...01 EXFO ASIA PACIFIC 100 Beach Road 22 01 03 Shaw Tower SINGAPORE 189702 Tel 65 6333 8241 Fax 65 6333 8242 EXFO CHINA Beijing Global Trade Center Tower C Room 1207 36 North Third Ring Road East Dongch...

Отзывы: