Test Functions
Power Blazer
553
Client Offset
Client Offset
Note:
Available with OTN BERT test application with
1GbE
client and
Pattern
client with
ODUflex
multiplexing.
From the
Test
menu, tap
Functions
, and the
Client Offset
tab.
TX Frequency
Note:
TX Frequency is not available in
Through
/
Through
Intrusive
topology.
Frequency (GHz)
indicates the frequency (nominal fre
port frequency client frequency offset) used for transmission.
Offset (ppm)
check box, when selected (cleared by default), allows
setting the client frequency offset that will be generated. Use the “+” or
“-” button to respectively increment or decrement the client frequency
offset value based on the defined
Increment/Decrement Size
, or
directly type the frequency offset value in the field.
Increment/Decrement Size (ppm)
allows setting the
increment/decrement value (from 0.1 to either 115) that will be used
when changing the frequency offset using the “+” or “-” button.
Client
Nominal Frequency
Offset
a
a.
The Client frequency offset range is guaranteed for a clock source signal at 0 ppm
offset. In the event that the clock source signal already has an offset, the output signal
may exhibit an offset larger than the range specified. For example, if the clock source
signal has an offset of +20 ppm (configured on the Signal interface), the Client
frequency offset could be up to 135 ppm (115 ppm + 20 ppm).
1GbE
1250000000 bps
± 115 ppm
Pattern in ODUflex Nominal bit rate configured (refer to
Nominal Bit Rate
on page 306).
± 115 ppm
b
b.
The Client offset function does not allow the generation of a signal with a rate above
100 % of the TX rate. For example, if the TX Rate is set to 100 %, the allowed offset
range will be -115 ppm to 0 ppm.
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...