Test Functions
548
88000 Series
40/100G/400G Advanced - Lanes Mapping & Skew
Reset/Manual Skew
Allows the selection of a relative delay in bit time that will be introduced for
each PCS/Logical lane. Not available with 100 GbE client in OTU4.
Reset Skew
sets all TX skew (bit time) values to 0.
Manual Skew
allows setting the skew value for each PCS/Logical lane
manually.
All Lanes
, when selected, applies the change(s) to all PCS/Logical
Lane at once.
Skew Inc/Dec Size (bits)
allows setting the increment/decrement
value that will be used when changing the TX Skew (bits) values
using the “+” and “-” buttons. Range is from
0
to
10550
for 400G,
0
to
2047
for 100G/OTU4 and
0
to
4095
for
40G/OTU3/OTU3e1/OTU3e2.
PCS/Logical Lane
indicates the PCS/Logical Lane numbers and
All
which represents the value for all PCS/Logical Lane when the
All
Lanes
check box is selected.
Skew (bits)
allows setting the skew value for each lane. Enter
directly the skew value in the field or use the “+” and “-” buttons to
respectively increment or decrement the skew value using the
defined
Skew Inc/Dec Size
value. Tapping and holding the “+” or
“-” button allows reaching the desired value faster using the
defined
Skew Inc/Dec Size
value. Range is from
0
to
10550
for
400G,
0
to
2047
for 100G/OTU4 and
0
to
4095
for
40G/OTU3/OTU3e1/OTU3e2.
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...