Test Results
402
88000 Series
Alarms/Errors Overview
TCM (SONET/SDH)
Note:
TCM is displayed for rates up to OC-192/STM-64 under the STS-x/AU-x or
VT/TU alarms/errors group when TCM is enabled.
Alarms
TC-UNEQ-P
/
HPTC-UNEQ (
Unequipped)
RX/TX
: An all “0”s pattern is received/generated in the higher order
path signal label byte (C2), the TCM byte (N1) and the path trace byte
(J1), and a valid BIP-8 bytes (B3).
TC-UNEQ-V
/
LPTC-UNEQ
(Unequipped)
(LPTC - Unequipped)
RX/TX
: An all “0”s pattern is received/generated in the lower order path
signal label (bit 5, 6, 7 of byte V5), the TCM byte (Z6/N2) and the path
trace byte (J2), and a valid BIP-2 (bits 1, 2 of V5 byte).
TC-LTC-P / TC-LTC-V
/
HPTC-LTC / LPTC-LTC
(Loss of Tandem
Connection)
RX/TX
: A wrong FAS multiframe is received/generated.
TC-IAIS-P
/
HPTC-IAIS
(Incoming Alarm Indication Signal)
RX/TX
: Bits 1 through 4 of the N1 byte are set to “1110”.
TC-IAIS-V
/
LPTC-IAIS
(Incoming Alarm Indication Signal)
RX
/
TX
: Bit 4 of the Z6/N2 byte is set to “1”.
TC-ODI-P / TC-ODI-V
/
HPTC-ODI / LPTC-ODI
(Outgoing Defect
Indication)
RX/TX
:
SONET: Bit 7 of the N1/Z6 byte frame 74 is set to “1”.
SDH: Bit 7 of the N1/N2 byte multiframe 74 is set to “1”.
Содержание Power Blazer 88000 Series
Страница 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Страница 12: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 38: ......
Страница 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Страница 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Страница 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Страница 550: ......
Страница 670: ......
Страница 674: ......
Страница 686: ......
Страница 707: ...Glossary Power Blazer 695 10G Ethernet Client The following figure presents a typical network application ...
Страница 721: ...Glossary Power Blazer 709 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s ...
Страница 765: ...Glossary Power Blazer 753 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values ...