Test Setup - Test Configurator, Timer, and System
MaxTester
151
Services - Global
Services - Global
From the
Test
menu, tap
Setup
,
Test Configurator
, tap on the services
block, the
Global
tab, and on the
General
button.
General Button
The following parameters are displayed and configurable per service.
Check boxes:
The first check box (top-left) allows enabling sequentially
service(s) within the limit of the link capacity when the
Service
Performance Test
is enabled or enabling all services when the
Service Performance Test
is disabled.
The check boxes next to the service numbers allow enabling each
service individually.
When the
Service Performance Test
is enabled, up to 10 services
can be enabled one after the other, as long as the
Total TX Rate
(bandwidth) is not reached (
Committed
). For example, if the first
service is using the full bandwidth available, then no other service
can be enabled. If the first enabled service uses half bandwidth,
then at least another service can be enabled using up to half
bandwidth. Thus, to enable a second service, first set the CIR value
within the non-used bandwidth (
Available
), then enable it.
When the
Service Performance Test
is disabled, up to 10 services
can be enabled one after the other; the total TX rate is not limited.
Service Name
indicates the name of each service. Tap on the
Service
Name
button to modify the name of each service. See
for more information.
Direction
, available with
Dual Test Set
or
Dual Port
topology,
indicates respectively results for local (
L
) and remote (
R
) directions, or
for both port directions.
Содержание MAX-800 Series
Страница 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Страница 16: ......
Страница 18: ......
Страница 26: ......
Страница 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Страница 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Страница 62: ......
Страница 208: ......
Страница 414: ......
Страница 426: ......
Страница 446: ...Glossary 438 MAX 800 Series Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...
Страница 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Страница 476: ......
Страница 492: ...Index 484 MAX 800 Series Z Z0 344 Z1 346 Z2 349 Z3 353 Z4 353 Z5 353 Z6 355 Z7 356 Zero Code Suppression 169...
Страница 494: ...0 5 1 5 48 5 0 176 W d y K y K D...