Test Setup - Test Configurator, Timer, and System
142
MAX-800 Series
RFC 2544 - Subtests
RFC 2544 - Subtests
From the
Test
menu, tap
Setup
,
Test Configurator
, tap on the RFC 2544
block. and on the
Subtests
tab.
Allows the configuration of each enabled subtest.
Throughput
The objective of this test is to find the throughput of the device under test
for which there is no frame loss. Starting at the specified maximum rate
(
Max. Rate
), the rate converges towards the highest throughput without
frame loss. The search is done with a halving/doubling method until a final
value is reached. The test performs the number of trials defined (
Trials
).
The throughput measurement is validated by the number of times
specified (
Validations
) for the predefined duration
(Trial Duration)
. The
Accuracy
and
Acceptable Errors
specify how precise the result must be.
The test is performed for each defined frame size.
Содержание MAX-800 Series
Страница 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Страница 16: ......
Страница 18: ......
Страница 26: ......
Страница 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Страница 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Страница 62: ......
Страница 208: ......
Страница 414: ......
Страница 426: ......
Страница 446: ...Glossary 438 MAX 800 Series Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...
Страница 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Страница 476: ......
Страница 492: ...Index 484 MAX 800 Series Z Z0 344 Z1 346 Z2 349 Z3 353 Z4 353 Z5 353 Z6 355 Z7 356 Zero Code Suppression 169...
Страница 494: ...0 5 1 5 48 5 0 176 W d y K y K D...