Setting Up DSL/IP Tests
54
MAX-630G
Test Configuration
Thresholds
The
Thresholds
tab allows you to define DSL
parameter criteria. For
D/S
(downstream) and
U/S
(upstream) data rates, there are
OK
and
Min
(minimum) bit rates defined to indicate unacceptable,
marginal, and acceptable rates.
D/S
and
U/S OK bit rate
:
for ADSL - value limited to D/S 30 Mbit/s,
U/S 2 Mbit/s.
for VDSL - D/S to 100 Mbit/s, U/S to 50 Mbit/s.
for G.fast - D/S and U/S maximum value set to
1000 Mbit/s.
for VDSL2-35b - D/S can be 350 Mbit/s, U/S is 50 Mbit/s.
D/S
and
U/S Min SNR margin
- values range from 0 to 63.5 dB. Default
is 5 dB.
D/S
and
U/S Max Attenuation
- values range from 0 to 96 dB. Default is
10 dB.
Sync Loss Counter
is the number of times the unit lost
synchronization.
Bonding Criteria
allows you to select either
Single Line
/
Both Lines
Connected & Bonded
to check the pass/fail criteria of the DSL lines in
bonding mode.
To set threshold values:
1.
Press the up/down arrows to select the desired parameter.
2.
Press the left/right arrow keys to view and select the options.
OR
3.
Press
on a value to open the alphanumeric editor screen and use
the navigation keys to scroll through.
Содержание MAX-630G
Страница 1: ...User Guide G fast VDSL2 ADSL2 Multi play Test Set MaxTester 630G ...
Страница 10: ...Introducing the MAX 630G 4 MAX 630G Using the MaxTester Front Power LED Battery LED Speaker Touchscreen ...
Страница 14: ......
Страница 18: ......
Страница 126: ......
Страница 136: ......
Страница 148: ......
Страница 154: ......
Страница 157: ...Index G fast VDSL2 ADSL2 Multi play Test Set 151 liability 144 null and void 143 web browser 56 74 Wi Fi symbol 31 ...