Analyzing Traces with the Bidirectional Analysis Application (Optional)
OTDR
211
Reanalyzing Traces and Regenerating the Bidirectional Measurement
Reanalyzing Traces and Regenerating the
Bidirectional Measurement
You can analyze the A->B and B->A traces and regenerate the
bidirectional measurement at any time. Reanalyzing a trace will:
³
re-create the events table if it was modified.
³
reset the span start to zero and the span end to end-of-fiber, unless you
have saved them (see
Saving the Span-Start and Span-End Information
The table below shows what happens when you start the analysis,
depending on the direction that is currently selected.
Note:
In the case of multiwavelength files, the analysis is performed for the
selected wavelength only.
If you prefer to focus your analysis on a specific fiber span, see
the Alignment of Unidirectional Traces
Current direction
Bidirectional
measurement
A
->
B trace
B
->
A trace
Bidirectional
Regenerated
Reanalyzed
Reanalyzed
A->B
Regenerated
Reanalyzed
Not modified
B->A
Regenerated
Not modified
Reanalyzed