background image



FTBx-88000 Series

Power Blazer and NetBlazer

Getting Results

The 

Summary

 tab is automatically 

displayed once the test is started. 
Select a tab to get additional test 
results.

Alarm/Error Injection

Test control buttons are 
reconfigured according 
to the test application 
and status.

The 

Stop

 button is 

displayed when the 
test is running.

1

Tap the 

Alarms/Errors

 tab.

3

Tap 

Inject

.

Gives more information on this alarms/errors group.

Hides the alarm/error selection.

Status Bar

Additional Status Bar Symbols:

Test Control Buttons

Connection established between two testing units in 

Dual Test Set

 (DTS), 

EXFO|Worx Interop

, or in 

Loop Up

 mode.

Connection not established between two testing units in 

Dual Test Set

 (DTS), 

EXFO|Worx Interop

, or in 

Loop Up

 

mode. 
Remote unit is busy (locked) in 

EXFO|Worx Interop

 operation mode.

LINK

: Port link 

PTP

: 1588 PTP, PTP Frames 

ESMC

: SyncE, ESMC Frames 

Loopback Tool (Only available with 8870/8880)

(BTS)

CPRI, Base Station emulation mode 

(RRH)

CPRI, Remote Radio Head emulation mode 

Start
Stop
TX 

Starts test. Available when the test is not running.
Stops test. Available when the test is running.
Enables traffic generation and starts test. Available with Traffic Gen & Mon and eCPRI BERT. 

Save
Load

Saves, loads, imports, exports, and deletes configuration file(s). Available when the test is not 
running.

Report

Saves, opens, imports, exports, and deletes test report(s). Available when the test is running or 
stopped, but the report generation (save) is only possible when the test is stopped.

Laser

 (on) Indicates that the laser control is on (for at least one lane for parallel interface); the laser button 

has a red border. Tapping this button will turn off the laser (for all lanes for parallel interface). Only 
available with optical ports.

Laser

 (off) Indicates that the laser control is off (for all lanes for parallel interface). Tapping this button will 

activate the laser immediately by emitting an optical laser signal (on all lanes for parallel 
interface). Only available with optical ports.

Reset

Clears results, statistics, and logger content. Available when the test is running. 

Inject

Injects alarms/errors based on settings from the Inject button from the Results - Alarms/Errors tab. 

Discover 
Remote

Discovers and connects to a remote module that loops back the traffic via Smart Loopback or 
Dual Test Set (DTS). 

Lpbk Tool

Loops back the Ethernet frames/packets that are received on the port unused by the main test 
application. Only available with 8870/8880.

More/ 
Less

The More/Less button appears when there is not enough room to display all available test control 
buttons. 

Test

Direction

Pattern Synchronization

Power

Clock

Laser

Remote Control

Inject

Non-default OH

Interface/Signal

Port

Global Indicator

Tap anywhere within the global 
indicator area to view the 
maximized view of these 
indicators. 

The global indicator displays the pass/fail verdict, 
global alarm, timer, and/or test duration. 

2

Tap to select an alarm/error.

4

Select the alarm/error to 
be injected and its 
parameters.

Quick Reference Guide

HIGH-SPEED MULTISERVICE TEST MODULE

© 2020 EXFO Inc. All rights reserved.
Printed in Canada (2020-02)
P/N: 1079326

Version: 9.0.0.1

For more information,

refer to the user guide.

Physical Interfaces 

TX: E1/2M, E3/34M, DS3/45M, STS-1e/STM-0e/52M, E4/140M, STS-3e/STM-1e/155M

RX2: DS3, 2 MHz, 10 MHz

Clock OUT: DS1/1.5M, E1/2M, 2MHz

Ethernet 10/100/1000 Mbit/s electrical

TX and RX: DS1/1.5M, E1/2M

RX2: DS1/1.5M

Clock IN/OUT: DS1/1.5M, E1/2M, 2MHz

E1/2M, E3/34M, DS3/45M, STS-1e/STM-0e/52M, E4/140M, STS-3e/STM-1e/155M, 1PPS, 2 MHz

Clock IN: DS1/1.5M, E1/2M, 2MHz, 10MHz, 1 PPS

DS1/1.5M, E1/2M, 1PPS, 2 MHz, 10  MHz

Clock IN/OUT: DS1/1.5M, E1/2M, 2MHz

External Clock: 
DS1/1.5M, E1/2M, 
2MHz, 1PPS

Reference 

Output

QSFP+:

QSFP28:

QSFP56:

Ethernet 40 Gbit/s 
OTU3e2, OTU3e1, OTU3 
Ethernet 100 Gbit/s 
OTU4 
Ethernet 100 Gbit/s

1. Available on P1 for 88200NGE and on P2 for 8870/8880 

2. Available on 88200NGE

Ethernet 100 Gbit/s 
OTU4 

Ethernet 100 Mbit/s, 1000 Mbit/s, 10 Gbit/s optical 
Ethernet 10/100/1000 Mbit/s electrical (using active copper SFP)

1

Fibre Channel 1X, 2X, 4X, 8X, 10X, 16X

2

CPRI 1.2, 2.4, 3.1, 4.9, 6.1, 9.8, 10.1 Gbit/s
OBSAI 1.5, 3.1, 6.1 Gbit/s 
OC-1/STM-0, OC-3/STM-1, OC-12/STM-4, OC-48/STM-16, OC-192/STM-64 
OTU1, OTU2, OTU1e, OTU2e, OTU1f, OTU2f 

Connect the signal to the corresponding interface on the module. For optical port, insert an EXFO supported 
transceiver into the port’s slot then carefully connect optical fiber cables to the transceiver IN (RX) and OUT (TX) 
ports. 

DS1/1.5M, E1/2M

Clock IN: DS1/1.5M, E1/2M, 2MHz, 1 PPS

Отзывы: