DSn Tabs
216
FTB-8100 Series Transport Blazer
DS0/64K TX
Payload Content
Select the payload content by pressing once or several times on each
timeslot until the desired content appears (or use the Set All buttons).
Choices are
Pattern
,
Idle
, and
Tone
. The default setting is
Pattern
.
³
Pattern
: Uses the selected pattern from the
Pattern TX
on page 335.
³
Idle
: Uses the Idle code byte from the Idle field. Choices are
00
to
FF
.
The selected Idle code applies to all timeslots set to Idle. The default
setting is
7F
.
Binary
: Allows either displaying the Idle code values in binary (when
enabled) or hexadecimal (when disabled). This setting is disabled by
default.
³
Tone
: Allows the selection of a tone for digital milliwatt testing. The
signal output power, when converted to analog, is 0 dBm. Choices are
1000 Hz
and
1004 Hz
. The selected Tone applies to all timeslots set to
Tone. The default setting is
1004 Hz
.
³
Payload Content
:
Allows the selection of the payload content that will
be applied when pressing
Set All
. Choices are
Pattern
,
Idle
and
Tone
.
³
Set All
: Allows to set the payload content of all timeslots to the selected
payload content with its Pattern, Idle, or Tone value.
Note:
The timeslots set to Idle or Tone can be changed from Idle to Tone and vice
versa even when the test is running; the Idle and Tone values can also be
changed.
Содержание FTB-8100 Series
Страница 1: ...User Guide FTB 8100 Series for FTB 200 SONET SDH Application...
Страница 18: ......
Страница 22: ......
Страница 24: ......
Страница 94: ......
Страница 108: ......
Страница 178: ......
Страница 224: ......
Страница 260: ......
Страница 312: ......
Страница 352: ......
Страница 382: ......
Страница 412: ......
Страница 490: ......
Страница 500: ......