Test Results
NetBlazer
369
Performance Monitoring
SEP
(Severely Errored Period) (
G.828
only): A sequence between
3 to 9 consecutive SES. The sequence is terminated by a second which
is not a SES.
SEPI
(Severely Errored Period Intensity) (
G.828
only): Gives the count
of SEP events in available time, divided by the total available time in
seconds.
Far-End
EFS
(Error Free Second): Gives the count of the seconds within which
no error occurred or when a defect is detected on the near-end.
EC
(Error Count) (
G.821
only): Gives the number of bit errors.
EB
(Errored Block) (
G.826
,
G.828
, and
G.829
): Gives the count of
blocks in which one or more bits are in error.
ES
(Errored Second): For
G.826
,
G.828
,
G.829
,
M.2100 ISM
, and
M.2101
: Gives the count of the seconds within which one or more
anomalies (FAS (DSn/PDH), EB, etc.) occurred or at least one defect
occurred.
SES
(Severely Errored Second)
For G.826
,
G.828
,
G.829
and
M.2101
: Gives the number of seconds
within which anomalies (FAS (DSn/PDH), EB, etc.) are
X percent or
at least one defect occurred. X=30 percent for DSn/PDH signals; see
the following table for SONET/SDH signals SES threshold.
OC-1
STS-1e
STM-0
STM-0e
OC-3
STS-3e
STM-1
STM-1e
OC-12
STM-4
OC-48
STM-16
OC-192
STM-64
Path
30%
30%
30%
30%
30%
Line/MS
15%
15%
25%
30%
30%
Section/RS
10%
30%
30%
30%
30%
Содержание FTB-1
Страница 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Страница 12: ......
Страница 20: ......
Страница 22: ......
Страница 52: ......
Страница 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Страница 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Страница 84: ......
Страница 98: ......
Страница 298: ......
Страница 574: ......
Страница 604: ...Glossary 592 FTB 700G 800 Series Acronym List W WAN Wide Area Network WIS WAN Interface Sublayer WWN World Wide Name...
Страница 606: ...Glossary 594 FTB 700G 800 Series 10G Ethernet Client The following figure presents a typical network application...
Страница 619: ...Glossary NetBlazer 607 Ethernet Cables Straight Through Cable 1000 Mbit s Crossover Cable 1000 Mbit s...
Страница 646: ...Glossary 634 FTB 700G 800 Series SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Страница 652: ......
Страница 674: ...0 5 1 5 48 5 0 176 W d y K y K D...