background image

Installation and Operation Manual

                                Economic  PTZ  Dome

Models covered

PTZ220

Version 1

For updates to these instructions visit

www.excelPTZ.com

the

excel

PTZ

range

Содержание PTZ220

Страница 1: ...Installation and Operation Manual Economic PTZ Dome Models covered PTZ220 Version 1 For updates to these instructions visit www excelPTZ com the excelPTZ range...

Страница 2: ...Setting up the Dome Camera 12 RS485 connection Connecting the Keypad or DVR to the Dome 13 Connecting the video out of the dome 15 Setting the PTZ dip switches 17 Setting up a unique address in a dom...

Страница 3: ...bles should be kept way from other high voltage equipment such as mains cables and especially fluorescent lights Using an anti surge protection device is recommended to prevent damage to the domes fro...

Страница 4: ...TZ domes Description of Functions 1 Integrated Multi Protocol Decoder The integrated multifunctional decoder can communicate with 16 different protocols The baud rate can be independently set allowing...

Страница 5: ...rve in the comfort of your own premises Overview introduction to fitting PTZ equipment Generally speaking PTZ Domes requires four things 1 They require a power supply and a cable to supply this power...

Страница 6: ...ease note DVR s tend to require very good video signals to function correctly and passive baluns can loose some signal strength over the 50 meter mark so try to restrict the use of passive baluns to b...

Страница 7: ...ards RS485 is a half duplex data transmission type with characteristic impedance of 120 The maximum load capacity is 32 units domes keyboards and DVRs 2 Transmission distances of RS485 Signals using C...

Страница 8: ...m better reliability so that the domes function as expected A common mistake installer s make is not making sure the 120 resistor is switched ON in the LAST dome Also installers often select the resis...

Страница 9: ...dome in a STAR array is the only practical solution So how do you do this in practice The termination resistors must be connected to the two domes that are farthest away from each other such as domes...

Страница 10: ...ually designed for RS485 but generally works okay if you follow the previous notes on getting the 120ohm resistor setting right as per the previous notes One way that takes the guesswork out of instal...

Страница 11: ...dip switch setting to ON on the SW1 dip switch in the domes Domes 2 3 and 6 are all midway in each spur and do not need the 120ohm resistor and can be left as default The PTZ750 itself has four 120ohm...

Страница 12: ...nt of about 1 25A when the heater is on and you must take this in to consideration when working out maximum cable runs Please note The domes heater doesn t come on until it senses the temperature drop...

Страница 13: ...cable the composite cable and the PTZ400 range domes Power cable requirement Assuming a starting voltage of 24VA C is applied at the PSU end Composite cable Heater OFF Heater ON Maximum run 80mtr 70mt...

Страница 14: ...d provides the RS485 A and RS485 B connections from the keyboard It is this cable that you would extend using 1 pair of conductors from a CAT5 cable To test the dome on your workbench you can obviousl...

Страница 15: ...V W i r e Connect i on Di agr am Red AC24V Bl ack AC24V O r ange RS485 Yel l ow RS485 O r ange RS485 Yel l ow RS485 Bl ack Ter m i nal RS485 Cont r ol Bl ack Ter m i nal RS485 Cont r ol Red Ter m i na...

Страница 16: ...16 24V AC INPUT RS485 A ORANGE RS485 B YELLOW RS485 INPUT ON DVR PSU CAT5 Data cable RG59 Video Cable Power Cable...

Страница 17: ...the keyboard talks to the right dome when you want it to PTZ If you only have the one dome on the site then the default address of 1 is okay and you have no reason to change the dome from this With m...

Страница 18: ...7 8 9 10 Speed D om e Addr ess 1023 O N 1 2 3 4 5 6 7 8 9 10 ID CODE Status Dome Address DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 DIP 9 DIP 10 1 ON OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF...

Страница 19: ...NEON ON OFF OFF OFF OFF ON Santachi OFF ON OFF OFF OFF ON PELCO D ON ON OFF OFF OFF OFF PELCO P 4800 ON OFF PELCO P 9600 OFF OFF ON OFF OFF ON PANASONIC ON OFF ON OFF OFF ON Longcomity OFF ON ON OFF O...

Страница 20: ...Table 2 SW2 is used to set the protocol of communication and the baud rate used by the dome camera DIP 5 and DIP 6 of SW2 are used to select the baud rate of communication and a maximum of 4 differen...

Страница 21: ...rotocol protocol D or P The current camera address each P T device requires a unique address 1 32 The current baud rate To set up the keyboard to the correct settings for this dome do the following TI...

Страница 22: ...me has a test button located alongside the two dip switches If this is pressed the dome will start a self check routine moving the camera in a horizontal and vertical direction This is run continuousl...

Страница 23: ...this dome are taken regarding the weight of the unit and the surface strength to which the unit is connected 2 Description of Unit 2 1 Installation of Indoor Wall Hanging Unit 2 2 Installation of Indo...

Страница 24: ...l and fit the expansion screws c Fasten the support by four nuts and washers onto the wall Figure 10 3 2 Installation of the Ceiling Mount fitting a Select the position of installation on a secure cei...

Страница 25: ...the support as per the direction of the arrow d Fasten the spherical cover by lock screws as per Figure 13 3 4 Installation of the Transparent Spherical Cover Steps of Installation 1 Align the bayone...

Страница 26: ...a Input Voltage AC24V 10 50 60 HZ Input Power Indoor 12W Outdoor 30W 1 25A Baud Rate 2400 bps 4800 bps 9600 bps 19200 bps selectable Range of Address 0 511 Communication Style RS 485 Communication Pro...