Excell YSW-5E Скачать руководство пользователя страница 1

                                                                                                 

 

                                                                                                

 

 
 
 
 
 

                      

User Manual 

Waterproof Weighing Scale 

 

YSW-5E 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 

 

 
 

© Excell Precision Limited 2015.  All rights reserved Worldwide. 

The information contained herein is the property of Excell Precision Limited and is 
supplied without liability for errors or omissions.  No part may be reproduced or used 
except as authorised by contract or other written permission.  The copyright and the 
foregoing restriction on reproduction and use extend to all media in which the 
information may be    embodied. 

 
 

Содержание YSW-5E

Страница 1: ...erein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written permissi...

Страница 2: ...d Keypad Introduction 6 1 4 Self Test Mode 8 1 5 Error Messages 9 1 6 Weight Unit 9 Chapter 2 External Function Setting 10 2 1 General Function Setting 11 2 1 1 Power Saving Function Setting 12 2 1 2...

Страница 3: ...the scale or subject the weigh pan to any strong shock loads 3 The load placed on the weigh pan must not exceed the maximum weighing capacity of the scale 4 If the scale is not going to be used for s...

Страница 4: ...g the performance of the scale 4 Remove any weight that might be on the weigh pan before the scale is switched on and avoid leaving weight on the pan for long periods of time 5 All goods weighed shoul...

Страница 5: ...3 Do not short the battery terminals to check whether there is current Please check whether the connection point is firm to guarantee good connection 4 The battery should be replaced by specialized pe...

Страница 6: ...ation duration Selectable units Kilogram kg gram g ounce oz and pound lb weighing units available Built in rechargeable battery can be easily replaced Vertical placement design battery prevents from e...

Страница 7: ...ows up The scale must be fully charged before operating again Low battery shift voltage 5 3V DC 1 3 Display and Keypad Introduction Icon Introduction 0 Zero point indication STABLE stable indication G...

Страница 8: ...the TARE key to zero the weight of the container The screen displays the 0 STABLE icon 2 Put the goods in the container the screen displays the net weight value of the goods 3 Remove the full containe...

Страница 9: ...with weight changing e Please check the backlight f Press ON ZERO key to back to the last screen the display shows KEYPAD TEST MODE c Press TARE to enter display shows Keypad s internal code TARE key...

Страница 10: ...range when switching the scale on approval models Internal value is below Zero A D IC malfunction cannot read A D value The load cell may not be connected to the scale correctly The weight of the obje...

Страница 11: ...Function setting mode The LCD shows Press UNITS key Press ON ZERO key Press UNITS key Press UNITS key Press UNITS key Press ON ZERO key Press ON ZERO key Press ON ZERO key General Function setting mod...

Страница 12: ...function setting menu ON ZERO key Upward key from 0 to 9 UNITS key Downward key from 9 to 0 TARE key Move the cursor to right NET GROSS key Move the cursor to left ACTIONS DISPLAY NOTE Return to the...

Страница 13: ...When the scale returns to zero or you do not pressing any key it will enter into power saving mode after 10 seconds Press TARE key Use ON ZERO or UNITS key to select function on or off Press TARE key...

Страница 14: ...Timer Setting Select in the General Function setting mode to change the automatic power off timer setting LED displays the last status Automatic power off function When the weight on weigh pan is les...

Страница 15: ...low limit value Press TARE key Key in the parameter setting for alarm Press TARE key LED displays the last status LED displays the last status Alarm setting a b c The definition of a b c positions a 1...

Страница 16: ...r setting External setting is not available for OIML NTEP and Sri Lanka approved models ACTIONS DISPLAY NOTE Return Cancel the restoration Restore to the default setting Press TARE key Use ON ZERO or...

Страница 17: ...ing Use ON ZERO or UNITS keys to key in the parameters Default setting 5 Parameter 0 9 the larger the number the faster the filter response Fast response can lead to weight instability Digital switch...

Страница 18: ...ximum capacity of 1st unit and the unit The digit on the right side keeps flashing The scale is calculating the internal value of the zero point After stabilization the LED shows the calibration weigh...