TECHNICAL SPECIFICATIONS
OPERATION
The
LEDMASTER CLASSIC
is a dimmer specially designed to
drive “Tunable White” equipments, composed of two light
sources: warm white and cool white.
The system allows the user to get a colour balance between
the two light sources. This balance can then be dimmed,
without drifting, in order to get the desired brightness.
SAFETY INSTRUCTIONS
Proper use:
This unit is designed to control lighting sources using
PWM commands. Use the device only in its intended use
as described in this manual. Any other use, as well as use
in other conditions, will be considered non-compliant
and can cause injury and damage. No liability will be
assumed for damages resulting from improper use.
The device should only be used by people in full
possession of their physical, sensory and mental abilities
who must have the knowledge and experience required.
All the other persons are only allowed to use the device
under the supervision or direction of a person responsible
for their safety.
Safety:
Risk of electric shock
This lighting system requires high voltage, which can
result in an electrical shock. Never remove covers. The
parts inside the device are maintenance free.
Dangers for children
Ensure a proper disposal of plastic envelopes and
packaging. They should not be near babies nor young
children: suffocation danger. Make sure that children do
not remove small parts of the unit (e.g. knobs, screws or
similar). Children could swallow the pieces and choke.
Never leave unattended children use electrical devices.
Electric shock caused by a short circuit
Do not modify the power cord nor the plug. In case of non-
compliance, there is a risk of electric shock and fire hazard
and death. If in doubt, contact a certified technician.
Eye injuries due to a high light intensity
Do not look at the beam light directly to avoid any visual
problems.
Risk of fire
Never cover the device nor its ventilation slots. Do not
install the device close to a source of heat. Keep the
device away from flames.
Terms of use
The device is designed for indoor use. To prevent
damage, do not expose the product to liquid or moisture.
Avoid direct sunlight, clogging and strong vibrations.
Power supply
Check the operation of the power supply before
connecting to the system.
Before connecting the appliance, check if the voltage
indicated on the device matches the voltage on the local
supply network and if the socket is fitted with a differential
circuit breaker. In case of non-compliance, the device
could be damaged and the user might be injured.
When a storm is announced or the unit must not be used
for an long time, unplug it to reduce the risk of electric
shock or fire.
CARE
- Unplug the unit when cleaning it and during all
maintenance operations.
- Do not use cleaning product: use a dry cloth and rub
gently.
- Store the device in a clean, dry place, away from
direct exposure from sunlight and dust.
OVERVIEW
The
LEDMASTER CLASSIC
offers a second mode of operation,
used to control independently the two output channels.
It is compatible with most of the continuous current
light sources, thanks to its wide voltage range (
5VDC to
24VDC
), and its maximum current of
2x6A
.
Power supply
The electrical power supply should be plugged-in the
XLR4 Male connector
. The polarity is described in the
following illustration:
The switch
is used to turn ON/OFF the system. When
the system is powered, the indicator
turns on.
The input voltage range is 5VDC to 24VDC. The maximum
current is 12A. The four pins have to be connected in
case the light source consumes over 6Amps.
The voltage applied at the input should be compatible
with the light source connected to the outputs.
Outputs
The outputs are located on the XLR 4 Female connector
.
The light source to drive has to be connected on this
connector.
The polarity is described in the following illustration:
Both VCC pins have to be connected in case the light
source consumes more than 6Amps.
The maximum output current is 6Amps per channel (12A total).
Modes
The mode of operation can be selected using the switch
.
The two modes are: Tunable White and Dual Channel.
Tunable White Mode
This mode is used to control the colour temperature
and the brightness of a light source composed of two
channels warm+cool white.
The rotary button
is used to adjust the balance
between the two channels. The rotary button
is used
to adjust the brightness.
The brightness adjustment does not affect the colour
balance. The adjustment of the colour balance does not
affect the brightness.
Dual channel mode
The mode is used to adjust the brightness of the two
channels independently. The first channel is controlled by
the rotary button
and the second by the rotary button
.
EXALUX est une marque déposée
de la société française LEDIXIS
EXALUX is a registered trademark of
the French Tech company LEDIXIS
1 rue de la Noë - Bat. IM3
CS 12111 | 44322 Nantes cedex 3 | FRANCE
+33 (0)9.72.45.70.43
www.exalux.eu
Information :
Support technique / Technical support :
Dernière mise à jour / Last updated on 08/2016
Содержание LEDMASTER CLASSIC
Страница 1: ...CLASSIC...