background image

GENERAL INFORMATION

This instruction manual contains important notifications regarding 

the safe use of the CONNECT-TX100.
Please take the time to read this manual carefully and thoroughly 

before installing and operating the system. 
We recommend you keep a copy for future use and you transfer it 

to the buyer if you resell the system. 
EXALUX reserves the right to modify and upgrade its range of 

products, with no obligation to integrate these changes into 

products already sold. Therefore, all the information found in this 

manual is subject to change without notice.

TECHNICAL SPECIFICATIONS

SAFETY INSTRUCTIONS

Proper use:

This unit is designed to control lighting sources using DMX 

commands. Use the device only in its intended use as described in 

this manual. Any other use, as well as use in other conditions, will be 

considered non-compliant and can cause injury and damage. No 

liability will be assumed for damages resulting from improper use.
The device should only be used by people in full possession of 

their physical, sensory and mental abilities who must have the 

knowledge and experience required. All the other persons are only 

allowed to use the device under the supervision or direction of a 

person responsible for their safety.

Safety:

Risk of electric shock

This system requires high voltage, which can result in an electrical 

shock. Never remove covers. The parts inside the device are 

maintenance free.

Dangers for children

Ensure a proper disposal of plastic envelopes and packaging. 

They should not be near babies nor young children: suffocation 

danger. Make sure that children do not remove small parts of the 

unit (e.g. knobs, screws or similar). Children could swallow the 

pieces and choke. Never leave unattended children use electrical 

devices.

Electric shock caused by a short circuit

Do not modify the power cord nor the plug. In case of non-

compliance, there is a risk of electric shock and fire hazard and 

death. If in doubt, contact a certified technician.

Risk of fire

Never cover the device nor its ventilation slots. Do not install the 

device close to a source of heat. Keep the device away from flames.

Terms of use

The device is designed for indoor use. To prevent damage, do 

not expose the product to liquid or moisture. Avoid direct sunlight, 

clogging and strong vibrations.

Power supply

Check the operation of the power supply before connecting to 

the system.

Before connecting the appliance, check if the voltage indicated 

on the device matches the voltage on the local supply network 

and if the socket is fitted with a differential circuit breaker. In case 

of non-compliance, the device could be damaged and the user 

might be injured.

When a storm is announced or the unit must not be used for an 

long time, unplug it to reduce the risk of electric shock or fire.

CARE

 

– Unplug the unit when cleaning it and during all maintenance 

operations.

 

– Do not use cleaning product: use a dry cloth and rub gently.

 

– Store the device in a clean, dry place, away from direct 

exposure from sunlight and dust.

EXALUX est une marque déposée

de la société française LEDIXIS

EXALUX is a registered trademark of

the French Tech company LEDIXIS

1 rue de la Noë - Bat. IM3

CS 12111 | 44322 Nantes cedex 3 | FRANCE

+33 (0)9.72.45.70.43

www.exalux.eu

Information :

[email protected]

Support technique / Technical support :

[email protected]

Dernière mise à jour / Last updated on 01/2017

(1)

 powerCON Connector

      Power supply

 100-240VAC

(2)

 XLR4 Connector

      Battery input 5-24VDC

(3)

 XLR5 Connector

      DMX Input

(4)

 Connect Button

(5)

 LED indicator

OVERVIEW

OPERATING PRINCIPLE

The  CONNECT-TX100   is a wireless DMX transmitter, that uses 

LumenRadio CRMX technology (2.4GHz). This system allows the 

users to control DMX enabled fixtures wirelessly, several hundred 

meters away.
CONNECT-TX100 can transmit an entire DMX universe (512 

channels) without any latency.
A complete system is composed of a CONNECT-TX100 transmitter, 

linked with one or several CONNECT-RX100 receivers, and can be 

controlled from a standard DMX controller.
Several CONNECT-TX100 + CONNECT-RX100 can be used 

simultaneously, in order to transmit several DMX universes.

POWER SUPPLY

The CONNECT-TX100 offers two power supply inputs: 

(1) 

and 

(2)

.

The first power supply input using powerCON connector 

(1) 

is an 

AC power supply (100-240 VAC 50/60Hz).
The second one, using a XLR4 connector 

(2)

, is dedicated to 

batteries with DC current between 5 and 24 Volts. Only pins 1 and 

4 are connected. Pin 1 is used for GND and pin 4 is used for +VCC  
(cf. opposite diagram).

DMX INPUT

The DMX signal to transmit should be injected in the XLR5 input 

(3)

 

of the CONNECT-TX100, respecting the standard pinout :
                Pin1: GND   |   Pin2: DMX-   |   Pin3: DMX+
The CONNECT-TX100 can transmit a single DMX universe, up to 

512 channels. The DMX signal should comply with the DMX512 or 

DMX512-A standard.
The indicator 

(5)

 provides a feedback on the DMX status :

- If no DMX signal is detected, the indicator blinks slowly.
- If a valid DMX signal is detected, the indicator remains on. The 

signal is transmitted to the linked CONNECT-RX100 receivers.

LINKING RECEIVERS

CONNECT-TX100 wirelessly transmits the DMX signal it receives.
By default, the CONNECT-RX100 receivers do not listen to 

transmitted data : it is necessary to link the receivers to the 

transmitter.
In order to link a receiver, press the button 

(4)

 on the CONNECT-

TX100. The indicator 

(5)

 will start to fastly blink for 10 seconds.

During these 10 seconds, any un-linked receivers CONNECT-RX100 

in reach will link with the CONNECT-TX100.
Once the indicator 

(5) 

stops blinking, it is no longer possible to link 

any receivers, and the systems goes back to normal operation.
The CONNECT-TX100 does not provide any feedback concerning 

the fact that one or several receivers have been linked during the 

procedure.
The linking procedure does not unlink the receivers already linked 

to the CONNECT-TX100. This procedure can be initiated has many 

times as necessary.
Several receivers CONNECT-RX100 can be linked during a single 

procedure.
During the linking procedure, the DMX signal is not transmitted.

UNLINKING RECEIVERS

At any moment, it is possible to reset the configuration of the 

CONNECT-TX100, by unlinking all the linked receivers. To do so, 

press the button 

(4)

 during 3 seconds. The indicator 

(5)

 will start 

to slowly blink during a few seconds. This means that the unlinking 

process has complete.
The CONNECT-RX100 will no longer receive the data sent by the 

CONNECT-TX100.
In order to unlink a single receiver CONNECT-RX100, refer to the 

user manual of the receiver.

LUMENRADIO COMPATIBILITY

EXALUX recommands the use of the receivers CONNECT-RX100. 

Nevertheless, the CONNECT-TX100 can be used with any receiver 

compatible with CRMX Technology from LumenRadio.
For more information, refer to www.lumenradio.com.

To provide supply to the CONNECT-

TX100, one of these two connectors 

has to be connected to an adapted 

power supply. If both power supplies are 

connected at the same time, only AC 

power supply connected to powerCON 

connector 

(1) 

will be used.