EFC™  

ELECTRONIC FLOW CONTROL FOR COMPRESSED AIR 

INSTALLATION AND MAINTENANCE

 

 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

THE EFC SHOULD NOT BE USED IN AN EXPLOSIVE OR FLAMMABLE AREA. PROTECTION PROVIDED BY 
THE EQUIPMENT MAY BE IMPAIRED IF USED WITH ACCESSORIES NOT PROVIDED OR RECOMMENDED 
BY EXAIR, OR IS USED IN A MANNER NOT SPECIFIED BY EXAIR CORPORATION. 

 
EXAIR’s EFC is an electronic flow control for compressed air that provides precise “on/off” timing control of the compressed air 
supplied to the EXAIR products. The EFC permits the critical timing adjustment needed to operate the EXAIR products as 
efficiently as possible, turning on the compressed air only when it is needed. This control system provides flexibility by sensing 
distance as well as providing numerous valve operating modes and timing delays. The EFC is applicable to many different 
manufacturing lines and environments. The sensor is compact which makes it simple to install in tight spaces. The polycarbonate 
enclosure of the EFC control is NEMA 4/IP56 rated which is ideal for wet locations.  

 

INSTALLATION 

1.

 Install EXAIR’s engineered airflow product(s) such as the Super Air Knife, Air Amplifier, Air Nozzles, etc., following the 

“Installation and Maintenance Sheet” that was included with that product.  

 

2.

 Connect the compressed air supply to the EFC solenoid valve, paying attention to the flow direction arrow on the brass valve 

body (in and out). The solenoid valve should be located downstream from a filter and before the compressed air product. For 
ease of connecting the solenoid valve to the compressed air pipe, the electrical coil can be detached from the valve body by 
using a flat blade screwdriver to remove the metal clip that holds the coil to the valve body. Connect the compressed air line to 
the EXAIR product(s) and re-install the electrical coil, securing it to the valve using the clip. 

 

3.

 Prior to the electrical hook up, install the EFC timer control in a location that is convenient for adjustment of the timer settings. 

Do not permanently wire the EFC. Do not position the EFC in a space where it is difficult to disconnect the power cord. It 
should not be mounted in direct sunlight. Always consider the best location that is convenient for the installation of piping air 
to the EXAIR product as well as connecting the unit to a power source. To access the mounting holes of the EFC timer control 
box, remove the cover by turning the four screws counter-clockwise. The mounting holes are the same as those used for the 
cover screws. It is recommended that all four holes be used (if possible) for a secure mounting that will minimize breakage. 
Four mounting tabs which attach to the back of the enclosure with screws can also be used.

 

 

11510 Goldcoast Drive 

 Cincinnati, OH, USA 45249-1621 

(513) 671-3322 

 FAX (513) 671-3363 

 E-mail: [email protected] 

Symbol

 

Publication

 

Description

 

 

IEC 60417-5019

 

Protective Conductor 
Terminal (Safety Ground)

 

 

IEC 5009

 

Stand-by Power Symbol

 

Power Supply Input:

  

100V-240 VAC, 50/60 Hz, 
0.25-0.45A 

Power Supply Output (to 
sensor):

 24VDC at .65A 

Sensor:

 12-24VDC input, 

consumes 30 mA 

Sensing Range:

 Diffuse retro-

reflective to 1 meter 

Enclosure Rating:

 NEMA 4, 

IP56 

Temperature Rating:

 13°F to 

131°F (-25°C to 55°C) 

Model 9055

  

(for up to 40 SCFM) 

Model 9056

  

(for up to 100 SCFM) 

Model 9057

  

(for up to 200 SCFM) 

Model 9064

  

(for up to 350 SCFM) 

 