UVC Air Sanitizer 

V-Lab300E-LT 

 

 

 

 

Manual Version 1.2 

Date 

Revision No. 

Author 

Checked 

Description 

04.11.2020 

1.0 

DRD 

TSN/TNR 

Version 1.0 

12.11.2020 

1.1 

DRD 

TSN 

Changes in Chapter 6 and 8 

30.11.2020 

1.2 

TSN 

DRD 

Version 1.2 

13.04.2021 

1.3 

TNR 

        GJN 

Additions 

 

 

 

 

 

 

 

 

 

Contact 

Tel.: +49 2204 9485 30 
E-Mail: [email protected] 
Web: www.exactsolutions.de 

 

 

Содержание V-Lab300E

Страница 1: ...Author Checked Description 04 11 2020 1 0 DRD TSN TNR Version 1 0 12 11 2020 1 1 DRD TSN Changes in Chapter 6 and 8 30 11 2020 1 2 TSN DRD Version 1 2 13 04 2021 1 3 TNR GJN Additions Contact Tel 49 2...

Страница 2: ...3 5 2 Specifications 13 5 3 Airflow 13 6 Setup and operation 14 6 1 Notes on installation and operation 14 6 2 Positioning and dimensioning 15 6 3 Mechanical setup 16 6 4 Electrical setup 20 6 5 Opera...

Страница 3: ...veloped and manufactured with the highest care and attention However improper handling can cause a risk for safety and or damage Read these instructions carefully before handling and installing the pr...

Страница 4: ...ned electrician Follow the local laws and regulations Warning UVC radiation open the housing only when the device is disconnected from mains power UVC harms within a very short time eyes and skin Neve...

Страница 5: ...he case of improper behaviour and if necessary has been trained Qualified Specialised person A person can be considered qualified or specialised when based on specialised training knowledge and experi...

Страница 6: ...l shock fire malfunction or deformation may occur Keep the packing anti moisture material or vinyl packing out of the reach of children This material is harmful if swallowed Vinyl packing can cause su...

Страница 7: ...parts or the whole system may fall down Protection objective prevent personal injury or property damage Only use correct mounting material such as screws screw anchor etc depending on the given circu...

Страница 8: ...might be exposed and leave the housing This endangers all surrounding persons If the housing is damaged the product shall no longer be operated Qualified persons should disconnect the device from powe...

Страница 9: ...er might be situated on the metal housing Persons who touch the housing or directly the damaged cable might get electrocuted This endangers all persons who might touch the product Risk of injury produ...

Страница 10: ...Manual UVC Air Sanitizer V Lab300E LT 30 11 2020 Page 10 of 34 Please notice that the mass centre is not in the middle of the units Please observe this while handling...

Страница 11: ...sed in the product V Lab300E LT can be ordered under the following model number UVC light source Type UVpro K40 4 4 2 Floor Stand with wheels Model number ASZ FSW 300 The ASZ FSW 300 floor stand with...

Страница 12: ...redominant and biologically weighted UV radiation intensity and determines the maximum permissible exposure time of the skin and eyes Bring the sensor to the source of radiation the maximum length of...

Страница 13: ...ction depends largely on the installation and positioning We or our partners would be happy to advise you if you have any questions 5 2 Specifications Parameter Value UVpro tubes 2 x 41 W Total UVC ou...

Страница 14: ...handling of the devices must be carried out by at least two people Wear rubberised gloves to safely hold the unit Wear safety shoes Additional people may have to be included in the installation proces...

Страница 15: ...nstalled in such a way that the air outlet points towards the main part of the room For multiple Air Sanitizers these should be uniformly distributed in the room Inlets and outlets should always be fr...

Страница 16: ...tion on a wall is not correct serious accidents can occur The arrow on the mounting bracket must point upwards when mounted on a wall in vertical orientation WARNING If the ceiling or wall are not sta...

Страница 17: ...moving the 2 pcs M4x8 lens head screw Figure 5 and slide the bracket into the indicated direction There are four bolts that will slide out of the corresponding notch Make sure the 4 bolts slide out th...

Страница 18: ...ween bracket and supporting structure mount it without the washers 5 If necessary e g for a customised power connection the two covers can be removed Figure 8 Use an adequate tool like an angle grinde...

Страница 19: ...ice on the bracket make sure the 4 bolts slide into the notches of the mounting bracket Figure 9 7 Secure the device with the two M4x8 lens head screws Figure 5 8 Make sure that the four M4x8 lens hea...

Страница 20: ...a protective grounding and may only be connected to circuits that are protected by a Residual Current Device RCD Therefore always connect the corresponding PE Protection Earth cable WARNING Always use...

Страница 21: ...relief Figure 13 Figure 13 Mounting pull relief 4 Mount the bracket chapter 6 3 mount the device plug in the power connector and switch the device on 5 Make sure to always insert the wire protection...

Страница 22: ...working correctly by checking whether the fans are turning and whether you can feel a flow of air A regular visual inspection of the quartz tube and the reflectors for dust and deposits should be car...

Страница 23: ...higher qualifications WARNING Do not replace defective or faulty parts with parts that have not been approved by the manufacturer This can lead to serious injuries and property damage WARNING Mainten...

Страница 24: ...replacement tube the fault is in the tube We would be happy to exchange this tube for you free of charge The tube service life has been exceeded the tube must be replaced The UVpro tube no longer ign...

Страница 25: ...he manufacturer When do the UVpro tubes have to be cleaned Dirt such as dust grease or soot significantly reduces the UVC output Regular checking the device and fixed cleaning intervals are recommende...

Страница 26: ...1 Life time of UVC tubes UVC tubes have a limited life time They are subject to a continuous aging process The life time of the UVC tubes is 12 000 hours under normal operating conditions power drop 2...

Страница 27: ...ll relief of the power cable and disconnect the cables from the connecting clamps See also chapter 6 Setup and operation Figure 15 Removing pull relief 3 Open the backside by removing the 18 pcs of M4...

Страница 28: ...ding clamp Figure 18 Reference image showing holding clamp at ceramic end of UVC tube 5 Carefully cut the cable tie at the holding clamp Figure 19 Cutting the cable tie 6 Gently remove the coupling nu...

Страница 29: ...oth and replace them if damaged 7 1 3 Installing new Tubes 1 Carefully place the rubber seal followed by the coupling nut over the new tube 2 Gently place the tube with its connector to the socket In...

Страница 30: ...the cable tie at the holding clamp Figure 24 Position cable tie at holding clamp 6 Reinstall the back cover and the power connection Gently tighten the screws by hand tool WARNING Never switch on the...

Страница 31: ...efective tubes 8 2 Electronical components The electronic ballast and the other electronical components can be recycled via the waste electrical equipment disposal 8 3 Steel parts and packaging All st...

Страница 32: ...Manual UVC Air Sanitizer V Lab300E LT 30 11 2020 Page 32 of 34 9 Mechanical Drawing...

Страница 33: ...Manual UVC Air Sanitizer V Lab300E LT 30 11 2020 Page 33 of 34 10 Declaration of conformity...

Страница 34: ...UVC Air Sanitizer V Lab300E LT 30 11 2020 Page 34 of 34 Imprint EXACT solutions GmbH Lustheide 85 51427 Bergisch Gladbach GERMANY Tel 49 2204 9485 30 E Mail info exactsolutions de Web www exactsoluti...

Отзывы: