Ex-Or LS1000R Скачать руководство пользователя страница 1

PACK CONTENTS

REQUIRED

MOUNTING/ INSTALLATION STEPS

x1

x1

x1

x1

x1

x1

x1

x1

x1

x1

x2

M4 x 14mm

(For Euro conduit box 

installation)

M3 x 20mm

(For ceiling mout 

installation)

Hole saw size:

Ф75mm - 80mm

M3 x 15mm

(For cable clamps 

installation)

x2

x4

Surface Mount

1

4

2

5

3

6

7

9

8

I

 5mm

4mm

No 2 

Phillips

3mm

0FF

230V

ij

 5mm

50.8mm or 60mm

60mm

50.8mm

CAUTION:

OR

OR

‘CLICK’

‘CLICK’

‘CLICK’

Switch OFF the electricity at the fuse box by 

removing the relevant fuse or switching off the circuit 

breaker before proceeding with the installation.

IMPORTANT

L1

L2

L

N

Wiring diagram 

Connect the mains supply 

cable to the terminal block on 

the backplate as follows.

Connect the cable from the 

lighting load to the terminal block 

on the backplate as follows. 

Note: Remove the external link 

between L and L2

( See connection diagram )

Option1

Connection:

L

N

Live

Brown

L1

Switched Live

White

Neutral

Blue

Earth

Green / Yellow

L

N

Live

Brown

L1 &

L2

Relay contact 

for external load 

White

Neutral

Blue

Earth

Green / Yellow

The device needs 
20-50 seconds to 

warm up.

x2

x2

1 x 2.5mm²

Cable entry 

capability at

terminal block

2 x 1.0mm²
2 x 1.5mm²

Cut out

here

N

N L

μ

L2 L1

L

Option2

* Remark: L1 & L2 is relay output

N

N L L2 L1

L

L1

L2

μ

LS1000R LightSpot 360° Dual Mount PIR installation and operating instructions

Only suitably qualified personnel should install this equipment

!!

Haydock Lane
Haydock
Merseyside
WA11 9UJ
UK
www.ex-or.com 

Technical Support 
+44 (0)1942 719229

WALK TESTING

1

3

Activate Manual Override Operation

MANUAL OVERRIDE OPERATION

SWITCHABLE LOAD

TECHNICAL SPECIFICATIONS

Detection Range:

Detection Angle:
Power Supply: 
Maximum Switchable Load:

Time On Adjustment:
Dusk Level Adjustment:
Operating temperature:
Environment Protection:

Up to 6 metres diameter (3m Radius)
at mounting height of 2.5m
360°
220 ~ 240 VAC / 50 Hz
Max load current 6A
Incandescent / Halogen Max 2000W
Flourescent lamp (magnetic) Max 500W
Flourescent lamp (electronic ballast) Max 400W
Low energy (CFL) Max 120W
LED lamp Max 110W
Fan Max 75W
5 seconds - 15 minutes
Day & night or night only operation
-20 to 40°C
For ceiling mount - IP44
For flush mount - IP44 (at sensor portion only)
 

     - IP20 (ceiling board onwards)

Max 400W

Max 500W

Max 2000W

Max 120W

Max 110W

Max 75W

2

MIN. SUN.

warm up

20-50 SEC

Around

10 second

Lamp turn on
when reach Lux
setting level.

ON

OFF

ON

2 times within 2 seconds

DUSK

DAWN

Hrs

2 SEC

5

SEC

1

Deactivate Manual Override Operation

Manual deactivation before dawn

2

Auto deactivation when
dusk to dawn

ON

Lamp turn off when 

dusk to dawn.

OFF

ON

1 time within 1 second

1 SEC

5

SEC

OR

Auto Mode

Auto Mode

ON